DIAPHRAGM SEAL DIRECTLY MOUNTED TYPE 7MF4912, . PRESSURE EQUIPMENT DIRECTIVE F GAS 1/LIQUIDS 1 ART. 3.3 SEP DIRECTLY MOUNTED ON SITRANS P TRANSMITTER FOR LEVEL, DS SERIES, PROCESS CONNECTION ACC. EN 1092-1 / ASME B16.5 NOM. DIAMETER, NOM. PRESSURE: 3 INCH, CLASS 150 WETTED PARTS: STAINLESS STEEL, WITHOUT FOIL, EXTENSION 0 MM TRANSMISSION FLUID: SILICON OIL M5
COVER (DIE-CAST ALUMINIUM) WITH WINDOW INCL.O-RING FOR SERIES SITRANS P DSIII, DSIII PA AND DSIII FF

HART-MODEM WITH USB- INTERFACE

SITRANS P TRANSMITTER COMPACT FOR PRESSURE AND ABSOLUT PRESSURE FOR FOOD, PHARMACEU- TICALS AND BIOTECHNOLOGY, WITH DIAPHRAGM FLUSH AT FRONT. 2-WIRE SYSTEM, PROCESS TEMPERA- TURE UP TO 140 DEG. CEL., ACCURACY 0.2 % OF F.S.V. OUTPUT SIGNAL: 4...20 MA, PROCESS CONNECTION: QUICK-RELEASE CONNECTION: CLAMP CONNECTION ACCORDING ISO 2852: 1 INCH FILLING LIQUID: LIQUID FDA APPROVED OUTPUT SIGNAL : 4-20 MA HOUSING(STAINLESS STEEL1.4404)/ ELECTRICAL CONNECTION: FIELD HOUSING STAINLESS STEEL WITH CABLE GLAND, IP67 MEASURING RANGE: 0...1 BAR OVERLOAD PRESSURE: 10 BAR WITHOUT EXPLOSION PROTECTION
SITRANS P TRANSMITTER COMPACT FOR PRESSURE AND ABSOLUT PRESSURE FOR FOOD, PHARMACEU- TICALS AND BIOTECHNOLOGY, WITH DIAPHRAGM FLUSH AT FRONT. 2-WIRE SYSTEM, PROCESS TEMPERA- TURE UP TO 140 DEG. CEL., ACCURACY 0.2 % OF F.S.V. OUTPUT SIGNAL: 4...20 MA, PROCESS CONNECTION: QUICK-RELEASE CONNECTION: SMS-NORM WITH SCREW NECKS: 1 INCH FILLING LIQUID: LIQUID FDA APPROVED OUTPUT SIGNAL : 4-20 MA HOUSING(STAINLESS STEEL1.4404)/ ELECTRICAL CONNECTION: HOUSING WITH ANGELD PLUG ACCORDING DIN 43650, IP65 MEASURING RANGE: 0...1 BAR OVERLOAD PRESSURE: 10 BAR WITHOUT EXPLOSION PROTECTION

DOUBLE SHUT-OFF COCK DN 5 MAT. NO. 1.4404, MAX. OPERATING PRESSURE 420 BAR PRESSURE EQUIPMENT DIREKTIVE F. GAS 1/LIQUIDS 1 ART. 3.3 SEP

