Pepperl+Fuchs OQT350-R201-2EP-IO-V1-L

Triangulation sensor (SbR)
Pepperl+Fuchs OQT350-R201-2EP-IO-V1-L
Price on Request
One click request
Switching typeThe default setting is:
C/Q - Pin4: NPN normally open, PNP normally closed, IO-Link
Q2 - Pin2: NPN normally open, PNP normally closed
Switching voltagemax. 30 V DC
Angle of divergenceapprox. 0.3 В°
Protection classIII
No-load supply current< 16 mA at 24 V supply voltage
Voltage drop≤ 1.5 V DC
Product standardEN 60947-5-2
SIO mode supportyes
MTTFd560 a
Ambient temperature-40 ... 60 В°C (-40 ... 140 В°F)
Switching currentmax. 100 mA , resistive load
Detection range60 ... 350 mm
Device ID0x111812 (1120274)
Diameter of the light spotapprox. 3 mm at a distance of 350 mm
Usage categoryDC-12 and DC-13
Switching frequency217 Hz
Operating voltage10 ... 30 V DC
Signal output2 push-pull (4 in 1)outputs, short-circuit protected, reverse polarity protected, overvoltage protected
Transfer rateCOM 2 (38.4 kBaud)
Massapprox. 47 g
Min. cycle time2.3 ms
Laser safetyEN 60825-1:2014
FDA approvalIEC 60825-1:2014 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007
Light sourcelaser diode
Device profileIdentification and diagnosis
Smart Sensor type 0
Response time2.3 ms
Compatible master port typeA
Storage temperature-40 ... 70 В°C (-40 ... 158 В°F)
Communication interfaceIEC 61131-9
UL approvalE87056 , cULus Listed , class 2 power supply , type rating 1
Black/White difference (6 %/90 %)< 2 %
Operation indicatorLED green:
constantly on - power on
flashing (4Hz) - short circuit
flashing with short break (1 Hz) - IO-Link mode
Mission Time (TM)20 a
Interface typeIO-Link ( via C/Q = pin 4 )
Control elementsTeach-In key
Control elements5-step rotary switch for operating modes selection
IO-Link Revision1.1
Connection4-pin, M12 x 1 connector, 90В° rotatable
Function indicatorLED yellow:
constantly on - switch output active
constantly off - switch output inactive
Housing depth41.7 mm
Housing height61.7 mm
Ripplemax. 10 %
Detection range max.40 ... 400 mm
CCC approvalCCC approval / marking not required for products rated ≤36 V
Housing width15 mm
Diagnostic Coverage (DC)0 %
Light typemodulated visible red light
Degree of protectionIP67 / IP69 / IP69K
Adjustment range100 ... 350 mm
Ambient light limitEN 60947-5-2 : 45000 Lux
Reference targetstandard white, 100 mm x 100 mm
Detection range min.60 ... 100 mm
Process data widthProcess data input 2 Bit
Process data output 2 Bit
in international format without spaces