Endress+Hauser Level Sensors

Effective suppression of background radiation and extraneous radiation at the Gammapilot FMG50.
Process pressure absolute / max. overpressure limit

Any

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Max. measurement distance

Unlimited measuring range,
Cascade

Accuracy

+/-1%

Main wetted parts

Non-contact

Radioisotope level measurement system

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Min. density of medium

Any

Max. measurement distance

Unlimited measuring range
Cascade

Min. conductivity of medium

Any

Accuracy

+/-1%

Main wetted parts

Non-contact

Process temperature

Any

Process pressure absolute / max. overpressure limit

Any

Min. density of medium

Any

Min. conductivity of medium

Any

Radioisotope level measurement system

Radioisotope level measurement system

Micropulse level gauge

Accuracy

Rod probe: +/- 2 mm (0.08 in)
Rope probe: +/- 2 mm (0.08 in)

Process temperature

-20...+80 В°C
(-4...+176 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...6 bar,
(Vacuum...87 psi)

Max. measurement distance

Rod: 4 m (13 ft) Min DK>1.6
Rope: 12 m (40 ft) Min DK>1.6

Main wetted parts

Rod probe: 316L, PPS, Viton
Rope probe: 316, PPS, Viton

Micropulse level gauge

Accuracy

Rod probe :+/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft): +/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in)
Coaxial probe: +/- 2 mm (0.08 in)

Process temperature

-50...+200 В°C
(-58...+392 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...40 bar
(Vacuum...580 psi)

Max. measurement distance

Rod: 10 m (33 ft) Min DK>1.6
Rope: 25 m...30 m (82ft...98 ft) Min DK>1.6;
30m...45 m (98ft...148 ft) Min DK>1,9
Coaxial probe: 6 m (20 ft) Min DK>1.4

Main wetted parts

Rod probe:
316L, Alloy C, Ceramic
Rope probe:
316, 316L, Alloy C, Ceramic
Coaxial probe:
316L, Alloy C, Ceramic, PFA

Micropulse level gauge

Accuracy

Rod probe :+/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):
+/- 10 mm (0.39 in)

Process temperature

-50...+200 В°C
(-58...+392 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...40 bar
(Vacuum...580 psi)

Max. measurement distance

Rod:
4 m (13 ft) Min DK>1.6
Rope:
25 m...30 m (82 ft...98 ft) Min DK>1.6;
30 m...45 m (98 ft...148 ft) Min DK>1,9

Main wetted parts

Rod probe:
304, 304L, 316L, PTFE, PFA
Rope probe:
304, 304L, 316, 316L, PTFE, PFA

Micropulse level gauge

Accuracy

Rod probe:+/- 2 mm (0.08 in)

Process temperature

-20...+150 В°C
(-4...+302 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...16 bar
(Vacuum...232 psi)

Max. measurement distance

Rod: 6 m (20 ft)
Min DK>1.6

Main wetted parts

Rod probe:
304, 304L, 316L, PEEK

Micropulse level gauge

Accuracy

Rod probe: +/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):
+/- 10 mm (0.39 in)
Coaxial probe: +/- 2 mm (0.08 in)

Process temperature

XT: -196...+280 В°C
(-321...+536 В°F)
HT: -196...+450 В°C
(-321...+842 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...400 bar
(Vacuum...5800 psi)

Max. measurement distance

Rod:
10 m (33 ft) Min DK>1.6
Rope:
25 m...30 m (82 ft...98 ft) Min DK>1.6;
30 m...45 m (98 ft...148 ft) Min DK >1,9
Coaxial probe: 6 m (20 ft) Min DK>1.4

Main wetted parts

Rod probe:
304, 316L, Alloy C, Ceramic
Rope probe:
304, 316, 316L, Alloy C, Ceramic
Coaxial probe:
304, 316L, Alloy C, Ceramic

Micropulse level gauge

Accuracy

Rod probe :
+/- 2 mm (0.08 in)
Rope probe:
+/- 2 mm (0.08 in)
Coaxial probe:
+/- 2 mm (0.08 in)

