IFM Electronic


AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 5/2-way bistable slide valve free from overlapping, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via external 24 V DC, 5/2-way bistable slide valve free from overlapping, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 5/3-way slide valve free from overlapping, closed, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via external 24 V DC, 5/3-way slide valve free from overlapping, closed, Three orientations of the flat cable are possible, AS-i flat cable connection, Addressing socket, Version 2.11 and 3.0 with extended addressing mode

Active ClassicLine module, AS-i flat cable connection, 4 inputs / 3 outputs, Addressing socket, Three orientations of the flat cable are possible, Version 2.11 and 3.0 with extended addressing mode, Sockets M12 x 1, Digital inputs and outputs

Active ClassicLine module, AS-i flat cable connection, 4 inputs / 4 outputs, Only for operation with AS-i masters with the profile M4, Addressing socket, Three orientations of the flat cable are possible, Version 3.0 with extended addressing mode, Sockets M12 x 1, Digital inputs and outputs

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 2 x 3/2-way slide valves free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, Addressing socket, AS-i profile S-7.F.F

AS-i AirBox, 2 inputs / 1 output, AirBox supply via AS-i, 5/2-way slide valve free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, Addressing socket, AS-i profile S-3.F.F

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 2 x 3/2-way slide valves free from overlapping, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection

Active ClassicLine module, AS-i flat cable connection, 4 inputs, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, Three orientations of the flat cable are possible, inputs externally supplied, Sockets M12 x 1


Active ClassicLine module, AS-i flat cable connection, 4 inputs, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, Three orientations of the flat cable are possible, AS-i distribution possible, Sockets M12 x 1

Active ClassicLine module, AS-i flat cable connection, 4 inputs / 3 outputs, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, Three orientations of the flat cable are possible, inputs externally supplied, Sockets M12 x 1

Active ClassicLine module, AS-i flat cable connection, 4 inputs / 4 outputs, Version 3.0 with extended addressing mode, Addressing socket, Only for operation with AS-i masters with the profile M4, Three orientations of the flat cable are possible, inputs externally supplied, Sockets M12 x 1, Digital inputs and outputs

Active ClassicLine module, AS-i flat cable connection, 4 inputs, Addressing socket, Three orientations of the flat cable are possible, Version 2.11 and 3.0 with extended addressing mode, Sockets M12 x 1

Active ClassicLine module, AS-i flat cable connection, 4 inputs, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, Three orientations of the flat cable are possible, Sockets M12 x 1, Digital inputs

Active ClassicLine module, AS-i flat cable connection, 4 inputs / 4 outputs, Only for operation with AS-i masters with the profile M4, Addressing socket, Three orientations of the flat cable are possible, Version 3.0 with extended addressing mode, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection, Sockets M12 x 1

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 2 x 3/2-way slide valves free from overlapping, monostable, Three orientations of the flat cable are possible, Digital inputs, Addressing socket, AS-i profile S-7.F.F, Versions 2.11 and 3.0, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection

AS-i AirBox, 4 inputs / 1 output , AirBox supply via AS-i, 5/2-way slide valve free from overlapping, monostable, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 5/2-way bistable slide valve free from overlapping, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 5/3-way slide valve free from overlapping, closed, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection

Safety switch with guard locking, Normally closed principle, Rotatable actuating head made of metal, Mechanical release on the front, Supply via AS-i / solenoid supply ext. from 24 V DC, M12 connector

Safety switch with guard locking, Normally open principle, Rotatable actuating head made of metal, Mechanical release on the front, Supply via AS-i / solenoid supply ext. from 24 V DC, M12 connector

Safety switch with guard locking, Normally closed principle, Rotatable actuating head made of metal, Mechanical release on the front, Supply via AS-i / solenoid supply from AS-i, M12 connector

Safety switch with guard locking, Normally open principle, Rotatable actuating head made of metal, Mechanical release on the front, Supply via AS-i / solenoid supply from AS-i, M12 connector

IO-Link master with Profinet interface, max. 8 IO-Link ports / max. 12 digital inputs / max. 8 digital outputs, I/O modules for field applications