Endress+Hauser Level Sensors

Point level transmitter

Point level transmitter

Point level switching unit for Liquiphant FailSafe FTL80, FTL81 and FTL85.

Point level transmitter

Point level switch with intrinsically safe signal circuit for connection to a capacitance sensor.

Point level transmitter
Point level transmitter
Point level transmitter

Vibration transducer

Switching unit with NAMUR input for rail mounting or single installation.

Limit transmitter

Switching unit with intrinsically safe signal circuit for connection to Liquiphant or Soliphant.

Vibration transducer

Point level transmitter
Process transmitter with control unit for Soliwave FQR57/FDR57.

Point level transmitter

Min. density of medium

min. 10 uS

Field converter

Process temperature

-10 В°C ... 100 В°C
(+10 В°F ... +210 В°F)

Process pressure absolute / max. overpressure limit

Vacuum ... 10 bar
(Vacuum ... 145 psi)

Min. conductivity of medium

20 ВµS/cm

Process temperature

-40 В°C ... 135 В°C
(-40 В°F ... 275 В°F)

Process pressure absolute / max. overpressure limit

Vacuum ... 50 bar
(Vacuum ... 725 psi)

Min. conductivity of medium

20 ВµS/cm

Process temperature

-200 В°C ... 250 В°C
(-328 В°F ... 482 В°F)

Process pressure absolute / max. overpressure limit

Vacuum ... 160 bar
(Vacuum ... 2320 psi)

Min. conductivity of medium

20 ВµS/cm

Displacer level gauge

Accuracy

up to 0.4 mm

Process temperature

-200В°C...200В°C
(-328В°F...392В°F)

Process pressure absolute / max. overpressure limit

0,2...6 bar abs

Max. measurement distance

36 m (118 ft)

Main wetted parts

316L, AlloyC276, PTFE

Accuracy

up to 0.4 mm

Process temperature

-200В°C...200В°C
(-328В°F...392В°F)

Process pressure absolute / max. overpressure limit

up to 25 bar (363 psi) abs

Max. measurement distance

47 m (154 ft)

Main wetted parts

316L, AlloyC276, PTFE

Accuracy

up to 0.4 mm

Process temperature

-200В°C...200В°C
(-328В°F...392В°F)

Process pressure absolute / max. overpressure limit

6 bar abs

Max. measurement distance

22 m (72 ft)

Main wetted parts

316L, AlloyC276, PTFE

Process temperature

-40 В°C ... 80 В°C
(-40 В°F ... 176 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 4 bar abs
(10 psi ... 58 psi)

Max. measurement distance

Max. measurement distance

Accuracy

+/- 2mm + 0.17% of measured distance

Main wetted parts

PVDF (IP68 / NEMA6P)

Ultrasonic measurement Time-of-Flight

Process temperature

-40 В°C ... 80 В°C
(-40 В°F ... 176 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 4 bar abs
(10 psi ... 58 psi)

Max. measurement distance

5 m (16ft)

Accuracy

+/- 2mm + 0.17% of measured distance

Main wetted parts

PVDF (fully welded IP68 / NEMA 6P)

Ultrasonic Level Gauge

Ultrasonic Level Gauge

Process temperature

-40 В°C ... 105 В°C
(-40 В°F ... 221 В°F)
30 min: 135 В°C / 275 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 4 bar abs
(10 psi ... 58 psi)

Max. measurement distance

5 m (16 ft)

Accuracy

+/- 2mm + 0.17% of measured distance

Main wetted parts

316L (fully welded IP68 / NEMA 6P)

Ultrasonic Level Gauge

Process temperature

-40 В°C ... 95 В°C
(-40 В°F ... 203 В°F)

Process pressure absolute / max. overpressure limit

0.7 bar ... 4 bar abs
(10 psi ... 58 psi)

Max. measurement distance

10 m (33 ft)

Accuracy

+/- 2mm + 0.17% of measured distance

Main wetted parts

PVDF (fully welded IP68 / NEMA 6P)