Baumer
Choose a subcategory:
Show all categories
Voltage supply | 9...30 VDC 5 VDC ±5 % 9...26 VDC |
Consumption w/o load | ≤100 mA |
Pulses per revolution | 250...5000 |
Operating temperature | -40...+85 °C |
Heavy duty incremental encoder through hollow shaft, offshore & saewater resistant with rotatble terminal box.
Voltage supply | 9...30 VDC |
Consumption w/o load | ≤200 mA |
Sensing method | Optical |
Operating temperature | -30...+85 °C |
Voltage supply | 9...30 VDC 5 VDC ±5 % |
Consumption w/o load | ≤100 mA |
Pulses per revolution | 720...4000 |
Operating temperature | -30...+85 °C |
Voltage supply | 9...30 VDC 5 VDC ±5 % 9...26 VDC |
Consumption w/o load | ≤100 mA |
Pulses per revolution | 1024 |
Operating temperature | -30...+85 °C |
Voltage supply | 9...26 VDC 5 VDC ±5 % |
Consumption w/o load | ≤100 mA |
Pulses per revolution | 1024...2048 |
Operating temperature | -30...+85 °C |
Voltage supply | 9...26 VDC 5 VDC ±5 % |
Consumption w/o load | ≤100 mA |
Pulses per revolution | 200...10000 |
Operating temperature | -30...+85 °C |
Voltage supply | 9...26 VDC 5 VDC ±5 % |
Consumption w/o load | ≤100 mA |
Pulses per revolution | 64...2048 |
Operating temperature | -20...+85 °C |
Voltage supply | 9...26 VDC 5 VDC ±5 % |
Consumption w/o load | ≤100 mA |
Pulses per revolution | 250...2500 |
Operating temperature | -30...+85 °C |
Voltage supply | 9...26 VDC 5 VDC ±5 % |
Consumption w/o load | ≤100 mA |
Pulses per revolution | 1...5000 |
Operating temperature | -30...+85 °C -25...+85 °C (>3072 pulses per revolution) |
Voltage supply | 9...30 VDC 5 VDC ±5 % |
Consumption w/o load | ≤100 mA |
Pulses per revolution | 500...5000 |
Operating temperature | -40...+100 °C -40...+90 °C (fixed cable) -25...+100 °C (>3072 pulses per revolution) |
Interference immunity | EN 61000-6-2 |
Emitted interference | EN 61000-6-3 |
Voltage supply | 9...30 VDC 5 VDC ±5 % |
Operating temperature | -40...+100 °C -25...+100 °C (>3072 pulses per revolution) |
Voltage supply | 9...30 VDC 5 VDC ±5 % |
Consumption w/o load | ≤100 mA |
Pulses per revolution | 500...5000 |
Operating temperature | -40...+100 °C -25...+100 °C (>3072 pulses per revolution) |
Voltage supply | 9...30 VDC 5 VDC ±5 % |
Consumption w/o load | ≤100 mA |
Pulses per revolution | 500...2500 |
Operating temperature | -40...+100 °C |
Voltage supply | 9...30 VDC 5 VDC ±5 % |
Consumption w/o load | ≤100 mA |
Pulses per revolution | 300...5000 |
Operating temperature | -30...+100 °C -25...+100 °C (>3072 pulses per revolution) |
Incremental encoders - combination HOG 10 + FSL
Voltage supply | 5 VDC ±10 % 9...30 VDC |
Consumption w/o load | ≤90 mA |
Sinewave cycles per turn | 720...5000 |
Operating temperature | -20...+85 °C |
Voltage supply | 5 VDC ±10 % 7...30 VDC |
Consumption w/o load | ≤90 mA |
Sinewave cycles per turn | 1024...5000 |
Operating temperature | -20...+85 °C |
Voltage supply | 5 VDC ±5 % 9...26 VDC |
Consumption w/o load | ≤90 mA |
Sinewave cycles per turn | 1024...5000 |
Operating temperature | -20...+85 °C |
Voltage supply | 5 VDC ±10 % 9...30 VDC |
Consumption w/o load | ≤90 mA |
Sinewave cycles per turn | 1024...5000 |
Operating temperature | -20...+85 °C |
art. 11207845
- Hard anodized cylindric housing corpus for VCXG.I cameras for modular housing to meet Parma and Food & Beverage applications requirements
- optional tube extension with Tube Module 6mm (11185376), Tube Module 12 mm (11185375) or Tube Module 36 mm (11198906).
- thread: M62
- length 56 mm
Baumer incremental optical encoder
Voltage supply | 4.75...30 VDC |
Reverse polarity protection | Yes |
Consumption w/o load | ≤40 mA (24 VDC) ≤130 mA (4.75 VDC) + output load, max. 250 mA |
Operating temperature | -40...+212 °F (-40...+100 °C), (fixed cable): see temperature diagram |
Voltage supply | 4.75...30 VDC |
Reverse polarity protection | Yes |
Consumption w/o load | ≤50 mA (24 VDC) ≤180 mA (5 VDC) + output load, max. 250 mA |
Operating temperature | -40...+212 °F (-40...+100 °C), (fixed cable): see temperature diagram |
Voltage supply | 4.75...30 VDC |
Reverse polarity protection | Yes |
Consumption w/o load | ≤90 mA |
Operating temperature | -40...+212 °F (-40...+100 °C), (fixed cable): see temperature diagram |
- 2048 x 1088 px
- ams (CMOSIS) CMV2000
- 2/3 CMOS
- 105 fps
- Dual Gigabit Ethernet
art. 11173270
- 0 ...2 mm
- voltage output
- cable PUR, 2 m
- 10 ... 60 °C
- IP 67
art. 11173193
- 0 ... 2 mm
- voltage output
- cable PVC, 2 m
- 10 ... 60 °C
- IP 67
art. 11173266
- 0 ... 2 mm
- voltage output
- flylead connector PVC M8, L=200 mm
- 10 ... 60 °C
- IP 67
art. 11214892
- Distance measuring
- 0 ... 3 mm
- PNP / push-pull
- IO-Link
- Cable PUR, 2m
- -20 ... 70 °C
- IP 67