Siemens SITRANS FUS Ultrasonic Flow Meters

SITRANS F US SONOFLO SONO 3100 2-TRACK . DN400 / 16 INCH, QN=3600M3/H EN1092-1 PN25 CARBON STEEL. EN 1.0345 P235GH, PAINTED. IP68 SS HOUSING, PN40, O-RING, 50MM, 200DEG.C. CABLE GLANDS, M20 IN TRANSDUCERS AND M25 / M20 / M16 IN FUS060 TRANSMITTER. SITRANS FUS060 TRANSMITTER FOR REMOTE CONNECTION. SUPPLY: 115-230 V AC 50/60 HZ. HART, 4-20MA, ACTIVE OR PASSIVE PULSE, RELAY. TRANSDUCER CABLE: 4 3 METER, MAX. 70DEG.C"

SITRANS FUE380 HYDROMETER DN100 CARBON STEEL, EN 1434 QP=60M3/H. QS=180M3/H. QI=1.2M3/H. EN1092-1 PN16 REMOTE VERSION, TRANSDUCER CABLE: 4 5 METER WITH GLAND. DN50 TO DN80: MAX. 150 DEG.C. DN100 TO DN800: MAX. 200 DEG.C. WITHOUT APPROVAL (NEUTRAL). SELECTABLE PULSE OUTPUT. PULSE VALUE: 10 L/P SITRANS FUE080 IP67 PA, SUPPLY: 115-230V AC, WITH LITHIUM BATTERY BACKUP. NEUTRAL, NO TYPE APPROVAL PULSE WIDTH: 5 MS"

SITRANS FUE380 HYDROMETER DN125 CARBON STEEL, EN 1434 QP=100M3/H. QS=280M3/H. QI=2M3/H. EN1092-1 PN16 REMOTE VERSION, TRANSDUCER CABLE: 4 5 METER WITH GLAND. DN50 TO DN80: MAX. 150 DEG.C. DN100 TO DN800: MAX. 200 DEG.C. WITHOUT APPROVAL (NEUTRAL). SELECTABLE PULSE OUTPUT. PULSE VALUE: 10 L/P SITRANS FUE080 IP67 PA, SUPPLY: 115-230V AC, WITH LITHIUM BATTERY BACKUP. NEUTRAL, NO TYPE APPROVAL PULSE WIDTH: 5 MS"

The Product is not Available now!

Check the Price with the manager.

  • flanged design
  • diameter DN 15 to DN 300 (1/2" to 12")
  • wafer design
  • diameter DN 2 to DN 100 (1/12" to 4")
SITRANS F US SONOFLO SONO 3100 2-TRACK . DN600 / 24 INCH, QN=3200M3/H EN1092-1 PN25 CARBON STEEL. EN 1.0345 P235GH, PAINTED. IP68 SS HOUSING, PN40, O-RING, 50MM, 200DEG.C. CABLE GLANDS, M20 IN TRANSDUCERS AND M25 / M20 / M16 IN FUS060 TRANSMITTER. SITRANS FUS060 TRANSMITTER FOR REMOTE CONNECTION. SUPPLY: 115-230 V AC 50/60 HZ. HART, 4-20MA, ACTIVE OR PASSIVE PULSE, RELAY. TRANSDUCER CABLE: 4 3 METER, MAX. 70DEG.C"
SITRANS FUE950 CALCULATOR FOR ENERGY METERING. IP54 WALL MOUNT ENCLOSURE. SIEMENS FUE950 FLOW INPUT SETTING: PULSE VALUE 10 L/PULSE, MAX. FLOW RATE 3600 M3/H, (WITH OPTION L05: 10 GAL/P., MAX. FLOW RATE 60000 GPM). APPLICATION SETTING: FOR HEATING APPLICATIONS, FLOWMETER PLACED AT LOW TEMP. TEMPERATURE SENSOR TYPE: PT500 SENSOR PAIR (6/140 MM), 4-WIRE TYPE INCL. 5 M CABLE, 6 MM SENSOR DIAMETER AND 140 MM LENGTH, WITH MID &, PTB-K7.2 APPROVAL. TEMPERATURE SENSOR POCKETS: STAINLESS STEEL POCKETS FOR 6 MM SENSORS, 120/135 MM - G1/2 INCH, MAX. PN40 AND 5 M/S, (2 PCS). VOLTAGE SUPPLY: MAINS POWERED WITH 230 VAC MODULE (INCL. BACK-UP BATTERY). OPTION MODULES: ONE RS-485 MODULE (M-BUS). DISPLAY UNITS AND RESOLUTION: MWH, KW, M3, M3/H - 1 DIGIT RESOLUTION. APPROVAL / VERIFICATION: WITHOUT TYPE APPROVAL MARK, NEUTRAL LABEL (IN ENGLISH).
SITRANS FUE950 CALCULATOR FOR ENERGY METERING. IP54 WALL MOUNT ENCLOSURE. SIEMENS FUE950 FLOW INPUT SETTING: PULSE VALUE 10 L/PULSE, MAX. FLOW RATE 3600 M3/H, (WITH OPTION L05: 10 GAL/P., MAX. FLOW RATE 60000 GPM). APPLICATION SETTING: FOR HEATING APPLICATIONS, FLOWMETER PLACED AT LOW TEMP. TEMPERATURE SENSOR TYPE: PT500 SENSOR PAIR (6/140 MM), 4-WIRE TYPE INCL. 5 M CABLE, 6 MM SENSOR DIAMETER AND 140 MM LENGTH, WITH MID &, PTB-K7.2 APPROVAL. TEMPERATURE SENSOR POCKETS: STAINLESS STEEL POCKETS FOR 6 MM SENSORS, 120/135 MM - G1/2 INCH, MAX. PN40 AND 5 M/S, (2 PCS). VOLTAGE SUPPLY: MAINS POWERED WITH 230 VAC MODULE (INCL. BACK-UP BATTERY). OPTION MODULES: ONE PULSE OUTPUT MODULE (2 OUTPUTS, DEFAULT:ENERGY AND VOLUME, VALUE: LAST DISPLAY DIGIT). DISPLAY UNITS AND RESOLUTION: MWH, KW, M3, M3/H - 1 DIGIT RESOLUTION. APPROVAL / VERIFICATION: WITHOUT TYPE APPROVAL MARK, NEUTRAL LABEL (IN ENGLISH).
SITRANS FUE950 CALCULATOR FOR ENERGY METERING. IP54 WALL MOUNT ENCLOSURE. SIEMENS FUE950 FLOW INPUT SETTING: PULSE VALUE 100 L/PULSE, MAX. FLOW RATE 36000 M3/H (WITH OPTION L05: 100 GAL/P., MAX. FLOW RATE 600000 GPM). APPLICATION SETTING: FOR HEATING APPLICATIONS, FLOWMETER PLACED AT LOW TEMP. TEMPERATURE SENSOR TYPE: PT500 SENSOR PAIR (6/230 MM), 4-WIRE TYPE INCL. 5 M CABLE, 6 MM SENSOR DIAMETER AND 230 MM LENGTH, WITH MID &, PTB-K7.2 APPROVAL. TEMPERATURE SENSOR POCKETS: STAINLESS STEEL POCKETS FOR 6 MM SENSORS, 210/225 MM - G1/2 INCH, MAX. PN40 AND 5 M/S, (2 PCS). VOLTAGE SUPPLY: MAINS POWERED WITH 230 VAC MODULE (INCL. BACK-UP BATTERY). OPTION MODULES: M-BUS MODULE AND PULSE OUTPUT. MODULE (2 PULSE OUTPUTS). DISPLAY UNITS AND RESOLUTION: MWH, KW, M3, M3/H - 0 DIGIT RESOLUTION. APPROVAL / VERIFICATION: WITH MID TYPE APPROVAL MARK (ONLY FOR HEATING APPLICATION)

