IFM

Choose a subcategory:
Show all categories

Active AS-i module IP 65, AS-i interface to FC lower parts, 4 inputs Pt100, 4 analogue inputs , temperature Pt100, AS-i profile S-7.3, Connection via cage clamps

I/O modules for field applications, 4 IO-Link ports / 4 digital inputs, Profibus DP interface, Sockets M12 x 1

I/O modules for field applications, 8 inputs, Profibus DP interface, Sockets M12 x 1

Active ProcessLine module, 4 inputs / 3 outputs, Version 2.1 with extended addressing mode, Protection rating IP 69K, high-grade stainless steel, Sockets M12 x 1, Digital inputs and outputs

Active ProcessLine module, 8 digital inputs (2 slaves), Version 2.1 with extended addressing mode, Protection rating IP 69K, high-grade stainless steel, Sockets M12 x 1, Digital inputs

Active AS-i module, 4 inputs 4...20 mA, 4 analogue inputs 4...20 mA, For the connection of 2-wire and 3-wire sensors

Active AS-i module, 4 inputs 4...20 mA, 4 analogue inputs 4...20 mA, For the connection of 2-wire, 3-wire or 4-wire sensors, Electrical isolation

SmartL25 4 AI (C) C IP20

SmartL25 4 AI (V) C IP20

SmartL25 4 AO (C) C IP20

SmartL25 4 AO (V) C IP20

SmartL25 4 AI (Pt100) C IP20

SmartL25 AS-i Repeater II

ac3256

  • Inputs: 1 ms
  • Outputs: 2 ms
  • Power consumption: 2.4 W
  • Dimensions: 120 x 45 x 22.5 mm
  • Weight: 150 g
  • Case material: Plastic
  • Certificates: CE, UL
  • Standards: EN 61131-2, IEC 61131-2

Dual sensor for actuator feedback, 2 inputs / 1 output, 2 inductive position sensors integrated, Version 2.1 with extended addressing mode, ATEX approval, Group II, category 3G, Connector, Sensing range 4 mm

AS-i Profinet gateway with safe preprocessing, Housing for DIN rail mounting, 4 safe local inputs (dual channel) and 4 safe local semiconductor outputs, Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance, Profinet RT device class B, LCD colour display, Integrated safety and non safety PLC, Configuration and setup by configuration software CODESYS V3

AS-i EtherNet/IP gateway with safe preprocessing, Housing for DIN rail mounting, 4 safe local inputs (dual channel) and 4 safe local semiconductor outputs, Ethernet configuration interface with dynamic web interface for configuration and diagnosis including remote maintenance, LCD colour display, Integrated safety and non safety PLC, Configuration and setup by configuration software CODESYS V3

  • AS_Interface_EtherCAT_Gateway_mit_SPS
  • Operating voltage DC 18...32 V
  • DC
  • use as AS-i EtherCAT gateway with safe preprocessing

Active ClassicLine module, AS-i flat cable connection, 4 analogue inputs 4...20 mA, 4 analogue inputs 4...20 mA, For the connection of 2-wire and 3-wire sensors, Three orientations of the flat cable are possible

Active ClassicLine module, AS-i flat cable connection, 4 analogue inputs 4...20 mA, 4 analogue inputs 4...20 mA, For the connection of 2-wire, 3-wire or 4-wire sensors, Electrical isolation, Three orientations of the flat cable are possible

AirBox AS-Interface with quick assembly technology

AS-i AirBox, 2 inputs / 2 outputs, AirBox supply via AS-i, 5/2-way bistable slide valve free from overlapping, Three orientations of the flat cable are possible, AS-i flat cable connection, Addressing socket, AS-i profile S-3.F.F

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 5/2-way bistable slide valve free from overlapping, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via external 24 V DC, 5/2-way bistable slide valve free from overlapping, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 5/3-way slide valve free from overlapping, closed, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via external 24 V DC, 5/3-way slide valve free from overlapping, closed, Three orientations of the flat cable are possible, AS-i flat cable connection, Addressing socket, Version 2.11 and 3.0 with extended addressing mode

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 2 x 3/2-way slide valves free from overlapping, Three orientations of the flat cable are possible, AS-i flat cable connection, Version 2.11 and 3.0 with extended addressing mode, Addressing socket, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection

AS-i AirBox, 4 inputs / 2 outputs, AirBox supply via AS-i, 2 x 3/2-way slide valves free from overlapping, monostable, Three orientations of the flat cable are possible, Digital inputs, Addressing socket, AS-i profile S-7.F.F, Versions 2.11 and 3.0, ATEX approval, Group II, category 3D, Only in conjunction with impact protection housing E7000A or equivalent protection