Baumer Inductive Sensors

art. 10139768

mounting typeflush
special typehigh temperature
nominal sensing distance Sn2 mm
output circuitPNP make function (NO)
operating temperature-25 ... +180 °C

art. 10143039

mounting typeflush
special typehigh temperature
nominal sensing distance Sn2 mm
output circuitPNP break function (NC)
operating temperature-25 ... +180 °C

art. 10143354

mounting typeflush
special typehigh temperature
nominal sensing distance Sn5 mm
output circuitPNP make function (NO)
operating temperature-25 ... +180 °C

art. 10153535

mounting typeflush
special typehigh temperature
nominal sensing distance Sn5 mm
output circuitPNP break function (NC)
operating temperature-25 ... +180 °C

art. 10139543

mounting typeflush
nominal sensing distance Sn0,8 mm
hysteresis2 ... 20 % of Sr
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 10140295

mounting typeflush
nominal sensing distance Sn0,8 mm
hysteresis2 ... 20 % of Sr
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 11166747

  • 1 mm
  • NPN make function (NO)
  • wires, 0,5 m
  • -10 ... 70 °C
  • IP 67

art. 11166750

  • 1 mm
  • NPN break function (NC)
  • wires, 0,5 m
  • -10 ... 70 °C
  • IP 67

art. 10134726

mounting typeflush
nominal sensing distance Sn0,8 mm
hysteresis2 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 10140294

mounting typeflush
nominal sensing distance Sn0,8 mm
hysteresis2 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 11166541

  • 1 mm
  • PNP make function (NO)
  • cable, 2 m
  • -10 ... 70 °C
  • IP 67

art. 10137012

mounting typeflush
nominal sensing distance Sn0,8 mm
hysteresis2 ... 20 % of Sr
output circuitPNP break function (NC)
operating temperature-25 ... +75 °C

art. 11166558

  • 1 mm
  • PNP break function (NC)
  • cable, 2 m
  • -10 ... 70 °C
  • IP 67

art. 10144585

mounting typeflush
nominal sensing distance Sn1 mm
hysteresis2 ... 20 % of Sr
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 11082459

mounting typeflush
nominal sensing distance Sn1,6 mm
hysteresis2 ... 20 % of Sr
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 11082450

mounting typeflush
nominal sensing distance Sn1,6 mm
hysteresis2 ... 20 % of Sr
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 11082433

mounting typeflush
nominal sensing distance Sn1,6 mm
hysteresis2 ... 20 % of Sr
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 11082446

mounting typeflush
nominal sensing distance Sn1,6 mm
hysteresis2 ... 20 % of Sr
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 10146174

mounting typeflush
nominal sensing distance Sn1 mm
hysteresis2 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 11107139

mounting typeflush
nominal sensing distance Sn1 mm
hysteresis2 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 11129428

mounting typeflush
nominal sensing distance Sn1 mm
hysteresis2 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 10144583

mounting typeflush
nominal sensing distance Sn1 mm
hysteresis2 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 10152820

mounting typeflush
nominal sensing distance Sn1 mm
hysteresis2 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 10156444

mounting typeflush
nominal sensing distance Sn1 mm
hysteresis2 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 10144448

mounting typeflush
nominal sensing distance Sn1 mm
hysteresis2 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 10144456

mounting typeflush
nominal sensing distance Sn1 mm
hysteresis2 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 10149638

mounting typeflush
nominal sensing distance Sn0,8 mm
hysteresis2 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 10152366

mounting typeflush
nominal sensing distance Sn0,8 mm
hysteresis2 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 11082457

mounting typeflush
nominal sensing distance Sn1,6 mm
hysteresis2 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 11082452

mounting typeflush
nominal sensing distance Sn1,6 mm
hysteresis2 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C