Pepperl+Fuchs OMT600-R201-2EP-IO-0,3M-V31-L

Distance sensor
Pepperl+Fuchs OMT600-R201-2EP-IO-0,3M-V31-L
Price on Request
One click request
Resolution0.1 mm
Signal output2 push-pull (4 in 1)outputs, short-circuit protected, reverse polarity protected, overvoltage protected
Product standardEN 60947-5-2
Degree of protectionIP67 / IP69 / IP69K
Usage categoryDC-12 and DC-13
CCC approvalCCC approval / marking not required for products rated ≤36 V
Measurement range100 ... 600 mm
Switching voltagemax. 30 V DC
No-load supply current< 16 mA at 24 V supply voltage
Diameter of the light spotapprox. 3 mm at a distance of 600 mm
Massapprox. 51 g
Control elements5-step rotary switch for operating modes selection
Ripplemax. 10 %
Diagnostic Coverage (DC)0 %
Compatible master port typeA
Protection classIII
Repeat accuracy< 1 %
Process data widthProcess data input 4 byte
Process data output 2 bits
Min. cycle time3 ms
Light typemodulated visible red light
Cable length0.3 m
Temperature drift0.05 %/K
Voltage drop≤ 1.5 V DC
Interface typeIO-Link ( via C/Q = pin 4 )
Housing height61.7 mm
Transfer rateCOM 2 (38.4 kBaud)
Response time2 ms
Switching currentmax. 100 mA , resistive load
Linearity error0.75 %
Communication interfaceIEC 61131-9
Mission Time (TM)20 a
Housing width15 mm
IO-Link Revision1.1
MTTFd560 a
Device profileIdentification and diagnosis
Smart Sensor type 0/type 3.3
UL approvalE87056 , cULus Listed , class 2 power supply , type rating 1
FDA approvalIEC 60825-1:2014 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007
Control elementsTeach-In key
SIO mode supportyes
Storage temperature-40 ... 70 В°C (-40 ... 158 В°F)
Ambient light limitEN 60947-5-2 : 15000 Lux
Angle deviationmax. +/- 1.5 В°
Angle of divergenceapprox. 0.3 В°
Device ID0x111917 (1120535)
Function indicatorLED yellow:
constantly on - switch output active
constantly off - switch output inactive
Housing depth41.7 mm
Ambient temperature10 ... 60 В°C (50 ... 140 В°F)
Connectionfixed cable 300 mm with M8 x 1 male connector; 4-pin
Operating voltage10 ... 30 V DC
Switching typeThe default setting is:
C/Q - Pin4: NPN normally open, PNP normally closed, IO-Link
Q2 - Pin2: NPN normally open, PNP normally closed
Warm up time5 min
Light sourcelaser diode
Operation indicatorLED green:
constantly on - power on
flashing (4Hz) - short circuit
flashing with short break (1 Hz) - IO-Link mode
Laser safetyEN 60825-1:2014
Reference targetstandard white, 100 mm x 100 mm