Pepperl+Fuchs OBT350-R100-E5-IO-V31

Triangulation sensor (BGS)
Pepperl+Fuchs OBT350-R100-E5-IO-V31
Price on Request
One click request
Process data widthProcess data input 1 Bit
Process data output 2 Bit
Adjustment range25 ... 350 mm
Switching typeThe switching type of the sensor is adjustable. The default setting is:
C/Q - BK: PNP normally open / light-on, IO-Link
Reference targetstandard white, 100 mm x 100 mm
Ambient temperature-40 ... 60 В°C (-40 ... 140 В°F)
SIO mode supportyes
No-load supply current< 25 mA at 24 V supply voltage
Black/White difference (6 %/90 %)< 15 % at 350 mm
Voltage drop≤ 1.5 V DC
Housing height44.5 mm
Usage categoryDC-12 and DC-13
Control elementsLight-on/dark-on changeover switch
LED risk group labellingexempt group
Interface typeIO-Link ( via C/Q = pin 4 )
Function indicatorLED yellow:
constantly on - object detected
constantly off - object not detected
Mission Time (TM)20 a
ConnectionM8 x 1 connector, 4-pin
Ripplemax. 10 %
Light typemodulated visible red light
Product standardEN 60947-5-2
Control elementsSensing range adjuster
Device ID0x110613 (1115667)
Diagnostic Coverage (DC)0 %
Ambient light limitEN 60947-5-2 : 40000 Lux
MTTFd600 a
Housing width11 mm
UL approvalE87056 , cULus Listed , class 2 power supply , type rating 1
Compatible master port typeA
Angle of divergenceapprox. 3 В°
Device profileSmart Sensor
Protection classIII
Degree of protectionIP67 / IP69 / IP69K
Min. cycle time2.3 ms
Switching voltagemax. 30 V DC
IO-Link Revision1.1
Detection range min.5 ... 25 mm
Switching frequency500 Hz
Detection range5 ... 350 mm
Light sourceLED
Housing depth21.5 mm
Response time1 ms
Detection range max.5 ... 350 mm
Massapprox. 10 g
Operation indicatorLED green:
constantly on - power on
flashing (4Hz) - short circuit
flashing with short break (1 Hz) - IO-Link mode
Switching currentmax. 100 mA , resistive load
Transfer rateCOM 2 (38.4 kBaud)
Storage temperature-40 ... 70 В°C (-40 ... 158 В°F)
Operating voltage10 ... 30 V DC
Diameter of the light spotapprox. 20 mm at a distance of 350 mm
Communication interfaceIEC 61131-9
Signal output1 PNP, short-circuit protected, reverse polarity protected
in international format without spaces
All fields are required