Endress+Hauser Proline Promag 10E
Electromagnetic flowmeter

Endress+Hauser Proline Promag 10E

Max. measurement error

Volume flow: В±0.5 % o.r. В± 1 mm/s (0.04 in/s)

Measuring range

4 dmВі/min to 9600 mВі/h (1 to 44 000 gal/min)

Medium temperature range

10 to +110 В°C (+14 to +230 В°F)

Max. process pressure

PN 40, Class 150, 20K

Wetted materials

Liner: PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)

Item Number: Proline Promag 10E
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

The economical flowmeter with a highly cost-effective transmitter.

Measuring principle

Electromagnetic

Product headline

The economical flowmeter with a highly cost-effective transmitter.
Fully suitable for basic applications in the chemical and process industry.

Sensor features

Cost-effective sensor ideal solution for basic requirements. Energy...saving flow measurement no pressure loss due to cross section constriction. Maintenance...free no moving parts.
Nominal diameter: max. DN 600 (24"). All common process connections. Liner made of PTFE.

Transmitter features

Cost-effective designed for easy applications and direct integration. Safe operation display provides easily readable process information. Fully industry-compliant IEC/EN/NAMUR.
2-line display with push buttons. Device as compact or remote version. HART.

Nominal diameter range

DN 15 to 600 (ВЅ to 24")

Wetted materials

Liner: PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)

Measured variables

Volume flow

Max. measurement error

Volume flow: В±0.5 % o.r. В± 1 mm/s (0.04 in/s)

Measuring range

4 dmВі/min to 9600 mВі/h (1 to 44 000 gal/min)

Max. process pressure

PN 40, Class 150, 20K

Medium temperature range

10 to +110 В°C (+14 to +230 В°F)

Ambient temperature range

10 to +60 В°C (+14 to +140 В°F)

Sensor housing material

DN 15 to 300 (ВЅ to 12"): AlSi10Mg, coated
DN 350 to 600 (14 to 24"): Carbon steel with protective varnish
Sensor connection housing: AlSi10Mg, coated

Transmitter housing material

Powder...coated die...cast aluminum

Degree of protection

Compact version: IP67, type 4X enclosure
Sensor remote version (standard): IP67, type 4X enclosure
Sensor remote version (option): IP68, type 6P enclosure
Transmitter remote version: IP67, type 4X enclosure

Display/Operation

2...line display with push buttons
Configuration via local display and operating tools possible

Outputs

4...20 mA HART (active)
Pulse/switch output (passive)

Inputs

None

Digital communication

HART

Power supply

DC 11 to 40 V
AC 85 to 250 V (45 to 65 Hz)
AC 20 to 28 V (45 to 65 Hz)

Hazardous area approvals

cCSAus

Product safety

CE, C-tick, EAC marking

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

Pressure approvals and certificates

PED

Comments

No comments yet

Write a comment