DOUBLE SHUT-OFF COCK DN 5 (SLEEVE - JOURNAL), MAT. NO. 1.4404, MAX. OPERATING PRESSURE 420 BAR PRESSURE EQUIPMENT DIREKTIVE F. GAS 1/LIQUIDS 1 ART. 3.3 SEP
DOUBLE SHUT-OFF COCK DN 5 (JOURNAL - JOURNAL), MAT. NO. 1.4404, MAX. OPERATING PRESSURE 420 BAR PRESSURE EQUIPMENT DIREKTIVE F. GAS 1/LIQUIDS 1 ART. 3.3 SEP
DOUBLE SHUT-OFF COCK DN 5 (SLEEVE - SLEEVE), MAT.NO. 1.4404, MAX. OPERATING PRESSURE 420 BAR PRESSURE EQUIPMENT DIREKTIVE FOR GAS 1/LIQUIDS 1 ART. 3.3 SEP
DOUBLE SHUT-OFF COCK DN 5 (COLLAR - SLEEVE), MAT. NO. 1.4404, MAX. OPERATING PRESSURE 420 BAR PRESSURE EQUIPMENT DIREKTIVE FOR GAS 1/LIQUIDS 1 ART. 3.3 SEP
DOUBLE SHUT-OFF VALVE DESIGN B, DIN 16272, WITH TEST AND CONNECTION COLLARS, MAX. OPERATING PRESSURE 400 BAR MAT. NO. 1.4571 PRESSURE EQUIPMENT DIREKTIVE F. GAS 1/LIQUIDS 1 ART. 3.3 SEP
DOUBLE SHUT-OFF VALVE DESIGN B, DIN 16272, WITH TEST COLLAR, PIPE UNION, MAT. NO. 1.4571, MAX. OPERATING PRESSURE 400 BAR PRESSURE EQUIPMENT DIREKTIVE F. GAS 1/LIQUIDS 1 ART. 3.3 SEP
3-SPINDLE VALVE MANIFOLD DN 5 FOR DIREKT FLANGING TO TRANSMITTERS, MAX. OPERATING PRESSURE 420 BAR PROCESS CONNECTION 1/2",-14 NPT- F. CONNECTION AT TRANSMITTER ACC. EN 61518 FORM B WITHOUT CERTIFICATE

Siemens SIWAREX electronic for SIMATIC ET200S-head station IM151-1 with BASIC/STANDARD/HIGH feature and IM151-7CPU.

Siemens 7MH5113-4LD00 rated load 3,5T, C3, 6 M cable length, 4 conductors,  protection class IP68

MOTION FAILURE ALARM MFA 4P: HIGHLY SENSITIVE SINGLE SET POINT MOTION SENSOR ALARM UNIT USED WITH MSP AND XPP PROBES ENCLOSURE: NEMA 4X, POLYCARBONATE ENCLOSURE INPUT VOLTAGE: 100/115/200/230 VAC, 50/60 HZ, SWITCH SELECTABLE. SPEED DETECTION VERSION: STANDARD, UNDERSPEED (U/S) OR OVERSPEED (O/S), SWITCH SELECTABLE APPROVALS: CE, CSA US/C, FM
REMOTE MOUNTED AMPLIFIER(RMA): REMOTE MOUNTED AMPLIFIER FOR MILLTRONICS MSP-1, MSP-3 AND MSP-9 MOTION SENSING PROBES . ENCLOSURE: ALUMINIUM ENCLOSURE, 1/2", NPT ENTRY
MOTION SENSING PROBES CE: A SERIES OF MOTION SENSING PROBES USED WITH THE MFA 4P CABLE LENGTH: STANDARD LENGTH (PER NOTES IN MODEL SECTION) MODEL: MSP-3, 1/2", NPT CONDUIT ENTRY WITH 1.5 M (5 FT) HIGH TEMPERATURE CABLE, ONLY WITH REMOTE MOUNTED AMPLIFIER (RMA) APPROVAL: CE
MOTION SENSING PROBES CE: A SERIES OF MOTION SENSING PROBES USED WITH THE MFA 4P CABLE LENGTH: STANDARD LENGTH (PER NOTES IN MODEL SECTION) MODEL: MSP-12, 1/2", NPT CABLE INLET APPROVAL: CE
SITRANS AS100: ACOUSTIC SENSOR FOR FLOW DETECTION. IT CAN WARN OF CHANGES TO MATERIAL FLOW TO PREVENT COSTLY DAMAGE OR DOWNTIME. SENSOR: STANDARD TEMPERATURE RANGE (-20 C TO +80 C) CABLE LENGTH: 4 METERS (13.12 FT) SENSOR MOUNTING: - . APPROVALS: CE
SITRANS CU 02: CONTROL UNIT ALARM CONTROL UNIT FOR USE WITH SITRANS AS 100 ACOUSTIC SENSOR. CONTAINS TWO FULLY PROGRAMMABLE, INDEPENDENT RELAYS FOR ALARM OR CONTROL, AS WELL AS 4-20MA OUTPUT. OPERATOR INTERFACE CONSISTS OF 4 PUSH BUTTON KEYS AND MULTI- FIELD LCD. INPUT VOLTAGE: 230 V AC ENCLOSURE: STANDARD DIN RAIL APPROVALS: CSA,CE
ECHOMAX XRS-5 TRANSDUCER WITH A BEAM ANGLE OF 10 DEG, THE XRS-5 PROVIDES RELIABLE, CONTINUOUS LEVEL MONITORING OF LIQUIDS AND SLURRIES IN NARROW LIFT STATIONS/WET WELLS, FLUMES, WEIRS AND FILTER BEDS. MEASURING RANGE: MIN. 0.3 M (1 FT), MAX. 8 M (26 FT) MOUNTING THREAD: 1", NPT (TAPER), ANSI/ASME B1.20.1 CABLE LENGTH: 5 M (16.40 FT) FACING: STANDARD (CSM RUBBER) APPROVALS: FM CLASS I ZONE 1, ATEX II 2G, CSA CLASS I DIV. 2, SAA EX S CLASS I ZONE 1 &, DIP PRACTICE A ZONE 20 BETRIEBSANLEITUNG: QUICK START, MEHRSPRACHIGE . FLANGE: WITHOUT MOUNTING FLANGE

