Endress+Hauser Proline Promag 10E
Electromagnetic flowmeter
Max. measurement error
Volume flow: В±0.5 % o.r. В± 1 mm/s (0.04 in/s)
Measuring range
4 dmВі/min to 9600 mВі/h (1 to 44 000 gal/min)
Medium temperature range
10 to +110 В°C (+14 to +230 В°F)
Max. process pressure
PN 40, Class 150, 20K
Wetted materials
Liner: PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
- Overview
- Comments
The economical flowmeter with a highly cost-effective transmitter.
Measuring principle
Electromagnetic
Product headline
The economical flowmeter with a highly cost-effective transmitter.
Fully suitable for basic applications in the chemical and process industry.
Sensor features
Cost-effective sensor ideal solution for basic requirements. Energy...saving flow measurement no pressure loss due to cross section constriction. Maintenance...free no moving parts.
Nominal diameter: max. DN 600 (24"). All common process connections. Liner made of PTFE.
Transmitter features
Cost-effective designed for easy applications and direct integration. Safe operation display provides easily readable process information. Fully industry-compliant IEC/EN/NAMUR.
2-line display with push buttons. Device as compact or remote version. HART.
Nominal diameter range
DN 15 to 600 (ВЅ to 24")
Wetted materials
Liner: PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
Measured variables
Volume flow
Max. measurement error
Volume flow: В±0.5 % o.r. В± 1 mm/s (0.04 in/s)
Measuring range
4 dmВі/min to 9600 mВі/h (1 to 44 000 gal/min)
Max. process pressure
PN 40, Class 150, 20K
Medium temperature range
10 to +110 В°C (+14 to +230 В°F)
Ambient temperature range
10 to +60 В°C (+14 to +140 В°F)
Sensor housing material
DN 15 to 300 (ВЅ to 12"): AlSi10Mg, coated
DN 350 to 600 (14 to 24"): Carbon steel with protective varnish
Sensor connection housing: AlSi10Mg, coated
Transmitter housing material
Powder...coated die...cast aluminum
Degree of protection
Compact version: IP67, type 4X enclosure
Sensor remote version (standard): IP67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure
Transmitter remote version: IP67, type 4X enclosure
Display/Operation
2...line display with push buttons
Configuration via local display and operating tools possible
Outputs
4...20 mA HART (active)
Pulse/switch output (passive)
Inputs
None
Digital communication
HART
Power supply
DC 11 to 40 V
AC 85 to 250 V (45 to 65 Hz)
AC 20 to 28 V (45 to 65 Hz)
Hazardous area approvals
cCSAus
Product safety
CE, C-tick, EAC marking
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Pressure approvals and certificates
PED
Comments
No comments yet