Baumer

Choose a subcategory:
Show all categories
  • Open circuit voltage 10...60В mV per rpm
  • Solid shaft Diam.11В mm
  • EURO flange B10
  • High signal quality due to patented LongLife technology
  • Temperature compensation of tacho voltage as standard
  • Low moment of inertia
  • No auxiliary energy source required
Voltage supply10...30 VDC
Reverse polarity protectionYes
Consumption w/o load≤50 mA (24 VDC)
Operating temperature-25...+85 °C
-40...+85 °C (optional)
GXMMW.A203P32 art. 11032548
Voltage supply10...30 VDC
Reverse polarity protectionYes
Consumption w/o load≤50 mA (24 VDC)
Operating temperature-25...+70 °C
InputsTxD, RxD (RS232)
Control signals UP/DOWN and zero
ENABLE
Voltage supply10...30 VDC
Reverse polarity protectionYes
Consumption w/o load≤50 mA (24 VDC)
Operating temperature-25...+85 °C
-40...+85 °C (optional)
  • Signal level shifting from HTL - TTL or TTL - HTL
  • Isolating signal cables to multiple receivers to avoid earth loops
  • Regenerating of signals when transmitting over long distance
  • For high interference locations
  • Converting standard square-wave signals into fiber-optic signals
  • Each channel is coupled onto fiber-optic easy-to-fit plug
  • 3 different plug versions available
  • Delay time over a 100 m length of fiber-optic is 1 Вµs
  • Except of POF all fiber optic cable usable, e. g. PCF 200 Ојm, silica fiber 50 and 62.5 Ојm
Blind hollow shaft or cone shaft (1:10)
  • Interface DeviceNet
  • Magnetic sensing method
  • Resolution: singleturn 13 bit, multiturn 16 bit
  • Function display via LEDs
  • Multiturn sensing with Energy Harvesting technology "MicroGen", without gear or battery
  • Two-sided bearing system with hybrid bearings
  • Special protection against corrosion CX (C5-M)
Blind hollow shaft or cone shaft (1:10)
  • Interface EtherCAT
  • Magnetic sensing method
  • Resolution: singleturn 13 bit, multiturn 16 bit
  • Function display via LEDs
  • Multiturn sensing with Energy Harvesting technology "MicroGen", without gear or battery
  • Two-sided bearing system with hybrid bearings
  • Special protection against corrosion CX (C5-M)
  • Magnetic sensing method
  • Function display via LEDs
  • Multiturn sensing with Energy Harvesting technology "MicroGen", without gear or battery
  • Two-sided bearing system with hybrid bearings
  • Special protection against corrosion CX (C5-M)
  • Interface CANopenВ®
  • Magnetic sensing method
  • Resolution: singleturn 13 bit, multiturn 16 bit
  • Function display via LEDs
  • Multiturn sensing with Energy Harvesting technology "MicroGen", without gear or battery
  • Two-sided bearing system with hybrid bearings
  • Special protection against corrosion CX (C5-M)
Voltage supply9...30 VDC
Consumption w/o load≤200 mA
Sensing methodOptical
Operating temperature-20...+85 °C
Voltage supply15...30 VDC
Consumption w/o load≤200 mA
Sensing methodOptical
Operating temperature-20...+85 °C
Voltage supply9...26 VDC
5 VDC ±5 %
Consumption w/o load≤100 mA
Pulses per revolution200...10000
Operating temperature-30...+85 °C

art. 11207845

  • Hard anodized cylindric housing corpus for VCXG.I cameras for modular housing to meet Parma and Food & Beverage applications requirements
  • optional tube extension with Tube Module 6mm (11185376), Tube Module 12 mm (11185375) or Tube Module 36 mm (11198906).
  • thread: M62
  • length 56 mm

Baumer incremental optical encoder

Voltage supply4.75...30 VDC
Reverse polarity protectionYes
Consumption w/o load≤90 mA
Operating temperature-40...+212 °F (-40...+100 °C), (fixed cable): see temperature diagram
  • 2048 x 1088 px
  • ams (CMOSIS) CMV2000
  • 2/3 CMOS
  • 105 fps
  • Dual Gigabit Ethernet

art. 11173270

  • 0 ...2 mm
  • voltage output
  • cable PUR, 2 m
  • 10 ... 60 °C
  • IP 67

art. 11173193

  • 0 ... 2 mm
  • voltage output
  • cable PVC, 2 m
  • 10 ... 60 °C
  • IP 67

art. 11173266

  • 0 ... 2 mm
  • voltage output
  • flylead connector PVC M8, L=200 mm
  • 10 ... 60 °C
  • IP 67

art. 11214892

  • Distance measuring
  • 0 ... 3 mm
  • PNP / push-pull
  • IO-Link
  • Cable PUR, 2m
  • -20 ... 70 °C
  • IP 67

art. 11014578

mounting typenon-flush
special typehygienic design
nominal sensing distance Sn3 mm
output circuitNPN make function (NO)
operating temperature-40 ... +80 °C

art. 11014574

mounting typenon-flush
special typehygienic design
nominal sensing distance Sn3 mm
output circuitPNP make function (NO)
operating temperature-40 ... +80 °C

art. 11014608

mounting typeflush
special typehygienic design
nominal sensing distance Sn4 mm
output circuitPNP make function (NO)
operating temperature-40 ... +80 °C