Process temperature

-40...+200 В°C
(-40...+392 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...40 bar
(Vacuum...580 psi)

Max. measurement distance

Rod: 4 m (13 ft)
Min DK >1.4
Rope: 10 m (33 ft)
Min DK >1.4
Coaxial: 6 m (20 ft)
Min DK >1.4

Main wetted parts

Rod probe:
316L, PTFE, PFA
Rope probe:
316, 316L, PTFE, PFA
Coaxial probe:
316L, PTFE, PFA

Micropulse level gauge

Accuracy

Rope probe: +/- 2 mm (0.08 in)

Process temperature

40...+120 В°C
(40...+248 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...16 bar
(Vacuum...232 psi)

Max. measurement distance

Rope: 12 m (40 ft)
Min DK >1.4

Main wetted parts

Rope probe:
304, 316, 316Ti, 316L, PEEK, PPS, PA

Micropulse level gauge

Accuracy

Rod probe: +/- 2 mm (0.08 in)
Rope probe <= 15 m (49ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49ft):
+/- 10 mm (0,39 in)

Process temperature

-40...+150 В°C
(-40...+302 В°F)

Process pressure absolute / max. overpressure limit

Vacuum...16 bar
(Vacuum...232 psi)

Max. measurement distance

Rod:
4 m (13 ft) Min DK>1.4
Rope:
20 m...25 m (66 ft...82 ft) Min DK >1.4;
25 m...30 m (82ft...98 ft) Min DK >1.6;
30 m...45 m (98ft...148 ft) Min DK>1,9

Main wetted parts

Rod probe:
316Ti, 316L, PEEK, PPS
Rope probe:
304, 316, 316Ti, 316L, PEEK, PPS, PA

Micropulse level gauge

Micropulse level gauge

Micropulse level gauge

Capacitive level transmitter

Accuracy

< 1%

Process temperature

-40 В°C ... 100 В°C
(-40 В°F ... 212 В°F)

Process pressure absolute / max. overpressure limit

Vacuum ... 10 bar
(Vacuum ... 145 psi)

Max. measurement distance

2.5 m (8 ft)

Main wetted parts

Probe rods:
316L/1.4404 / PP
Option: carbon fibre PP coated

Capacitive level transmitter

Accuracy

Repeatablity 0,1%

Process temperature

-80В°C...200В°C
-112В°F...392В°F

Process pressure absolute / max. overpressure limit

Vacuum ... 100 bar
(Vaccum ... 1450 psi)

Max. measurement distance

0.1 m ... 4.0 m
(0.3 ft ... 13 ft)

Main wetted parts

Insulation material: PTFE,PFA
316L

Capacitive level transmitter

Accuracy

repeatablity 0,1%

Process temperature

-80В°C...200В°C
-112В°F...392В°F

Process pressure absolute / max. overpressure limit

Vacuum ... 100 bar
(Vaccum ... 1450 psi)

Max. measurement distance

0.42 m ... 10.0 m
(1.38 ft ... 33 ft)

Main wetted parts

Insulation material: FEP,PFA
316L

Capacitive level transmitter

Process temperature

-80 В°C ... +200 В°C
(-112 В°F ... +392 В°F)

Process pressure absolute / max. overpressure limit

Vacuum ... 100 bar
(Vacuum ... 1450 psi)

Capacitive level transmitter

Process temperature

-80 В°C ... +200 В°C
(-112 В°F ... +392 В°F)

Process pressure absolute / max. overpressure limit

Vacuum ... 100 bar
(Vacuum ... 1450 psi)

Float level switch

Vibrating point level switch

Process temperature

-40 В°C ... 150 В°C
(-40 В°F ... 302 В°F)

Process pressure absolute / max. overpressure limit

Vacuum ... 40 bar
(Vacuum ... 580 psi)

Min. density of medium

>0,7g/cmВі
(>0,5g/cmВі optional)