• Reliable measurement independent of material color, transparency, gloss and ambient light
  • Four ranges up to 1,300 mm
  • Short plastic M18 housing with a length of 41 mm
  • Integrated time-of-flight technology detects objects such as glass, liquids and transparent foils, independent of color
  • Range up to 8,000 mm
  • Display enables fast and flexible sensor adjustment
  • Integrated time-of-flight technology detects objects such as glass, liquids and transparent foils, independent of color
  • Range up to 8,000 mm
  • Display enables fast and flexible sensor adjustment

art. 10140060

scanning range sd10 ... 200 mm
scanning range far limit Sde30 ... 200 mm
hysteresis typ.4 % Sde
output circuitPNP make function (NO)
operating temperature-10 ... +60 °C

art. 10149127 Baumer ultrasonic sensors

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10134142

scanning range sd400 ... 2500 mm
scanning range close limit Sdc400 ... 2500 mm
scanning range far limit Sde400 ... 2500 mm
output circuitcurrent output
operating temperature-10 ... +60 °C

art. 10129530

scanning range sd400 ... 2500 mm
scanning range close limit Sdc400 ... 2500 mm
scanning range far limit Sde400 ... 2500 mm
output circuitcurrent output
operating temperature-10 ... +60 °C

art. 10130405

scanning range sd350 ... 2500 mm
scanning range far limit Sde350 ... 2500 mm
hysteresis typ.4 % Sde
output circuitNPN make function (NO)
operating temperature-25 ... +60 °C

art. 10156679

scanning range sd400 ... 2500 mm
scanning range close limit Sdc400 ... 2500 mm
scanning range far limit Sde400 ... 2500 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10131880

scanning range sd400 ... 2500 mm
scanning range close limit Sdc400 ... 2500 mm
scanning range far limit Sde400 ... 2500 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10162125

special typechemically resistant
scanning range sd60 ... 400 mm
scanning range close limit Sdc60 ... 400 mm
output circuitcurrent output
operating temperature0 ... +60 °C

art. 10161023

special typechemically resistant
scanning range sd100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitNPN make function (NO)
operating temperature0 ... +60 °C

art. 10161024

special typechemically resistant
scanning range sd100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitNPN break function (NC)
operating temperature0 ... +60 °C

art. 10160414

special typechemically resistant
scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
output circuitvoltage output
operating temperature0 ... +60 °C

art. 10155042

scanning range sd60 ... 400 mm
scanning range close limit Sdc60 ... 400 mm
scanning range far limit Sde60 ... 400 mm
output circuitcurrent output
operating temperature-10 ... +60 °C

art. 10142491

scanning range sd10 ... 200 mm
scanning range far limit Sde30 ... 200 mm
hysteresis typ.4 % Sde
output circuitPNP break function (NC)
operating temperature-10 ... +60 °C

art. 10158275

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10146711

scanning range sd20 ... 200 mm
scanning range close limit Sdc20 ... 200 mm
scanning range far limit Sde20 ... 200 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10129046

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitcurrent output
operating temperature-10 ... +60 °C

art. 10123379

scanning range sd30 ... 250 mm
scanning range far limit Sde30 ... 250 mm
hysteresis typ.4 % Sde
output circuitPNP break function (NC)
operating temperature-25 ... +60 °C

art. 10125521

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

The J14A0, J14A2, J14A3 series are a line of pneumatic cylinders with guides.

  • Non-contact level measurement up to 3.4 m operating distance / 8.0 m limit scanning distance
  • Pressure resistant up to 6 bar (87 psi)
  • Transducer protected by PVDF cover for increased resistance
  • Non-contact level measurement up to 3.4 m operating distance / 8.0 m limit scanning distance
  • Pressure resistant up to 6 bar (87 psi)
  • Transducer protected by PVDF cover for increased resistance

art.10234439

  • emitter
  • scanning range sd: 0 ... 700 mm
  • operating temperature: 0 ... +60 °C

Burkert water filter

  • Filtration rating: Micron level
  • Flow rate: Capacity of the filter


art. 10131013

special type2 point proximity switch
scanning range sd350 ... 2500 mm
scanning range far limit Sde350 ... 2500 mm
output circuitNPN make function (NO)
operating temperature-10 ... +60 °C

art. 10129063

special type2 point proximity switch
scanning range sd350 ... 2500 mm
scanning range far limit Sde350 ... 2500 mm
output circuitNPN make function (NO)
operating temperature-10 ... +60 °C
5/2 sol/sol pbmo 24v pin up