Baumer

Choose a subcategory:
Show all categories
Voltage supply5 VDC ±10 %
Reverse polarity protectionYes
Consumption w/o load≤100 mA
Operating temperature-30...+100 °C

Through hollow shaft bearingless encoder diam. 8 … 28 mm with rectangular signal

Voltage supply5 VDC ±5 %
8...26 VDC
Consumption w/o load≤50 mA
Pulses per revolution64...2048
Operating temperature-40...+100 °C (fixed cable)

Bearingless magnetic encoder with sine signal

Voltage supply5 VDC ±10 %
Consumption w/o load≤50 mA
Sinewave cycles per turn64
Operating temperature-40...+100 °C (fixed cable)
Voltage supply8...30 VDC
4.75...30 VDC
Reverse polarity protectionYes
Consumption w/o load≤100 mA
Operating temperature-20...+70 °C

Magnetic ring encoder with rectangular signal

  • Bearingless magnetic encoder
  • Max. 4096 pulses per revolution
  • Output circuits: HTL or TTL
  • Fast, easy and space saving installation
  • Maintenance-free
  • High accuracy - error max. В±0.2В°
  • Rotation speed max. 10000 rpm
  • High resistance to dirt and vibrations

Magnetic ring encoder with sine signal

Voltage supply5 VDC ±10 %
Consumption w/o load≤50 mA
Sinewave cycles per turn128
Operating temperature-40...+100 °C (fixed cable)
Through hollow shaft diam. 20 to diam. 68 mm
  • Bearingless magnetic encoder
  • 128 sinewave cycles per revolution
  • Output circuit: Sine 1 Vpp
  • Fast, easy and space saving installation
  • Maintenance-free
  • High accuracy - error max. В±0.2 В°
  • Rotation speed max. 6000 rpm
  • High resistance to dirt and vibrations

Through hollow shaft encoder diam. 70 to 140 mm

Voltage supply5 VDC ±5 %
8...26 VDC
Consumption w/o load≤50 mA
Pulses per revolution256...8192
Operating temperature-40...+100 °C (fixed cable)

Magnetic encoder with Sine signal, diam. 70 ... 140 mm

Voltage supply5 VDC ±10 %
Consumption w/o load≤50 mA
Sinewave cycles per turn256
Operating temperature-40...+100 °C (fixed cable)
mounting typequasi-flush
measuring distance Sd0 ... 2 mm
resolution< 0,001 mm (stat.)
< 0,005 mm (dynam.)
output circuitvoltage output
operating temperature10 ... +60 °C
mounting typequasi-flush
measuring distance Sd0 ... 2 mm
resolution< 0,001 mm (stat.)
< 0,005 mm (dynam.)
output circuitvoltage output
operating temperature10 ... +60 °C

art. 10144961

mounting typeflush
measuring distance Sd0 ... 4 mm
resolution< 0,005 mm
output circuitvoltage - / current output
operating temperature-10 ... +70 °C

art. 10237474

mounting typeflush
measuring distance Sd1 ... 2 mm
reference distance1,35 ... 1,65 mm
output circuitvoltage output
operating temperature0 ... +60 °C

art. 10147042

mounting typeflush
measuring distance Sd0 ... 4 mm
resolution< 0,005 mm
output circuitvoltage - / current output
operating temperature-10 ... +70 °C

art. 10146855

mounting typeflush
special typelinearized
measuring distance Sd0 ... 4 mm
output circuitvoltage output
operating temperature-10 ... +70 °C

art. 10123624

mounting typeflush
measuring distance Sd2 ... 5 mm
reference distance3,25 ... 3,75 mm
output circuitcurrent output
operating temperature0 ... +60 °C

art. 10123625

mounting typeflush
measuring distance Sd2 ... 3 mm
reference distance2,35 ... 2,65 mm
output circuitcurrent output
operating temperature0 ... +60 °C

art. 10242449

mounting typeflush
measuring distance Sd2 ... 5 mm
reference distance3,25 ... 3,75 mm
output circuitvoltage output
operating temperature0 ... +60 °C

art. 10241153

mounting typeflush
measuring distance Sd2 ... 3 mm
reference distance2,35 ... 2,65 mm
output circuitvoltage output
operating temperature0 ... +60 °C

art. 10154686

mounting typequasi-flush
measuring distance Sd0 ... 1 mm
resolution< 0,001 mm (stat.)
< 0,005 mm (dynam.)
output circuitvoltage output
operating temperature10 ... +60 °C
mounting typequasi-flush
measuring distance Sd0 ... 2 mm
resolution< 0,001 mm (stat.)
< 0,005 mm (dynam.)
output circuitvoltage output
operating temperature10 ... +60 °C
mounting typequasi-flush
measuring distance Sd0 ... 2 mm
resolution< 0,001 mm (stat.)
< 0,005 mm (dynam.)
output circuitcurrent output
operating temperature10 ... +60 °C
mounting typequasi-flush
measuring distance Sd0 ... 2 mm
resolution< 0,001 mm (stat.)
< 0,005 mm (dynam.)
output circuitvoltage output
operating temperature10 ... +60 °C
mounting typequasi-flush
measuring distance Sd0 ... 2 mm
resolution< 0,001 mm (stat.)
< 0,005 mm (dynam.)
output circuitvoltage output
operating temperature10 ... +60 °C
mounting typequasi-flush
measuring distance Sd0 ... 4 mm
resolution< 0,001 mm (stat.)
< 0,005 mm (dynam.)
output circuitcurrent output
operating temperature-10 ... +70 °C
mounting typequasi-flush
measuring distance Sd0 ... 4 mm
resolution< 0,001 mm (stat.)
< 0,005 mm (dynam.)
output circuitcurrent output
mounting typequasi-flush
measuring distance Sd0 ... 4 mm
resolution< 0,0005 mm (stat.)
< 0,001 mm (dynam.)
output circuitcurrent output
operating temperature-10 ... +70 °C

art. 10237278

mounting typeflush
measuring distance Sd1 ... 2 mm
reference distance1,35 ... 1,65 mm
output circuitvoltage output
operating temperature0 ... +60 °C

art. 10145778

mounting typequasi-flush
measuring distance Sd0 ... 4 mm
resolution< 0,001 mm (stat.)
< 0,005 mm (dynam.)
output circuitvoltage output
operating temperature-10 ... +70 °C
mounting typequasi-flush
measuring distance Sd0 ... 4 mm
resolution< 0,0005 mm (stat.)
< 0,001 mm (dynam.)
output circuitvoltage output
operating temperature-10 ... +70 °C