Pepperl+Fuchs OMT300-R201-2EP-IO-L

Distance sensor
Pepperl+Fuchs OMT300-R201-2EP-IO-L
Price on Request
One click request
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ripplemax. 10 %
Diameter of the light spotapprox. 3 mm at a distance of 300 mm
Storage temperature-40 ... 70 В°C (-40 ... 158 В°F)
Product standardEN 60947-5-2
Compatible master port typeA
Response time2 ms
Interface typeIO-Link ( via C/Q = BK )
Connection2 m fixed cable
Housing depth41.7 mm
Repeat accuracy< 0.5 %
Measurement range100 ... 300 mm
Min. cycle time3 ms
FDA approvalIEC 60825-1:2014 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007
Reference targetstandard white, 100 mm x 100 mm
Housing width15 mm
Process data widthProcess data input 4 byte
Process data output 2 bits
Laser safetyEN 60825-1:2014
Warm up time5 min
Usage categoryDC-12 and DC-13
Light sourcelaser diode
Cable length2 m
SIO mode supportyes
Control elements5-step rotary switch for operating modes selection
Degree of protectionIP67 / IP69 / IP69K
Temperature drift0.05 %/K
Function indicatorLED yellow:
constantly on - switch output active
constantly off - switch output inactive
Control elementsTeach-In key
Device ID0x11191A (1120538)
Angle deviationmax. +/- 1.5 В°
Voltage drop≤ 1.5 V DC
Ambient temperature10 ... 60 В°C (50 ... 140 В°F)
Operating voltage10 ... 30 V DC
Housing height61.7 mm
Light typemodulated visible red light
IO-Link Revision1.1
Mission Time (TM)20 a
UL approvalE87056 , cULus Listed , class 2 power supply , type rating 1
Resolution0.1 mm
Switching voltagemax. 30 V DC
Operation indicatorLED green:
constantly on - power on
flashing (4Hz) - short circuit
flashing with short break (1 Hz) - IO-Link mode
MTTFd560 a
No-load supply current< 16 mA at 24 V supply voltage
Signal output2 push-pull (4 in 1)outputs, short-circuit protected, reverse polarity protected, overvoltage protected
Device profileIdentification and diagnosis
Smart Sensor type 0/type 3.3
Transfer rateCOM 2 (38.4 kBaud)
Switching typeThe default setting is:
C/Q - BK: NPN normally open, PNP normally closed, IO-Link
Q2 - WH: NPN normally open, PNP normally closed
Massapprox. 73 g
Diagnostic Coverage (DC)0 %
Linearity error0.5 %
Angle of divergenceapprox. 0.3 В°
Ambient light limitEN 60947-5-2 : 45000 Lux
Switching currentmax. 100 mA , resistive load
Communication interfaceIEC 61131-9
Protection classIII
in international format without spaces