Baumer

Choose a subcategory:
Show all categories

Incremental encodersPOG 10 DN 1024

Baumer POG10 DN 1200 I B5n 14k6x30

art. 11121235

scanning range sd2 ... 82 mm
scanning range close limit Sdc2 ... 82 mm
scanning range far limit Sde2 ... 82 mm
output circuitcurrent output
operating temperature-10 ... +60 °C

art. 10145833

scanning range sd5 ... 70 mm
scanning range far limit Sde5 ... 70 mm
hysteresis typ.4 % Sde
output circuitPNP make function (NO)
operating temperature0 ... +60 °C

art. 11099365

special type2 point proximity switch
scanning range sd600 ... 6000 mm
scanning range far limit Sde600 ... 6000 mm
output circuitPNP make function (NO) / break function (NC)
operating temperature-25 ... +60 °C

IN STOCK!!!

Tether arm T3

  • Accessory for Baumer 11076547
  • Prevents overload of the bearing force
  • Flexible mounting point orientation
  • Adjustable length
  • For bolt 1/4”
Ripple immunity3 Vms
Power-up time≤ 10 s
Power supply8 … 35 V DC

art. 11701127

  • Adapter to connect VCXG and VCXU cameras to existing TXG cabling
  • Split cable M8/8-pin female connectorВto 1x M8/3-pin male connector (power) andВ1x M8/4-pin male connector (I/Os)
  • Protection class IP65/IP67
  • Length 0.4Вm

Absolute encoders AMG 81

Price on Request
One click request
  • For replacement of "PY" or "BC" style tachogenerators
  • Low response time
  • Open circuit voltage 20...100 mV per rpm
  • Very high resistance to shock
  • High signal quality due to patented LongLife technology
  • Recognition of sense of rotation possible via control
  • CSA / C / US approved
Voltage supply range26,5 - 33,1 VDC
supply current≤ 200 mA
temperature range

-25...+70 °C

-25...+85 °C

Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.120 mA (5 VDC, w/o load)
70 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Interface12 parallel outputs
Operating temperature-20...+85 °C
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.60 mA (5 VDC, w/o load)
40 mA (24 VDC, w/o load)
Pulses per revolution4096...320000
Operating temperature-20...+85 °C
Voltage supply5 VDC ±5 %
Consumption typ.100 mA (5 VDC, w/o load)
Sinewave cycles per turn1000...5000
Operating temperature-20...+85 °C
Price on Request
One click request
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.80 mA (5 VDC, w/o load)
60 mA (24 VDC, w/o load)
Pulses per revolution20...5000
Operating temperature-20...+85 °C
Voltage supply5 VDC ±5 %
Consumption typ.100 mA (5 VDC, w/o load)
Sinewave cycles per turn1000...5000
Operating temperature-20...+85 °C
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.80 mA (5 VDC, w/o load)
60 mA (24 VDC, w/o load)
Pulses per revolution10000...320000
Operating temperature-20...+85 °C
Voltage supply10...30 VDC
Consumption w/o load≤80 mA (24 VDC)
Initializing time typ.500 ms after power on
Operating temperature-40...+85 °C (see general informations)
Voltage supply10...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Operating temperature-20...+85 °C
Voltage supply10...30 VDC
Consumption w/o load≤200 mA (24 VDC)
Initializing time≤250 ms after power on
Operating temperature-40...+85 °C (see general informations)
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption w/o load≤150 mA (5 VDC)
≤60 mA (24 VDC)
Initializing time typ.170 ms after power on
Operating temperature-40...+85 °C (see general informations)
InputsSSI clock: Linereceiver RS422
Zero setting input
Voltage supply10...30 VDC
Consumption typ.50 mA (24 VDC, w/o load)
Initializing time≤170 ms after power on
Operating temperature-40...+85 °C
InputsSSI clock
Zero setting input
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.100 mA (5 VDC, w/o load)
50 mA (24 VDC, w/o load)
Initializing time typ.70 ms after power on
Operating temperature-20...+85 °C
InputsSSI clock
Zero setting input
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.100 mA (5 VDC, w/o load)
50 mA (24 VDC, w/o load)
Initializing time typ.70 ms after power on
Operating temperature-40...+65 °C
InputsSSI clock
Zero setting input
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.100 mA (5 VDC, w/o load)
50 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Operating temperature-20...+85 °C
InputsSSI clock
Zero setting input
Voltage supply8...30 VDC
Reverse polarity protectionYes
Short-circuit proofYes
Operating temperature-40...+85 °C
Voltage supply10...30 VDC
Consumption w/o load≤80 mA (24 VDC)
Initializing time typ.500 ms after power on
Operating temperature-40...+85 °C (see general informations)
Voltage supply10...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Initializing time typ.500 ms after power on
Operating temperature-20...+65 °C
Voltage supply10...30 VDC
Consumption w/o load≤200 mA (24 VDC)
Initializing time≤250 ms after power on