Schneider Electric
Choose a subcategory:
Show all categories
schneider nsx100f
- Rated operating frequency: 50/60 Hz
- Thermal release limit: 85°C
- Operating temperature limit: -25°C to +70°C
- Storage temperature limit: -40°C to +80°C
- Electrical resistance: 500 V AC/DC
- Mechanical resistance: withstands shocks up to 7 g
nsx100f 100a
- Rated operating frequency: 50/60 Hz
- Short-circuit current limit (Icu): 1 kA
- Short-circuit current limit (Ics): 36 kA
- Rated power: 22 kW (AC-1) / 44 kW (AC-3)
nsx100f 3p
- Rated operating frequency: 50/60 Hz
- Resistance to short-circuit currents: 36 kA (at 415 V AC)
- Maximum power loss: 23 W (at 100 A)
- Insulation voltage: 800 V AC
nsx100f 40a
- Maximum short-circuit current (Icu): 36 kA
- Limit short-circuit current (Ics): 150% Icu for 0.5 s
- Thermal disconnection current: 50 А
- Rated voltage: 400 V AC
- Frequency: 50/60 Hz
- Voltage drop: 0.75% at rated current
- Switching class: AC-2, AC-3, DC
nsx100f 4p
- Thermal disconnection class: A
- Maximum permissible ambient temperature: +40°C
- Short-circuit current resistance: 10 kA at 600 VAC (IEC 60947-2)
nsx100f 63a
- Frequency: 50/60 Hz
- Maximum operating temperature: 40°C
- Minimum operating temperature: -25°C
- Maximum mechanical endurance: 1000 impacts/hour, 15 g
nsx100f mccb
- Type of disconnection mechanism: two-contact, double break
- Disconnection speed: 200 ms (typical)
- Connection speed: 150 ms (typical)
nsx100f micrologic 2.2
- Frequency: 50/60 Hz
- Thermal decoupling limit: From 1.05 to 1.3 In (depending on the model)
- Short circuit current limit: 3.5 In (depending on the model)
nsx100f tm100d
- Degree of protection: IP40
- Vibration resistance: 3 g/mm (5 Hz - 300 Hz)
- Impact resistance: 50 g/mm (11 ms)
nsx100f tm16d
- Insulation: 2000 V between channels
- Vibration resistance: 5 g (10 Hz - 500 Hz)
- Shock resistance: 50 g/0.5 ms
- Mounting: on DIN rail or panel
nsx100f tm25d
- Vibration resistance: 5 g (up to 2 GHz)
- Shock resistance: 8 g (11 ms)
- Resistance to electromagnetic interference: IEC 60947-2
nsx100f tm32d
- Rated maximum current capacity (Ics): 11 kA at 525 V AC
- Rated permissible impulse current (Ipf): 8 kA
- Rated short-circuit current (Icu): 36 kA
nsx100f tm40d
- Maximum overload current (Imax): 56 А
- Short-term withstand current (Icw): 1000 А
- Short circuit current limit (Icu): 36 kA
- Operating frequency: 50/60 Hz
nsx100f tm50d
- Rated voltage: 690 V AC
- Frequency: 50/60 Hz
- Resistance to switching overvoltages: 8 kV
- Operating temperature: -25°C to +50°C
- Storage temperature: -40°C to +70°C
nsx100f tm63d
- Maximum short-circuit current withstand (Icu): 36 kA
- Peak short-circuit current withstand (Ipk): 144 kA
nsx100f tm80d
- Rated voltage: 690 V AC (50/60 Hz)
- Maximum voltage: 8 kV
- Degree of protection: IP40
nsx100h micrologic 2.2
- Resistance to vibrations: Class 3
- Resistance to shocks: Class 2
- Operating temperature range: -25°C to +55°C
schneider nsx100n
- Rated operating frequency: 50/60 Hz
- Maximum withstand short-circuit power (Icu): 100 kA
- Rated power loss: 3.5 W to 55 W, depending on the model
- Supply voltage for auxiliary circuits: 24 VDC or 230 VAC
nsx100n 3p
- Rated operating frequency: 50/60 Hz
- Short circuit current limit (Icu): 50 kA (at 415 VAC)
- Thermal disconnection current limit (Ith): 1.31 * In (rated current)
- Cold resistance current limit: 12 In (rated current)
- Rated power loss: 10 W (at rated current)
nsx100n 4p
- Rated current of the thermal disconnector: 100 А
- Rated current of the electromagnetic recloser: 1000 А
- Rated power loss per pole: 1.3 W
- Degree of protection: IP40
nsx100n tm100d
- Rated operating frequency: 50/60 Hz
- Maximum operating voltage: 440 V AC
- Insulation limit voltage: 690 V AC
- Mechanical wear resistance: 10,000 on/off cycles
- Electrical wear resistance: 2000 on/off cycles at short-circuit current
nsx100n tm63d
- Rated operating voltage (Ue): 690 V AC 50/60 Hz
- Maximum operating voltage (Umax): 720 V AC 50/60 Hz
- Rated operating frequency: 50/60 Hz
- Maximum power loss: 10 W
25 kA at 415 VAC, 3 poles 3d, TMD trip unit 125 A
25 kA (415 VAC), ComPact NSX160B, TMD trip unit 160 A, 3 poles, 3d
nsx160f 125a
Rated operating frequency: 50/60 Hz
Current control limit of the thermal disconnector: 0.5 - 1.25 In
Current control limit of the electromagnetic release: 3 - 12 In
nsx160f 160a
- Rated operating frequency: DC
- Heating limit: 85°C
- Electrical wear resistance: CO, CE
- Operating temperature range: -25°C to +70°C
- Storage temperature: -40°C to +80°C
nsx160f ma150
- Short circuit current limit (Icu): 36 kA
- Operating frequency: 50/60 Hz
- Maximum switching voltage: 690 В
- Mechanical resistance: 12 mechanical on/off cycles
schneider electric nsx250b
- Operating temperature range: From -25°C to +55°C
- Vibration resistance: Meets the requirements of IEC 60068-2-6
- Impact resistance: Meets the requirements of IEC 60068-2-7
nsx250b micrologic 2.2
- Mounting: DIN rail or panel
- Vibration resistance: 3g/10 Hz
- Impact resistance: 50g/11ms
nsx250b tm250d
- Operating temperature range: -25°C...+70°C
- Vibration resistance: according to IEC 60068-2-6
- Impact resistance: according to IEC 60068-2-7
- Electrical resistance: according to IEC 60947-2