Pepperl+Fuchs OMT300-R200-EP-IO-V3-L

Distance sensor
Pepperl+Fuchs OMT300-R200-EP-IO-V3-L
Price on Request
One click request
Resolution0.1 mm
Function indicatorLED yellow:
constantly on - switch output active
constantly off - switch output inactive
Angle of divergenceapprox. 0.3 В°
Repeat accuracy< 0.5 %
Switching currentmax. 100 mA , resistive load
Switching voltagemax. 30 V DC
Degree of protectionIP67 / IP69 / IP69K
Device profileIdentification and diagnosis
Smart Sensor type 0/type 3.3
Ambient temperature10 ... 60 В°C (50 ... 140 В°F)
Angle deviationmax. +/- 1.5 В°
Linearity error0.5 %
ConnectionConnector plug, M8 x 1, 3 pin, rotatable by 90В°
Diagnostic Coverage (DC)0 %
UL approvalE87056 , cULus Listed , class 2 power supply , type rating 1
Operation indicatorLED green:
constantly on - power on
flashing (4Hz) - short circuit
flashing with short break (1 Hz) - IO-Link mode
Laser safetyEN 60825-1:2014
Compatible master port typeA
Signal output1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected, overvoltage protected
Reference targetstandard white, 100 mm x 100 mm
Mission Time (TM)20 a
Warm up time5 min
Interface typeIO-Link ( via C/Q = pin 4 )
Protection classIII
Device ID0x11190A (1120522)
Switching typeThe default setting is:
C/Q - Pin4: NPN normally open, PNP normally closed, IO-Link
Measurement range100 ... 300 mm
Product standardEN 60947-5-2
Temperature drift0.05 %/K
Storage temperature-40 ... 70 В°C (-40 ... 158 В°F)
Housing depth41.7 mm
IO-Link Revision1.1
MTTFd560 a
Usage categoryDC-12 and DC-13
Massapprox. 35 g
Voltage drop≤ 1.5 V DC
No-load supply current< 16 mA at 24 V supply voltage
FDA approvalIEC 60825-1:2014 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007
Communication interfaceIEC 61131-9
Ripplemax. 10 %
Process data widthProcess data input 4 byte
Process data output 2 bits
Ambient light limitEN 60947-5-2 : 45000 Lux
Response time2 ms
Transfer rateCOM 2 (38.4 kBaud)
Min. cycle time3 ms
Operating voltage10 ... 30 V DC
Control elementsTeach-In key
Light typemodulated visible red light
Light sourcelaser diode
Housing height50.6 mm
Housing width15 mm
SIO mode supportyes
Control elements5-step rotary switch for operating modes selection
CCC approvalCCC approval / marking not required for products rated ≤36 V
Diameter of the light spotapprox. 3 mm at a distance of 300 mm
in international format without spaces