Baumer
Choose a subcategory:
Show all categories
Incremental encodersPOG 10 DN 1024
Baumer POG10 DN 1200 I B5n 14k6x30
art. 11080600
art. 11121235
| scanning range sd | 2 ... 82 mm |
| scanning range close limit Sdc | 2 ... 82 mm |
| scanning range far limit Sde | 2 ... 82 mm |
| output circuit | current output |
| operating temperature | -10 ... +60 °C |
art. 10145833
| scanning range sd | 5 ... 70 mm |
| scanning range far limit Sde | 5 ... 70 mm |
| hysteresis typ. | 4 % Sde |
| output circuit | PNP make function (NO) |
| operating temperature | 0 ... +60 °C |
art. 11099365
| special type | 2 point proximity switch |
| scanning range sd | 600 ... 6000 mm |
| scanning range far limit Sde | 600 ... 6000 mm |
| output circuit | PNP make function (NO) / break function (NC) |
| operating temperature | -25 ... +60 °C |
IN STOCK!!!
Tether arm T3
- Accessory for Baumer 11076547
- Prevents overload of the bearing force
- Flexible mounting point orientation
- Adjustable length
- For bolt 1/4”
| Ripple immunity | 3 Vms |
| Power-up time | ≤ 10 s |
| Power supply | 8 … 35 V DC |
art. 11701127
- Adapter to connect VCXG and VCXU cameras to existing TXG cabling
- Split cable M8/8-pin female connectorВto 1x M8/3-pin male connector (power) andВ1x M8/4-pin male connector (I/Os)
- Protection class IP65/IP67
- Length 0.4Вm
Absolute encoders AMG 81
- For replacement of "PY" or "BC" style tachogenerators
- Low response time
- Open circuit voltage 20...100 mV per rpm
- Very high resistance to shock
- High signal quality due to patented LongLife technology
- Recognition of sense of rotation possible via control
- CSA / C / US approved
| Voltage supply range | 26,5 - 33,1 VDC |
| supply current | ≤ 200 mA |
| temperature range | -25...+70 °C -25...+85 °C |
| Voltage supply | 5 VDC ±10 % 10...30 VDC |
| Consumption typ. | 120 mA (5 VDC, w/o load) 70 mA (24 VDC, w/o load) |
| Initializing time typ. | 170 ms after power on |
| Interface | 12 parallel outputs |
| Operating temperature | -20...+85 °C |
| Voltage supply | 5 VDC ±10 % 10...30 VDC |
| Consumption typ. | 60 mA (5 VDC, w/o load) 40 mA (24 VDC, w/o load) |
| Pulses per revolution | 4096...320000 |
| Operating temperature | -20...+85 °C |
| Voltage supply | 5 VDC ±5 % |
| Consumption typ. | 100 mA (5 VDC, w/o load) |
| Sinewave cycles per turn | 1000...5000 |
| Operating temperature | -20...+85 °C |
| Voltage supply | 5 VDC ±10 % 10...30 VDC |
| Consumption typ. | 80 mA (5 VDC, w/o load) 60 mA (24 VDC, w/o load) |
| Pulses per revolution | 20...5000 |
| Operating temperature | -20...+85 °C |
| Voltage supply | 5 VDC ±5 % |
| Consumption typ. | 100 mA (5 VDC, w/o load) |
| Sinewave cycles per turn | 1000...5000 |
| Operating temperature | -20...+85 °C |
| Voltage supply | 5 VDC ±10 % 10...30 VDC |
| Consumption typ. | 80 mA (5 VDC, w/o load) 60 mA (24 VDC, w/o load) |
| Pulses per revolution | 10000...320000 |
| Operating temperature | -20...+85 °C |
| Voltage supply | 10...30 VDC |
| Consumption w/o load | ≤80 mA (24 VDC) |
| Initializing time typ. | 500 ms after power on |
| Operating temperature | -40...+85 °C (see general informations) |
| Voltage supply | 10...30 VDC |
| Consumption typ. | 100 mA (24 VDC, w/o load) |
| Initializing time typ. | 170 ms after power on |
| Operating temperature | -20...+85 °C |
| Voltage supply | 10...30 VDC |
| Consumption w/o load | ≤200 mA (24 VDC) |
| Initializing time | ≤250 ms after power on |
| Operating temperature | -40...+85 °C (see general informations) |
| Voltage supply | 5 VDC ±10 % 10...30 VDC |
| Consumption w/o load | ≤150 mA (5 VDC) ≤60 mA (24 VDC) |
| Initializing time typ. | 170 ms after power on |
| Operating temperature | -40...+85 °C (see general informations) |
| Inputs | SSI clock: Linereceiver RS422 Zero setting input |
| Voltage supply | 10...30 VDC |
| Consumption typ. | 50 mA (24 VDC, w/o load) |
| Initializing time | ≤170 ms after power on |
| Operating temperature | -40...+85 °C |
| Inputs | SSI clock Zero setting input |
| Voltage supply | 5 VDC ±10 % 10...30 VDC |
| Consumption typ. | 100 mA (5 VDC, w/o load) 50 mA (24 VDC, w/o load) |
| Initializing time typ. | 70 ms after power on |
| Operating temperature | -20...+85 °C |
| Inputs | SSI clock Zero setting input |
| Voltage supply | 5 VDC ±10 % 10...30 VDC |
| Consumption typ. | 100 mA (5 VDC, w/o load) 50 mA (24 VDC, w/o load) |
| Initializing time typ. | 70 ms after power on |
| Operating temperature | -40...+65 °C |
| Inputs | SSI clock Zero setting input |
| Voltage supply | 5 VDC ±10 % 10...30 VDC |
| Consumption typ. | 100 mA (5 VDC, w/o load) 50 mA (24 VDC, w/o load) |
| Initializing time typ. | 170 ms after power on |
| Operating temperature | -20...+85 °C |
| Inputs | SSI clock Zero setting input |
| Voltage supply | 8...30 VDC |
| Reverse polarity protection | Yes |
| Short-circuit proof | Yes |
| Operating temperature | -40...+85 °C |
| Voltage supply | 10...30 VDC |
| Consumption w/o load | ≤80 mA (24 VDC) |
| Initializing time typ. | 500 ms after power on |
| Operating temperature | -40...+85 °C (see general informations) |
| Voltage supply | 10...30 VDC |
| Consumption typ. | 100 mA (24 VDC, w/o load) |
| Initializing time typ. | 500 ms after power on |
| Operating temperature | -20...+65 °C |
| Voltage supply | 10...30 VDC |
| Consumption w/o load | ≤200 mA (24 VDC) |
| Initializing time | ≤250 ms after power on |