Baumer

Choose a subcategory:
Show all categories

art. 10234520

actual range Sb1200 mm
sensing distance Tw240 mm
light sourcepulsed infrared diode
operating temperature-25 ... +65 °C
actual range Sb (FSE 200C1002)90 mm
sensing distance Tw (FUE 200C1003)25 mm
light sourcepulsed red LED
output circuitanalog 1 ... 5 VDC
operating temperature-20 ... +60 °C

art. 10235364

Diffuse sensor with intensity difference and wave length 880 nm.

art. 10238052

type intensity difference
light sourcepulsed infrared diode
sensing distance Tw< 80 mm
operating temperature-25 ... +65 °C

art. 10234805

type intensity difference
light sourcepulsed infrared diode
sensing distance Tw30 ... 200 mm
operating temperature-25 ... +65 °C

art. 10216308

  • Connector: M12 4 Pin
  • Supply Voltage:10 ... 30 VDC
  • Body Type:Cylindrical

art. 10234807

type intensity difference
light sourcepulsed infrared diode
sensing distance Tw30 ... 200 mm
operating temperature-25 ... +65 °C

art. 10234808

type intensity difference
light sourcepulsed infrared diode
sensing distance Tw30 ... 200 mm
operating temperature-25 ... +65 °C

art. 10129020

type intensity difference
light sourcepulsed infrared diode
sensing distance Tw60 ... 430 mm
operating temperature-25 ... +55 °C

art. 10129021

actual range Sb800 mm
sensing distance Tw150 mm
light sourcepulsed infrared diode
operating temperature-25 ... +55 °C

art. 10129023

type intensity difference
light sourcepulsed infrared diode
sensing distance Tw20 ... 150 mm
operating temperature-25 ... +55 °C

art. 10128875

type intensity difference
light sourcepulsed infrared diode
sensing distance Tw60 ... 430 mm
operating temperature-25 ... +55 °C

art. 10127712

actual range Sb800 mm
sensing distance Tw150 mm
light sourcepulsed infrared diode
operating temperature-25 ... +55 °C

art. 10128111

actual range Sb800 mm
sensing distance Tw150 mm
light sourcepulsed infrared diode
operating temperature-25 ... +55 °C

art. 10127711

type intensity difference
light sourcepulsed infrared diode
sensing distance Tw20 ... 150 mm
operating temperature-25 ... +55 °C

art. 10214415

type intensity difference
light sourcepulsed infrared diode
sensing distance Tw300 ... 1500 mm
operating temperature0 ... +65 °C

art. 10215057

actual range Sb1400 mm
sensing distance Tw230 mm
light sourcepulsed infrared diode
operating temperature0 ... +65 °C

art. 10152090

type intensity difference
light sourcepulsed red LED
sensing distance Tw20 ... 150 mm
operating temperature-20 ... +50 °C

art. 10151057

type intensity difference
light sourcepulsed red LED
sensing distance Tw20 ... 150 mm
operating temperature-20 ... +50 °C

art. 11001229

type intensity difference
light sourcepulsed red LED
sensing distance Tw5 ... 600 mm
operating temperature-25 ... +65 °C

art. 10218479

typeintensity difference
light sourcepulsed infrared diode
sensing distance Tw< 40 mm
operating temperature-25 ... +65 °C

art. 10238047

type intensity difference
light sourcepulsed infrared diode
sensing distance Tw< 80 mm
operating temperature-25 ... +65 °C

art. 10238426

type intensity difference
light sourcepulsed infrared diode
sensing distance Tw0 ... 400 mm
operating temperature-25 ... +65 °C
Voltage supply10...30 VDC
Consumption w/o load≤40 mA
Pulses per revolution5...120
Operating temperature0...+60 °C
Voltage supply5 VDC ±10 %
4.75...30 VDC
10...30 VDC
Reverse polarity protectionYes (4.75...30 VDC)
Consumption w/o load≤30 mA (24 VDC)
≤60 mA (5 VDC)
Operating temperature-25...+85 °C
-40...+85 °C (optional)
Voltage supply5 VDC ±10 %
4.75...30 VDC
10...30 VDC
Reverse polarity protectionYes (4.75...30 VDC)
Consumption w/o load≤30 mA (24 VDC)
≤60 mA (5 VDC)
Operating temperature-25...+100 °C (5 VDC)
-25...+85 °C (24 VDC)
-40...+85 °C (optional)
Voltage supply5 VDC ±10 %
4.75...30 VDC
10...30 VDC
Reverse polarity protectionYes (4.75...30 VDC)
Consumption w/o load≤30 mA (24 VDC)
≤60 mA (5 VDC)
Operating temperature-25...+100 °C (5 VDC)
-25...+85 °C (24 VDC)
-40...+85 °C (optional)
Voltage supply10...30 VDC
Reverse polarity protectionYes
Consumption w/o load≤100 mA (24 VDC)
Operating temperature-25...+85 °C
-40...+85 °C (optional)
Voltage supply10...30 VDC
Reverse polarity protectionYes
Consumption w/o load≤50 mA (24 VDC)
Operating temperature-25...+85 °C
-40...+85 °C (optional)
InputsSSI clock
Control signals UP/DOWN and zero
Voltage supply5 VDC ±10 %
4.75...30 VDC
Reverse polarity protectionYes (4.75...30 VDC)
Consumption w/o load≤30 mA (24 VDC)
≤60 mA (5 VDC)
Operating temperature-25...+85 °C (24 VDC)
-40...+85 °C (optional)