ECHOMAX XRS-5 TRANSDUCER WITH A BEAM ANGLE OF 10 DEG, THE XRS-5 PROVIDES RELIABLE, CONTINUOUS LEVEL MONITORING OF LIQUIDS AND SLURRIES IN NARROW LIFT STATIONS/WET WELLS, FLUMES, WEIRS AND FILTER BEDS. MEASURING RANGE: MIN. 0.3 M (1 FT), MAX. 8 M (26 FT) MOUNTING THREAD: 1&quot, NPT (TAPER), ANSI/ASME B1.20.1 CABLE LENGTH: 30 M (98.43 FT) FACING: STANDARD (CSM RUBBER) APPROVALS: FM CLASS I ZONE 1, ATEX II 2G, CSA CLASS I DIV. 2, SAA EX S CLASS I ZONE 1 &amp, DIP PRACTICE A ZONE 20 BETRIEBSANLEITUNG: QUICK START, MEHRSPRACHIGE . FLANGE: WITHOUT MOUNTING FLANGE

ECHOMAX XRS-5 TRANSDUCER WITH A BEAM ANGLE OF 10 DEG, THE XRS-5 PROVIDES RELIABLE, CONTINUOUS LEVEL MONITORING OF LIQUIDS AND SLURRIES IN NARROW LIFT STATIONS/WET WELLS, FLUMES, WEIRS AND FILTER BEDS. MEASURING RANGE: MIN. 0.3 M (1 FT), MAX. 8 M (26 FT) MOUNTING THREAD: R 1", ((BSPT), EN 10226) CABLE LENGTH: 5 M (16.40 FT) FACING: STANDARD (CSM RUBBER) APPROVALS: FM CLASS I ZONE 1, ATEX II 2G, CSA CLASS I DIV. 2, SAA EX S CLASS I ZONE 1 &, DIP PRACTICE A ZONE 20 BETRIEBSANLEITUNG: QUICK START, MEHRSPRACHIGE . FLANGE: . DN 100 STYLE, PN 10/16, TYPE A, FLAT FACED
ECHOMAX XRS-5 TRANSDUCER WITH A BEAM ANGLE OF 10 DEG, THE XRS-5 PROVIDES RELIABLE, CONTINUOUS LEVEL MONITORING OF LIQUIDS AND SLURRIES IN NARROW LIFT STATIONS/WET WELLS, FLUMES, WEIRS AND FILTER BEDS. MEASURING RANGE: MIN. 0.3 M (1 FT), MAX. 8 M (26 FT) MOUNTING THREAD: R 1", ((BSPT), EN 10226) CABLE LENGTH: 10 M (32.81 FT) FACING: STANDARD (CSM RUBBER) APPROVALS: FM CLASS I ZONE 1, ATEX II 2G, CSA CLASS I DIV. 2, SAA EX S CLASS I ZONE 1 &, DIP PRACTICE A ZONE 20 BETRIEBSANLEITUNG: QUICK START, MEHRSPRACHIGE . FLANGE: WITHOUT MOUNTING FLANGE
ECHOMAX XPS-10 TRANSDUCER HIGH-FREQUENCY ULTRASONIC TRANSDUCER DESIGNED FOR A WIDE VARIETY OF LIQUID AND SOLID APPLICATIONS, FOR USE WITH APPROVED CONTROLLERS. INCLUDES INTEGRAL TEMPERATURE SENSOR. MEASURING RANGE: MIN. 0.3M, MAX. 10M MOUNTING THREAD AND FACING: 1", NPT ((TAPER), ANSI/ASME B1.20.1) CABLE LENGTH: 5 M (16.40 FT) FLANGE, FLUSH MOUNT: NO FLANGE APPROVALS: ATEX II 2GD,FM CLASS I DIV 2/SAA CLASS 1 ZONE 1 .
