Schneider Electric

Choose a subcategory:
Show all categories

mccb ns800n

  • Degree of protection: IP40
  • Resistance to impacts: IK07
  • Vibration resistance: Class 3
  • Operating temperature range: -25°C to +70°C
  • Storage temperature: -40°C to +80°C

mccb nsx250f

  • Frequency: 50/60 Hz
  • Maximum operating temperature: 40°C
  • Minimum ambient temperature: -25°C

Modicon Standard Unmanaged Switch

micrologic 2.3 400a

  • Rated voltage: 400 V AC
  • Frequency: 50/60 Hz
  • Maximum switching capacity: 4000 А
  • Maximum short-circuit current resistance: 50 kA
  • Degree of protection: IP20

compact ns 1250

  • Maximum switching capacity: up to 50 kA
  • Degree of protection: IP40
  • Insulation class: IEC 60947-2: 1
  • Resistance to short-circuit currents: 10 Icn

ns1250n micrologic 2.0

  • Frequency: 50/60 Hz
  • Degree of protection against short circuit: 3 (IEC 60947-2)
  • Mechanical wear resistance: 10,000 on/off cycles
  • Electrical wear resistance: 2,000 on/off cycles at maximum current

ns160 schneider

  • Nominal working endurance: Up to 400A (depending on the model)
  • Short-circuit withstand limit: Up to 6 kA (depending on the model)
  • Degree of protection: IP40, IP54 (depending on the model)
  • Operating temperature range: -25°C to +70°C

ns160h schneider

  • Vibration resistance: 3 g/10 Hz
  • Shock resistance: 50 g/11 ms
  • Ambient temperature: -25°C to +70°C

schneider ns160n

  • Terminal size: 10 mm² (copper)
  • Maximum cable diameter: 25 mm² (copper)
  • Type of terminals: Screw

schneider ns400n

  • Rated mechanical endurance: 10,000 on/off cycles
  • Electrical switching wear resistance: 2500 on/off cycles at short-circuit current
  • Maximum switching capacity: 50 kA
  • Degree of protection: IP40
  • Permissible ambient temperature: -25°C...+70°C (for fixed installation)

schneider ns800n micrologic 2.0

  • Frequency: 50/60 Hz
  • Thermal current limit: 1000 А
  • Class of the disconnector: LSI

ns800n micrologic 5.0

  • Rated operating power: up to 550 kW
  • Rated switching capacity: up to 2200 kVA
  • Thermal current limit: up to 1000 A
  • Short-circuit current: up to 50 kA
  • Maximum withstand voltage: 8 kV
  • Response time: from 0.05 to 0.3 s (adjustable)

schneider nsx100h

  • Ambient temperature: -25°C to +50°C
  • Relative humidity: up to 95% (non-condensing)
  • Vibration: vibration resistant according to IEC 60068-2-6


nsx 125a

  • Control type: Manual
  • Control mechanism: Lever
  • Indication: Flag position indicator
  • Auxiliary contacts: 2 NO + 2 NC (optional)
  • Signal contacts: 1 NO + 1 NC (optional)
  • Motor drive: Yes (optional)

nsx 160 n

  • Maximum operating voltage: 750 V AC 50/60 Hz
  • Maximum current: 175 А
  • Short-term current withstand: 1600 А
  • Mechanical wear resistance: 10,000 WO cycles

nsx 160na

  • Power source: Internal, alternating current
  • Energy consumption: Up to 350 W
  • Size: 1U
  • Operating temperature: 0°C to +50°C
  • Humidity: 0% to 95% (non-condensing)

nsx 160a

  • Rated insulation voltage: 800 V AC
  • Overcurrent control current range of the overload disconnector: 63-160 А
  • Short-circuit sensitivity limit: 36 kA

nsx 160f

  • Rated insulation voltage (Ui): 800 V AC
  • Rated operating voltage (Ue): 690 V AC
  • Heat resistance limit: 120°C
  • Rated short-circuit current (Icu): 36 kA

nsx 200a

  • Rated breaking capacity (Icu): 10 kA at 400 VAC
  • Peak breaking capacity (Icu): 20 kA at 400 VAC
  • Current limit characteristic (Ics): 12 kA at 400 VAC

nsx 250a

Operating voltage:

  • AC: 415 V (phase-neutral), 690 V (phase-to-phase)
  • DC: 220 V

schneider nsx250n

  • Rated voltage: 415 V AC
  • Frequency: 50 Hz
  • Electromagnetic compatibility: IEC/EN 61000-6-1, IEC/EN 61000-6-3
  • Resistance to short-circuit currents: 50 kA (symmetrical)

nsx 400a schneider

  • Rated voltage: 400 V AC / 690 V DC
  • Frequency: 50/60 Hz
  • Short circuit current limit: 18 kA
  • Peak short-circuit current: 50 kA
  • Operating frequency: 0.5 Hz
  • Electrical wear resistance: CO 6,000

nsx 63a

  • Operating temperature range: from -25°C to +50°C
  • Vibration resistance: according to IEC 60068-2-6
  • Impact resistance: according to IEC 60068-2-7

nsx 800a

  • Operating temperature range: -25°C to +70°C
  • Vibration resistance: Up to 10 GN/m2
  • Impact resistance: 15 J
  • Compliance with standards: IEC 60947-2, GB 14048.1

nsx 80a

  • Rated voltage: 230/400 V AC
  • Overload class: 3
  • Degree of protection: IP40

nsx mccb

  • Ambient temperature: -25°C to +55°C
  • Altitude above sea level: up to 2000 m
  • Vibration and shock resistance
  • Resistance to electromagnetic interference (EMI)

nsx100 micrologic 2.2

  • Rated voltage: 230/400 V AC
  • Rated frequency: 50/60 Hz
  • Thermal decoupling limit: 1.1 In - 1.35 In
  • Short-circuit current limit: 3 ... 14 x In (short-term)
  • Electromagnetic release limit: 50 ... 100 x In (instantaneous)
  • Power loss: < 0.7 W (at rated current)
  • Degree of protection: IP40

nsx100b tm100d

  • Operating temperature range: -25°C to +55°C
  • Storage temperature: -40°C to +70°C
  • Mounting: on a DIN rail or panel

nsx100b tm63d

  • Short-circuit current limit (Icu): 100 kA
  • Thermal overcurrent limit (Ith): 63 А
  • Dynamic sustained short-circuit current limit (Ics): 65 kA

nsx100b tm80d

  • Ambient temperature: -25°C to +50°C
  • Vibration resistance: up to 3 GHz
  • Impact resistance: up to 15 G (IEC 60068-2-7)
  • Mounting: On DIN rail or panel