art. 11116612

mounting typequasi-flush
special typefactor 1
nominal sensing distance Sn8 mm
output circuitNPN make function (NO)
operating temperature-25 ... +75 °C

art. 11174188

  • 10 mm
  • PNP make function (NO)
  • connector M12 5 pin
  • -40 ... 75 °C
  • IP 67

art. 11149168

mounting typeflush
special typeenhanced distance (GammaProx)
nominal sensing distance Sn12 mm
output circuitPNP break function (NC)
operating temperature-25 ... +75 °C

art. 11149146

mounting typeflush
special typeenhanced distance (GammaProx)
nominal sensing distance Sn12 mm
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 11149149

mounting typeflush
special typeenhanced distance (GammaProx)
nominal sensing distance Sn12 mm
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 11149142

mounting typeflush
special typeenhanced distance (GammaProx)
nominal sensing distance Sn12 mm
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 11148329

mounting typeflush
special typeenhanced distance (GammaProx)
nominal sensing distance Sn12 mm
output circuitPNP make function (NO)
operating temperature-25 ... +75 °C

art. 11149163

mounting typenon-flush
special typeenhanced distance (GammaProx)
nominal sensing distance Sn15 mm
output circuitPNP break function (NC)
operating temperature0 ... +65 °C

art. 11149133

mounting typenon-flush
special typeenhanced distance (GammaProx)
nominal sensing distance Sn15 mm
output circuitPNP make function (NO)
operating temperature0 ... +65 °C

art. 11197223

  • 0 ... 8 mm
  • voltage output
  • cable, 2 m
  • -40 ... 85 °C
  • Protection class IP68 / IP69K

art. 11179029

  • 0 ... 18 mm
  • current output
  • external Teach-in
  • connector M12
  • -25 ... 75 °C
  • IP 67

art. 11179028

  • 0 ... 18 mm
  • voltage output
  • external Teach-in
  • connector M12
  • -25 ... 75 °C
  • IP 67

art. 11179050

  • 0 ... 24 mm
  • voltage output
  • external Teach-in
  • connector M12
  • -25 ... 75 °C
  • IP 67

art. 11179025

  • 0 ... 24 mm
  • voltage output
  • connector M12
  • -25 ... 75 °C
  • IP 67
Voltage supply5 VDC ±5 %
8...30 VDC
Reverse polarity protectionYes
Consumption w/o load≤100 mA
Operating temperature-20...+70 °C
-20...+100 °C
Voltage supply5 VDC ±5 %
8...30 VDC
Reverse polarity protectionYes
Consumption w/o load≤100 mA
Operating temperature-20...+70 °C
-20...+100 °C
Voltage supply5 VDC ±5 %
8...30 VDC
Reverse polarity protectionYes
Consumption w/o load≤100 mA
Operating temperature-20...+70 °C
-20...+100 °C
Voltage supply5 VDC ±5 %
8...30 VDC
Reverse polarity protectionYes
Consumption w/o load≤100 mA
Operating temperature-20...+70 °C
-20...+100 °C
Through hollow shaft diam. 20 to diam. 68 mm
  • Bearingless magnetic encoder
  • 128 sinewave cycles per revolution
  • Output circuit: Sine 1 Vpp
  • Fast, easy and space saving installation
  • Maintenance-free
  • High accuracy - error max. В±0.2 В°
  • Rotation speed max. 6000 rpm
  • High resistance to dirt and vibrations
mounting typequasi-flush
measuring distance Sd0 ... 2 mm
resolution< 0,001 mm (stat.)
< 0,005 mm (dynam.)
output circuitvoltage output
operating temperature10 ... +60 °C
mounting typequasi-flush
measuring distance Sd0 ... 2 mm
resolution< 0,001 mm (stat.)
< 0,005 mm (dynam.)
output circuitvoltage output
operating temperature10 ... +60 °C

art. 10144961

mounting typeflush
measuring distance Sd0 ... 4 mm
resolution< 0,005 mm
output circuitvoltage - / current output
operating temperature-10 ... +70 °C

art. 10237474

mounting typeflush
measuring distance Sd1 ... 2 mm
reference distance1,35 ... 1,65 mm
output circuitvoltage output
operating temperature0 ... +60 °C

art. 10147042

mounting typeflush
measuring distance Sd0 ... 4 mm
resolution< 0,005 mm
output circuitvoltage - / current output
operating temperature-10 ... +70 °C

art. 10146855

mounting typeflush
special typelinearized
measuring distance Sd0 ... 4 mm
output circuitvoltage output
operating temperature-10 ... +70 °C

art. 10123624

mounting typeflush
measuring distance Sd2 ... 5 mm
reference distance3,25 ... 3,75 mm
output circuitcurrent output
operating temperature0 ... +60 °C

art. 10123625

mounting typeflush
measuring distance Sd2 ... 3 mm
reference distance2,35 ... 2,65 mm
output circuitcurrent output
operating temperature0 ... +60 °C

art. 10242449

mounting typeflush
measuring distance Sd2 ... 5 mm
reference distance3,25 ... 3,75 mm
output circuitvoltage output
operating temperature0 ... +60 °C

art. 10241153

mounting typeflush
measuring distance Sd2 ... 3 mm
reference distance2,35 ... 2,65 mm
output circuitvoltage output
operating temperature0 ... +60 °C

art. 10154686

mounting typequasi-flush
measuring distance Sd0 ... 1 mm
resolution< 0,001 mm (stat.)
< 0,005 mm (dynam.)
output circuitvoltage output
operating temperature10 ... +60 °C