Maximum braking power | 160 kW |
Product compatibility | Variable speed drive ATV930 without braking chopper 160 kW 380...480 V Variable speed drive ATV930 without braking chopper 130 kW 380...480 V Variable speed drive ATV930 without braking chopper 110 kW 380...480 V |
Thermal losses | 400 W |
Activation threshold | 780 V DC +/- 1 % |
Permanent braking power | 100 kW (at constant power and at engage threshold) |
Maximum braking power | 80 kW |
Product compatibility | Variable speed drive ATV930 without braking chopper 75 kW 200...240 V Variable speed drive ATV930 without braking chopper 55 kW 200...240 V |
Thermal losses | 400 W |
Activation threshold | 395 V DC +/- 1 % |
Permanent braking power | 60 kW (at constant power and at engage threshold) |
[Us] rated supply voltage | 380...480 V (+/- 10 %) |
Network frequency | 50/60 Hz |
Rated power in W | 120 kW |
Range compatibility | Altivar 61 Altivar 71 |
Product specific application | Component of the Active Front End Energy regeneration Low harmonics |
[Us] rated supply voltage | 380...480 V (+/- 10 %) |
Network frequency | 50/60 Hz |
Rated power in W | 145 kW |
Range compatibility | Altivar 61 Altivar 71 |
Product specific application | Component of the Active Front End Energy regeneration Low harmonics |
[Us] rated supply voltage | 380...480 V (+/- 10 %) |
Network frequency | 50/60 Hz |
Rated power in W | 175 kW |
Range compatibility | Altivar 61 Altivar 71 |
Product specific application | Component of the Active Front End Energy regeneration Low harmonics |
[Us] rated supply voltage | 380...480 V (+/- 10 %) |
Network frequency | 50/60 Hz |
Rated power in W | 275 kW |
Range compatibility | Altivar 61 Altivar 71 |
Product specific application | Component of the Active Front End Energy regeneration Low harmonics |
[Us] rated supply voltage | 380...480 V (+/- 10 %) |
Network frequency | 50/60 Hz |
Rated power in W | 340 kW |
Range compatibility | Altivar 61 Altivar 71 |
Product specific application | Component of the Active Front End Energy regeneration Low harmonics |
[Us] rated supply voltage | 380...440 V (+/- 10 %) |
Network frequency | 50/60 Hz |
Rated power in W | 430 kW |
Range compatibility | Altivar 61 Altivar 71 |
Product specific application | Component of the Active Front End Energy regeneration Low harmonics |
[Us] rated supply voltage | 380...440 V (+/- 10 %) |
Network frequency | 50/60 Hz |
Rated power in W | 540 kW |
Range compatibility | Altivar 61 Altivar 71 |
Product specific application | Component of the Active Front End Energy regeneration Low harmonics |
Network number of phases | 3 phases |
[Us] rated supply voltage | 380...480 V (+/- 10 %) |
Network frequency | 50/60 Hz |
Range compatibility | Altivar 61 Altivar 71 |
Product specific application | Component of the Active Front End |
Network number of phases | 3 phases |
[Us] rated supply voltage | 380...480 V (+/- 10 %) |
Network frequency | 50/60 Hz |
Range compatibility | Altivar 61 Altivar 71 |
Product specific application | Component of the Active Front End |
Network number of phases | 3 phases |
[Us] rated supply voltage | 500...690 V (+/- 10 %) |
Network frequency | 50/60 Hz |
Range compatibility | Altivar 61 Altivar 71 |
Product specific application | Component of the Active Front End |
Network number of phases | 3 phases |
[Us] rated supply voltage | 380...480 V (+/- 10 %) |
Network frequency | 50/60 Hz |
Range compatibility | Altivar 61 Altivar 71 |
Product specific application | Component of the Active Front End |
Network number of phases | 3 phases |
[Us] rated supply voltage | 380...480 V (+/- 10 %) |