ECHOMAX XPS-10 TRANSDUCER HIGH-FREQUENCY ULTRASONIC TRANSDUCER DESIGNED FOR A WIDE VARIETY OF LIQUID AND SOLID APPLICATIONS, FOR USE WITH APPROVED CONTROLLERS. INCLUDES INTEGRAL TEMPERATURE SENSOR. MEASURING RANGE: MIN. 0.3M, MAX. 10M MOUNTING THREAD AND FACING: 1", NPT ((TAPER), ANSI/ASME B1.20.1), FOAM FACING CABLE LENGTH: 5 M (16.40 FT) FLANGE, FLUSH MOUNT: NO FLANGE APPROVALS: ATEX II 2GD,FM CLASS I DIV 2/SAA CLASS 1 ZONE 1 .
ECHOMAX XPS-10 TRANSDUCER HIGH-FREQUENCY ULTRASONIC TRANSDUCER DESIGNED FOR A WIDE VARIETY OF LIQUID AND SOLID APPLICATIONS, FOR USE WITH APPROVED CONTROLLERS. INCLUDES INTEGRAL TEMPERATURE SENSOR. MEASURING RANGE: MIN. 0.3M, MAX. 10M MOUNTING THREAD AND FACING: R 1", ((BSPT) EN 10226-1) CABLE LENGTH: 10 M (32.81 FT) FLANGE, FLUSH MOUNT: NO FLANGE APPROVALS: ATEX II 2GD,FM CLASS I DIV 2/SAA CLASS 1 ZONE 1 .
ECHOMAX XPS-15 TRANSDUCER HIGH-FREQUENCY ULTRASONIC TRANSDUCER DESIGNED FOR A WIDE VARIETY OF LIQUID AND SOLID APPLICATIONS, FOR USE WITH APPROVED CONTROLLERS. INCLUDES INTEGRAL TEMPERATURE SENSOR. MEASURING RANGE: MIN. 0.3M, MAX. 15 M MOUNTING THREAD AND FACING: 1", NPT ((TAPER), ANSI/ASME B1.20.1) CABLE LENGTH: 5 M (16.40 FT) FLANGE: NO MOUNTING FLANGE APPROVALS: ATEX II 2GD, FM CLASS I DIV 2/SAA CLASS 1 ZONE 1 MANUAL: MULTI-LANGUAGE,QUICK START

ECHOMAX XPS-15 TRANSDUCER HIGH-FREQUENCY ULTRASONIC TRANSDUCER DESIGNED FOR A WIDE VARIETY OF LIQUID AND SOLID APPLICATIONS, FOR USE WITH APPROVED CONTROLLERS. INCLUDES INTEGRAL TEMPERATURE SENSOR. MEASURING RANGE: MIN. 0.3M, MAX. 15 M MOUNTING THREAD AND FACING: 1&quot, NPT ((TAPER), ANSI/ASME B1.20.1) CABLE LENGTH: 10 M (32.81 FT) FLANGE: NO MOUNTING FLANGE APPROVALS: ATEX II 2GD, FM CLASS I DIV 2/SAA CLASS 1 ZONE 1 MANUAL: MULTI-LANGUAGE,QUICK START