Baumer

Choose a subcategory:
Show all categories

Baumer TE2 - Compact RTD temperature sensor

  • Compact and rugged design
  • Customer-specific immersion depth down to 3000 mm
  • Precision measurement from -50 ... 250 °C
  • Integrated 4 ... 20 mA transmitter or Pt100 output

Baumer TG 74 d

  • Tachogenerator / ATEX
  • Ex-approved by ATEX II 2 G Ex db eb IIC T6 Gb
  • Low response time
  • Solid shaft ø14 mm
  • EURO flange B10

Baumer TIL

  • Through hollow shaft ø10 to ø16 mm
  • Max. 2048 pulses per revolution
  • Optical sensing method

Baumer TIL Y 1

  • Blind hollow shaft ø12 mm
  • Max. 2048 pulses per revolution
  • V-Lock clamping
  • TTL or HTL output signals

art. 10118863

Contact Form: Double Pole, Single Throw (DPST)
Type: DC
Sensing Type: Proximity Style
Compatible Mounting Type: Surface Mount
Shield: Unshielded
Sensor Type: Solid State
Termination Type: Connector

art. 10234440

emitter / receiverreceiver
scanning range sd0 ... 700 mm
scanning range far limit Sde0 ... 700 mm
output circuitPNP complementary
operating temperature0 ... +60 °C

art. 10140060

scanning range sd10 ... 200 mm
scanning range far limit Sde30 ... 200 mm
hysteresis typ.4 % Sde
output circuitPNP make function (NO)
operating temperature-10 ... +60 °C

art. 10149127 Baumer ultrasonic sensors

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10134142

scanning range sd400 ... 2500 mm
scanning range close limit Sdc400 ... 2500 mm
scanning range far limit Sde400 ... 2500 mm
output circuitcurrent output
operating temperature-10 ... +60 °C

art. 10129530

scanning range sd400 ... 2500 mm
scanning range close limit Sdc400 ... 2500 mm
scanning range far limit Sde400 ... 2500 mm
output circuitcurrent output
operating temperature-10 ... +60 °C

art. 10130405

scanning range sd350 ... 2500 mm
scanning range far limit Sde350 ... 2500 mm
hysteresis typ.4 % Sde
output circuitNPN make function (NO)
operating temperature-25 ... +60 °C

art. 10156679

scanning range sd400 ... 2500 mm
scanning range close limit Sdc400 ... 2500 mm
scanning range far limit Sde400 ... 2500 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10131880

scanning range sd400 ... 2500 mm
scanning range close limit Sdc400 ... 2500 mm
scanning range far limit Sde400 ... 2500 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10161023

special typechemically resistant
scanning range sd100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitNPN make function (NO)
operating temperature0 ... +60 °C

art. 10161024

special typechemically resistant
scanning range sd100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitNPN break function (NC)
operating temperature0 ... +60 °C

art. 10160414

special typechemically resistant
scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
output circuitvoltage output
operating temperature0 ... +60 °C

art. 10155042

scanning range sd60 ... 400 mm
scanning range close limit Sdc60 ... 400 mm
scanning range far limit Sde60 ... 400 mm
output circuitcurrent output
operating temperature-10 ... +60 °C

art. 10142491

scanning range sd10 ... 200 mm
scanning range far limit Sde30 ... 200 mm
hysteresis typ.4 % Sde
output circuitPNP break function (NC)
operating temperature-10 ... +60 °C

art. 10158275

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10146711

scanning range sd20 ... 200 mm
scanning range close limit Sdc20 ... 200 mm
scanning range far limit Sde20 ... 200 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art. 10129046

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitcurrent output
operating temperature-10 ... +60 °C

art. 10123379

scanning range sd30 ... 250 mm
scanning range far limit Sde30 ... 250 mm
hysteresis typ.4 % Sde
output circuitPNP break function (NC)
operating temperature-25 ... +60 °C

art. 10125521

scanning range sd100 ... 1000 mm
scanning range close limit Sdc100 ... 1000 mm
scanning range far limit Sde100 ... 1000 mm
output circuitvoltage output
operating temperature-10 ... +60 °C

art.10234439

  • emitter
  • scanning range sd: 0 ... 700 mm
  • operating temperature: 0 ... +60 °C

art. 10131013

special type2 point proximity switch
scanning range sd350 ... 2500 mm
scanning range far limit Sde350 ... 2500 mm
output circuitNPN make function (NO)
operating temperature-10 ... +60 °C

art. 10129063

special type2 point proximity switch
scanning range sd350 ... 2500 mm
scanning range far limit Sde350 ... 2500 mm
output circuitNPN make function (NO)
operating temperature-10 ... +60 °C
  • art. 11165842
  • 640 x 480 px
  • OnsemiPYTHON300
  • 1/4" CMOS
  • 403 fps
  • Gigabit Ethernet

art. 11051407

  • stand for VeriSens
  • content: articulated arm, baseplate, one white and one black underlayment, VeriSens mounting with 2 screws (hexagon socket)
  • max. hight of device mounting approx. 28 cm

verisens vision sensors

  • User management
  • Password protection
  • Backup & Restore function
  • Download VeriSensВ® Application Suite: www.baumer.com/vs-sw

Baumer X 700 - CANopen®

  • Encoder multiturn / CANopen® / ATEX
  • Optical sensing method
  • Resolution: singleturn 18 bit, multiturn 14 bit
  • Clamping flange with solid shaft ø10 mm
  • Explosion protection per Ex II 2D/2G (ATEX)
  • Device class 2 / zone 1 (gas), zone 21 (dust)