Pepperl+Fuchs OMT600-R200-IEP-IO-V31-L

Distance sensor
Pepperl+Fuchs OMT600-R200-IEP-IO-V31-L
Price on Request
One click request
Massapprox. 35 g
Angle deviationmax. +/- 1.5 В°
Output type1 current output: 4 ... 20 mA
Diameter of the light spotapprox. 3 mm at a distance of 600 mm
Signal output1 push-pull output , 1 analog output , short-circuit-proof, reverse polarity protection, surge-proof
Storage temperature-40 ... 70 В°C (-40 ... 158 В°F)
Warm up time5 min
Compatible master port typeA
Ambient light limitEN 60947-5-2 : 15000 Lux
Response time2 ms
Linearity error0.75 %
Light sourcelaser diode
MTTFd470 a
Ambient temperature10 ... 50 В°C (50 ... 122 В°F)
Min. cycle time3 ms
Degree of protectionIP67 / IP69 / IP69K
CCC approvalCCC approval / marking not required for products rated ≤36 V
Interface typeIO-Link ( via C/Q = pin 4 )
Control elements5-step rotary switch for operating modes selection
Function indicatorLED yellow:
constantly on - switch output active
constantly off - switch output inactive
IO-Link Revision1.1
Device ID0x111908 (1120520)
Voltage drop≤ 1.5 V DC
Housing depth41.7 mm
Reference targetstandard white, 100 mm x 100 mm
Usage categoryDC-12 and DC-13
Mission Time (TM)20 a
Protection classIII
FDA approvalIEC 60825-1:2014 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007
ConnectionM8 x 1 connector, 4-pin
Communication interfaceIEC 61131-9
Switching typeThe default setting is:
C/Q - Pin4: NPN normally open, PNP normally closed, IO-Link
I—Pin2: analog output 4...20 mA
Control elementsTeach-In key
Temperature drift0.05 %/K
Transfer rateCOM 2 (38.4 kBaud)
Operation indicatorLED green:
constantly on - power on
flashing (4Hz) - short circuit
flashing with short break (1 Hz) - IO-Link mode
Resolution0.1 mm
UL approvalE87056 , cULus Listed , class 2 power supply , type rating 1
Load resistor> 1 kΩ voltage output ; ≤ 470 Ω current output
Housing width15 mm
Switching voltagemax. 30 V DC
Housing height50.6 mm
Switching currentmax. 100 mA , resistive load
No-load supply current< 18 mA at 24 V supply voltage
Operating voltage18 ... 30 V DC
Product standardEN 60947-5-2
Diagnostic Coverage (DC)0 %
Measurement range100 ... 600 mm
Process data widthProcess data input 4 byte
Process data output 2 bits
Ripplemax. 10 %
Laser safetyEN 60825-1:2014
Device profileIdentification and diagnosis
Smart Sensor type 0/type 3.3
Light typemodulated visible red light
Angle of divergenceapprox. 0.3 В°
SIO mode supportyes
Repeat accuracy< 1 %
in international format without spaces