Network frequency | 50/60 Hz |
Range compatibility | Altivar 61 Altivar 71 |
Product specific application | Component of the Active Front End |
[Us] rated supply voltage | 500...690 V (+/- 10 %) |
Network frequency | 50/60 Hz |
Rated power in W | 145 kW |
Range compatibility | Altivar 61 Altivar 71 |
Product specific application | Component of the Active Front End Energy regeneration Low harmonics |
[Us] rated supply voltage | 500...690 V (+/- 10 %) |
Network frequency | 50/60 Hz |
Rated power in W | 275 kW |
Range compatibility | Altivar 61 Altivar 71 |
Product specific application | Component of the Active Front End Energy regeneration Low harmonics |
[Us] rated supply voltage | 500...690 V (+/- 10 %) |
Network frequency | 50/60 Hz |
Rated power in W | 340 kW |
Range compatibility | Altivar 61 Altivar 71 |
Product specific application | Component of the Active Front End Energy regeneration Low harmonics |
[Us] rated supply voltage | 500...690 V (+/- 10 %) |
Network frequency | 50/60 Hz |
Rated power in W | 430 kW |
Range compatibility | Altivar 61 Altivar 71 |
Product specific application | Component of the Active Front End Energy regeneration Low harmonics |
[Us] rated supply voltage | 500...690 V (+/- 10 %) |
Network frequency | 50/60 Hz |
Rated power in W | 860 kW |
Range compatibility | Altivar 61 Altivar 71 |
Product specific application | Component of the Active Front End Energy regeneration Low harmonics |
Product compatibility | ATV71HC11Y...ATV71HC63Y ATV61HC11Y...ATV61HC80Y ATV71H075N4...ATV71HC50N4 ATV61H075N4...ATV61HC63N4 |
Accessory / separate part destination | Altivar speed drive in combination with Altivar AFE and fieldbus option card |
Product specific application | To communicate to further fieldbuses |
Range compatibility | Altivar Active Front End |
Height | 200 mm |
[Us] rated supply voltage | 480 V (+/- 10 %) |
Network frequency | 50/60 Hz |
Rated power in W | 240 kW |
Range compatibility | Altivar 61 Altivar 71 |
Product specific application | Component of the Active Front End Energy regeneration Low harmonics |
Ohmic value | 10 Ohm |
Continuous power | 400 W |
Cable length | 3 m |
Energy peak | 13.3 J at 230 V 7300 J at 400 V 7700 J at 480 V |
Protection type | Thermal protection via the servo drive |
Ohmic value | 27 Ohm |
Continuous power | 200 W |
Cable length | 0.75 m |
Energy peak | 4300 J at 480 V 4900 J at 400 V 7400 J at 230 V |
Protection type | Thermal protection via the servo drive |
Ohmic value | 27 Ohm |
Continuous power | 400 W |
Cable length | 0.75 m |
Energy peak | 10.5 J at 480 V 11.4 J at 400 V 18.1 J at 230 V |
Protection type | Thermal protection via the servo drive |
Ohmic value | 27 Ohm |
Continuous power | 400 W |
Cable length | 2 m |
Energy peak | 10.5 J at 480 V 11.4 J at 400 V 18.1 J at 230 V |
Protection type | Thermal protection via the servo drive |
Product compatibility | ATV32HU11M2 ATV32HU15M2 |
Ohmic value | 72 Ohm |
Continuous power | 100 W |
Average power available | 25 W at 50 В°C |
Cable length | 0.75 m |
Product compatibility | ATV32HU11M2 ATV32HU15M2 |
Ohmic value | 72 Ohm |
Continuous power | 100 W |
Average power available | 25 W at 50 В°C |
Cable length | 3 m |
200 W, 72 Ohm
Ohmic value | 72 Ohm |
Continuous power | 400 W |
Cable length | 0.75 m |
Energy peak | 15.5 J at 480 V 16.2 J at 400 V 24.7 J at 230 V |
Protection type | Thermal protection via the servo drive |
Ohmic value | 72 Ohm |
Continuous power | 400 W |
Cable length | 2 m |
Energy peak | 15.5 J at 480 V 16.2 J at 400 V 24.7 J at 230 V |
Protection type | Thermal protection via the servo drive |