Baumer

Choose a subcategory:
Show all categories

art. 11014590

mounting typeflush
special typehygienic design
nominal sensing distance Sn4 mm
output circuitPNP make function (NO)
operating temperature-40 ... +80 °C

art. 11014616

mounting typequasi-flush
special typehygienic design
nominal sensing distance Sn8 mm
output circuitPNP make function (NO)
operating temperature-40 ... +80 °C

art. 11014600

mounting typequasi-flush
special typehygienic design
nominal sensing distance Sn8 mm
output circuitPNP make function (NO)
operating temperature-40 ... +80 °C

art. 10250306

mounting typeflush
nominal sensing distance Sn1,5 mm
switching frequency< 5 kHz
operating temperature-25 ... +75 °C

art. 10140708

mounting typeflush
nominal sensing distance Sn0,8 mm
hysteresis2 ... 20 % of Sr
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 10140707

mounting typeflush
nominal sensing distance Sn0,8 mm
hysteresis2 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 10146224

mounting typeflush
nominal sensing distance Sn1 mm
hysteresis2 ... 20 % of Sr
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 10146222

mounting typeflush
nominal sensing distance Sn1 mm
hysteresis2 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 10229710

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis3 ... 20 % of Sr
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 10216613

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis3 ... 20 % of Sr
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 10160242

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis3 ... 20 % of Sr
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 10143588

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis2 ... 20 % of Sr
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 10142863

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis2 ... 20 % of Sr
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 10229711

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis3 ... 20 % of Sr
output circuitNPN break function (NC)
operating temperature-25 ... +75 °C

art. 10228207

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis3 ... 20 % of Sr
output circuitNPN break function (NC)
operating temperature-25 ... +75 °C

art. 10142951

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis2 ... 20 % of Sr
output circuitNPN break function (NC)
operating temperature-25 ... +75 °C

art. 10124009

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis3 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 10216132

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis3 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 10157209

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis3 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 10157206

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis3 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 10158669

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis3 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 10142377

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis2 ... 20 % of Sr
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 10229709

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis3 ... 20 % of Sr
output circuitPNP break function (NC)
operating temperature-25 ... +75 °C

art. 10240160

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis3 ... 20 % of Sr
output circuitPNP break function (NC)
operating temperature-25 ... +75 °C

art. 10229452

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis3 ... 20 % of Sr
output circuitPNP break function (NC)
operating temperature-25 ... +75 °C

art. 10158112

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis3 ... 20 % of Sr
output circuitPNP break function (NC)
operating temperature-25 ... +75 °C

art. 10143587

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis2 ... 20 % of Sr
output circuitPNP break function (NC)
operating temperature-25 ... +75 °C

art. 10142952

mounting typeflush
nominal sensing distance Sn2 mm
hysteresis2 ... 20 % of Sr
output circuitPNP break function (NC)
operating temperature-25 ... +75 °C

art. 10150242

mounting typeflush
nominal sensing distance Sn4 mm
hysteresis3 ... 20 % of Sr
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 10147638

mounting typeflush
nominal sensing distance Sn4 mm
hysteresis3 ... 20 % of Sr
output circuitPNP break function (NC)
operating temperature-25 ... +75 °C