- Sensing range 150...1600 mm
- Operating voltage 10...30 DC
- ("supply class 2" to cULus) V
- NPN
- M12 Connector
- Sensing range 150...1600 mm
- Operating voltage 10...30 DC
- ("supply class 2" to cULus) V
- NPN
- M12 Connector
- Sensing range 150...1600 mm
- Operating voltage 10...30 DC
- ("supply class 2" to cULus) V
- NPN
- M12 Connector
- Sensing range 200...2200 mm
- Operating voltage 10...30 DC
- ("supply class 2" to cULus) V
- NPN
- M12 Connector
- Sensing range 200...2200 mm
- Operating voltage 10...30 DC
- ("supply class 2" to cULus) V
- NPN
- M12 Connector
- Sensing range 200...2200 mm
- Operating voltage 10...30 DC
- ("supply class 2" to cULus) V
- NPN
- M12 Connector
- Sensing range 60...800 mm
- Operating voltage 10...30 DC
- ("supply class 2" to cULus) V
- PNP
- M12 Connector
- Sensing range 40...300 mm
- Operating voltage 10...30 DC
- ("supply class 2" to cULus) V
- PNP
- M12 Connector
- Reliable measurement independent of material color, transparency, gloss and ambient light
- Four ranges up to 1,300 mm
- Short plastic M18 housing with a length of 41 mm
- Integrated time-of-flight technology detects objects such as glass, liquids and transparent foils, independent of color
- Range up to 8,000 mm
- Display enables fast and flexible sensor adjustment
- Integrated time-of-flight technology detects objects such as glass, liquids and transparent foils, independent of color
- Range up to 8,000 mm
- Display enables fast and flexible sensor adjustment
art. 10140060
| scanning range sd | 10 ... 200 mm |
| scanning range far limit Sde | 30 ... 200 mm |
| hysteresis typ. | 4 % Sde |
| output circuit | PNP make function (NO) |
| operating temperature | -10 ... +60 °C |
art. 10149127 Baumer ultrasonic sensors
| scanning range sd | 100 ... 1000 mm |
| scanning range close limit Sdc | 100 ... 1000 mm |
| scanning range far limit Sde | 100 ... 1000 mm |
| output circuit | voltage output |
| operating temperature | -10 ... +60 °C |
art. 10134142
| scanning range sd | 400 ... 2500 mm |
| scanning range close limit Sdc | 400 ... 2500 mm |
| scanning range far limit Sde | 400 ... 2500 mm |
| output circuit | current output |
| operating temperature | -10 ... +60 °C |
art. 10129530
| scanning range sd | 400 ... 2500 mm |
| scanning range close limit Sdc | 400 ... 2500 mm |
| scanning range far limit Sde | 400 ... 2500 mm |
| output circuit | current output |
| operating temperature | -10 ... +60 °C |
art. 10130405
| scanning range sd | 350 ... 2500 mm |
| scanning range far limit Sde | 350 ... 2500 mm |
| hysteresis typ. | 4 % Sde |
| output circuit | NPN make function (NO) |
| operating temperature | -25 ... +60 °C |
art. 10156679
| scanning range sd | 400 ... 2500 mm |
| scanning range close limit Sdc | 400 ... 2500 mm |
| scanning range far limit Sde | 400 ... 2500 mm |
| output circuit | voltage output |
| operating temperature | -10 ... +60 °C |
art. 10131880
| scanning range sd | 400 ... 2500 mm |
| scanning range close limit Sdc | 400 ... 2500 mm |
| scanning range far limit Sde | 400 ... 2500 mm |
| output circuit | voltage output |
| operating temperature | -10 ... +60 °C |
art. 10162125
| special type | chemically resistant |
| scanning range sd | 60 ... 400 mm |
| scanning range close limit Sdc | 60 ... 400 mm |
| output circuit | current output |
| operating temperature | 0 ... +60 °C |
art. 10161023
| special type | chemically resistant |
| scanning range sd | 100 ... 1000 mm |
| scanning range far limit Sde | 100 ... 1000 mm |
| output circuit | NPN make function (NO) |
| operating temperature | 0 ... +60 °C |
art. 10161024
| special type | chemically resistant |
| scanning range sd | 100 ... 1000 mm |
| scanning range far limit Sde | 100 ... 1000 mm |
| output circuit | NPN break function (NC) |
| operating temperature | 0 ... +60 °C |
art. 10160414
| special type | chemically resistant |
| scanning range sd | 100 ... 1000 mm |
| scanning range close limit Sdc | 100 ... 1000 mm |
| output circuit | voltage output |
| operating temperature | 0 ... +60 °C |
art. 10155042
| scanning range sd | 60 ... 400 mm |
| scanning range close limit Sdc | 60 ... 400 mm |
| scanning range far limit Sde | 60 ... 400 mm |
| output circuit | current output |
| operating temperature | -10 ... +60 °C |
art. 10142491
| scanning range sd | 10 ... 200 mm |
| scanning range far limit Sde | 30 ... 200 mm |
| hysteresis typ. | 4 % Sde |
| output circuit | PNP break function (NC) |
| operating temperature | -10 ... +60 °C |
art. 10158275
| scanning range sd | 100 ... 1000 mm |
| scanning range close limit Sdc | 100 ... 1000 mm |
| scanning range far limit Sde | 100 ... 1000 mm |
| output circuit | voltage output |
| operating temperature | -10 ... +60 °C |
art. 10146711
| scanning range sd | 20 ... 200 mm |
| scanning range close limit Sdc | 20 ... 200 mm |
| scanning range far limit Sde | 20 ... 200 mm |
| output circuit | voltage output |
| operating temperature | -10 ... +60 °C |
art. 10129046
| scanning range sd | 100 ... 1000 mm |
| scanning range close limit Sdc | 100 ... 1000 mm |
| scanning range far limit Sde | 100 ... 1000 mm |
| output circuit | current output |
| operating temperature | -10 ... +60 °C |
art. 10123379
| scanning range sd | 30 ... 250 mm |
| scanning range far limit Sde | 30 ... 250 mm |
| hysteresis typ. | 4 % Sde |
| output circuit | PNP break function (NC) |
| operating temperature | -25 ... +60 °C |
art. 10125521
| scanning range sd | 100 ... 1000 mm |
| scanning range close limit Sdc | 100 ... 1000 mm |
| scanning range far limit Sde | 100 ... 1000 mm |
| output circuit | voltage output |
| operating temperature | -10 ... +60 °C |
The J14A0, J14A2, J14A3 series are a line of pneumatic cylinders with guides.