Pepperl+Fuchs NJ0,8-5GM-N-Y287110 Inductive sensor

Pepperl+Fuchs NJ0,8-5GM-N-Y287110
Item Number: NJ0,8-5GM-N-Y287110
  • 0.8 mm flush
  • Usable up to SIL 2 acc. to IEC 61508
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments
Sensing facePBT
StandardsIEC 61241-11:2002: draft; prEN61241-0:2002
type of protection intrinsic safety ""iD""
Use is restricted to the following stated conditions
ATEX marking II 1G Ex ia IIC T6andhellip;T1 Ga
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
CE marking[*PD-Z02585A*]
Effective internal capacitancemax. 30 nF ; a cable length of 10 m is considered.
Degree of protectionIP67
Switching frequency0 ... 5000 Hz
Connection typecable PVC , 0.085 m
Operating voltage5 ... 25 V
Output typeNAMUR
Appropriate typeNJ 0,8-5GM-N...
Effective internal inductancemax. 50 andmicro;H ; a cable length of 10 m is considered.
Effective internal capacitancemax. 30 nF ; a cable length of 10 m is considered.
Ambient temperature-25 ... 100 В°C (-13 ... 212 В°F)
Reduction factor rAl 0.4
Mission Time (TM)20 a
Effective internal inductancemax. 50 andmicro;H ; a cable length of 10 m is considered.
Switching functionNormally closed (NC)
Hysteresis3 %
Nominal voltage8.2 V (Ri approx. 1 kandOmega;)
CE marking[*PD-Z02585A*]
MTTFd1050 a
Housing materialStainless steel 1.4305 / AISI 303
Effective internal inductancemax. 50 andmicro;H ; a cable length of 10 m is considered.
Core cross-section0.14 mm2
StandardsEN 60079-0:2012, EN 60079-11:2012
Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
ATEX marking II 1D Ex iaD 20 T 108 В°C (226.4 В°F)
The Ex-relevant identification may also be printed on the accompanying adhesive label.
Assured operating distance0 ... 0.65 mm
Ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1:2007 has already been accounted for in the temperature table for category 1.
ATEX marking II 1G Ex ia IIC T6andhellip;T1 Ga
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Installationflush
CE marking[*PD-Z02585A*]
Appropriate typeNJ 0,8-5GM-N...
Output type2-wire
Reduction factor r304 0.85
Diagnostic Coverage (DC)0 %
StandardsEN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007
Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Effective internal capacitancemax. 30 nF ; a cable length of 10 m is considered.
Appropriate typeNJ0,8-5GM-N...
CCC approvalCCC approval / marking not required for products rated 36 V
Rated operating distance0.8 mm
Use in the hazardous areasee instruction manuals
Reduction factor rCu 0.3

Comments

No comments yet

Write a comment

in international format without spaces
All fields are required