Baumer

Choose a subcategory:
Show all categories
Voltage supply10...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Operating temperature-20...+85 °C
Voltage supply10...30 VDC
Consumption w/o load≤200 mA (24 VDC)
Initializing time≤250 ms after power on
Operating temperature-40...+85 °C (see general informations)
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption w/o load≤150 mA (5 VDC)
≤60 mA (24 VDC)
Initializing time typ.170 ms after power on
Operating temperature-40...+85 °C (see general informations)
InputsSSI clock: Linereceiver RS422
Zero setting input
Voltage supply10...30 VDC
Consumption typ.50 mA (24 VDC, w/o load)
Initializing time≤170 ms after power on
Operating temperature-40...+85 °C
InputsSSI clock
Zero setting input
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.100 mA (5 VDC, w/o load)
50 mA (24 VDC, w/o load)
Initializing time typ.70 ms after power on
Operating temperature-20...+85 °C
InputsSSI clock
Zero setting input
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.100 mA (5 VDC, w/o load)
50 mA (24 VDC, w/o load)
Initializing time typ.70 ms after power on
Operating temperature-40...+65 °C
InputsSSI clock
Zero setting input
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.100 mA (5 VDC, w/o load)
50 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Operating temperature-20...+85 °C
InputsSSI clock
Zero setting input
Voltage supply8...30 VDC
Reverse polarity protectionYes
Short-circuit proofYes
Operating temperature-40...+85 °C
Voltage supply10...30 VDC
Consumption w/o load≤80 mA (24 VDC)
Initializing time typ.500 ms after power on
Operating temperature-40...+85 °C (see general informations)
Voltage supply10...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Initializing time typ.500 ms after power on
Operating temperature-20...+65 °C
Voltage supply10...30 VDC
Consumption w/o load≤200 mA (24 VDC)
Initializing time≤250 ms after power on
Operating temperature-40...+85 °C (see general informations)
Voltage supply10...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Operating temperature-40...+85 °C
Voltage supply10...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Operating temperature-40...+85 °C
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption w/o load≤150 mA (5 VDC)
≤60 mA (24 VDC)
Initializing time typ.170 ms after power on
Operating temperature-40...+85 °C (see general informations)
InputsSSI clock: Linereceiver RS422
Zero setting input
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.100 mA (5 VDC, w/o load)
50 mA (24 VDC, w/o load)
Initializing time typ.70 ms after power on
Operating temperature-20...+85 °C
InputsSSI clock
Zero setting input
Voltage supply10...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Operating temperature-20...+85 °C
Voltage supply10...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Operating temperature-20...+85 °C
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.100 mA (5 VDC, w/o load)
50 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Operating temperature-20...+85 °C
InputsSSI clock
Zero setting input
Voltage supply10...30 VDC
Consumption typ.100 mA (24 VDC, w/o load)
Initializing time typ.500 ms after power on
Operating temperature-20...+65 °C
Voltage supply10...30 VDC
Consumption w/o load≤200 mA (24 VDC)
Initializing time≤250 ms after power on
Operating temperature-40...+85 °C (see general informations)
Voltage supply10...30 VDC
Consumption typ.50 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Interface12 parallel outputs
Operating temperature-20...+85 °C
Voltage supply10...30 VDC
Consumption w/o load≤200 mA (24 VDC)
Initializing time≤250 ms after power on
Operating temperature-40...+85 °C (see general informations)
Voltage supply10...30 VDC
Consumption typ.50 mA (24 VDC, w/o load)
Initializing time typ.170 ms after power on
Interface12 parallel outputs
Operating temperature-20...+85 °C
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption w/o load≤150 mA (5 VDC)
≤60 mA (24 VDC)
Initializing time typ.170 ms after power on
Operating temperature-40...+85 °C (see general informations)
InputsSSI clock: Linereceiver RS422
Zero setting input
Voltage supply5 VDC ±10 %
10...30 VDC
Consumption typ.30 mA (5 VDC, w/o load)
15 mA (24 VDC, w/o load)
Pulses per revolution64...2048
Operating temperature-20...+85 °C

Cable GigE M12X/RJ45, 15.0m. Gigabit Ethernet interface cable (CAT6A) with X-Coded screw lock connector (M12/8-pin), length 15.0 m, weight: ≤ 1050 g

art. 11230359

  • M12, female, A-coded, 12-poles- PUR, 500 cm, shielded, free cable end
  • Dragchain capable
  • Head A: IP67
  • Cable: good resistance against chemicals, flames, oils
  • Halogen free

art. 11230360

  • M12, female, A-coded, 12-poles- PUR, 1000 cm, shielded, free cable end
  • Dragchain capable
  • Head A: IP67
  • Cable: good resistance against chemicals, flames, oils
  • Halogen free

art. 10127191

special typesensor for high temperatures
nominal sensing distance Sn15 mm
nominal sensing distance Sn adjustable4 ... 15 mm
output circuitPNP make function (NO)
operating temperature-40 ... +200 °C

art. 10164642

nominal sensing distance Sn0,5 mm
mounting typenon-flush
GND electrodeno
output circuitNPN make function (NO)
operating temperature0 ... +70 °C