The Product is not Available now!

Check the Price with the manager.

STAND-ALONE THICKNESS GAUGE 7ME3951-0TG20 with 4 Hz, 5 MHz, -10 ... +50 °C

SONO 3200 COMPLETE TRANSDUCER, O-RING GASKET IN FFKM, LIQUID TEMPERATURE: -20 TO +200DEG.C, PN 40, LENGTH 50 MM, TERMINAL HOUSING IN SS, NPT CABLE GLAND.

FUS080 SPAREPART TRANSMITTER FOR FUS380 SYSTEMS (7ME340). TYPE SITRANS FUS080 IP67 POLYAMIDE, SUPPLY: 3.6V BATTERY. (THE ORIGINAL SYSTEM NUMBER AND SYSTEM SERIAL NUMBER MUST BE SPECIFIED ON ORDER).

FUS080 SPAREPART TRANSMITTER FOR FUS380 SYSTEMS (7ME340). TYPE SITRANS FUS080 IP67 POLYAMIDE, SUPPLY: 115-230V AC, 3.6V BU. (THE ORIGINAL SYSTEM NUMBER AND SYSTEM SERIAL NUMBER MUST BE SPECIFIED ON ORDER).
FUE080 SPAREPART TRANSMITTER FOR FUE380 SYSTEMS WITH CUSTODY TRANSFER APPROVAL (7ME341). TYPE SITRANS FUE080 IP67 POLYAMIDE, SUPPLY: 3.6V BATTERY. (THE ORIGINAL SYSTEM NUMBER AND SYSTEM SERIAL NUMBER MUST BE SPECIFIED ON ORDER. NOTE: A CUSTODY TRANSFER VERIFICATION IS NOT POSSIBLE).
FUS080 SPAREPART TRANSMITTER FOR SONOKIT SYS.7ME321&,322 TYPE SITRANS FUS080 IP67 POLYAMIDE SUPPLY: 3.6V, NO BATTERY (THE ORIGINAL SYSTEM NUMBER AND SYSTEM SERIAL NUMBER MUST BE SPECIFIED ON ORDER)

Siemens sitrans fus ultrasonic flowmeter photoSitrans F US is a range of ultrasonic flowmeters by Siemens for different purposes.

The company produces two versions of such sensors: inline and clamp-on. They differ in the type of mounting into the system. The Clamp-on version makes it easy to install the flowmeter externally on the pipeline. This allows don't cut the pipe for mounting and at any time to quickly reinstall the sensor to another area. Such feature also allows to work with sections of a very large diameter.

Siemens produces the following Clamp-on Sitrans F US series:

  • SITRANS FS 220
  • SITRANS FS 230

The system of such flowmeters consists of SITRANS FST 020 or SITRANS FST 030 transmitters that work with FSS200 measuring sensor.

In-line units are mounted directly into the pipeline. Such sensors can provide more accurate and reliable measurements.

The SITRANS F S inline family includes the following models:

  • SITRANS F US SONO 3100
  • SITRANS F US SONO 3300
  • SITRANS FUS380
  • SITRANS FUE380
  • SITRANS F US SONOKIT
  • SITRANS FUS880

SITRANS FUS060 and SITRANS FUS080 transmitters are available for use with these flowmeters type. The company also manufactures additional equipment, such as the Energy Calculator SITRANS FUE950, which may work even with electromagnetic sensors.

Siemens SItrans F S are modern ultrasonic flowmeters that are capable of working in pipes of any diameter, thanks to clamp-on versions or mounted directly in the pipeline for greater accuracy.

More detailed information you can see here: