Pepperl+Fuchs Explosion Protection

Choose a subcategory:
Show all categories
  • 4-channel
  • Inputs Ex ia, Outputs Ex ia
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Analog input, digital input,
    analog output, digital output
  • Supply circuit 21.5 V (4 mA)
  • HART communication via field bus or service bus
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD): one LED per channel
  • Permanently self-monitoring
  • Interface between the I/O modules and the PCS/PLC
  • Com unit for 80 analog or 184 digital channels
  • Communication via PROFIBUS DP
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • HART communication via PROFIBUS DP V1 or service bus
  • Configuration via GSD parameters from the control system
  • Non-volatile memory for configuration and parameter settings
  • Self configuration in redundant systems
  • Permanently self-monitoring
  • Outputs drive to safe state in case of failures
  • Interface between the I/O modules and the PCS/PLC
  • Com unit for 80 analog or 184 digital channels
  • Communication via PROFIBUS DP
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • HART communication via PROFIBUS DP V1 or service bus
  • Configuration via GSD parameters from the control system
  • Non-volatile memory for configuration and parameter settings
  • Self configuration in redundant systems
  • Permanently self-monitoring
  • Outputs drive to safe state in case of failures
  • Interface between the I/O modules and the PCS/PLC
  • Com unit for 80 analog or 184 digital channels
  • Communication via MODBUS RTU
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • HART communication via service bus
  • Configuration via FDT 1.2 DTM
  • Non-volatile memory for configuration and parameter settings
  • Self configuration in redundant systems
  • Permanently self-monitoring
  • Outputs drive to safe state in case of failures
  • Interface between the I/O modules and the PCS/PLC
  • Com unit for 80 analog or 184 digital channels
  • Communication via PROFIBUS DP
  • Module can be exchanged under voltage (hot swap)
  • HART communication via PROFIBUS DP V1 or service bus
  • Installation in suitable enclosures in Zone 1
  • Configuration via FDT 1.2 DTM
  • Configuration in run (CiR) for any PCS
  • Non-volatile memory for configuration and parameter settings
  • Self configuration in redundant systems
  • Permanently self-monitoring
  • Outputs drive to safe state in case of failures
  • Interface between the I/O modules and the PCS/PLC
  • Com unit for 80 analog or 184 digital channels
  • Communication via PROFIBUS DP
  • Installation in suitable enclosures in Zone 1
  • HART communication via PROFIBUS DP V1 or service bus
  • Configuration via FDT 1.2 DTM
  • Configuration in run (CiR) for any PCS
  • Non-volatile memory for configuration and parameter settings
  • Self configuration in redundant systems
  • Permanently self-monitoring
  • Outputs drive to safe state in case of failures
  • Power supply for 95 - 230 V AC
  • Suitable for the supply of FOL, field products (analyzers, level meters etc.)
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Use two power supplies for redundancy
  • Galvanic isolation to mains
  • Power supply for 24 V DC
  • Suitable for the supply of 24 I/O modules and 1 bus coupler
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Power supply for 24 V DC
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Multi range power supply 90 ... 253 V AC
  • Suitable for the supply of 24 I/O modules and 1 bus coupler
  • Use two power supplies for redundancy
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • For 20 analog or 40 digital channels
  • Sensors in Zone 0/Div. 1 (depending on module assembly)
  • Installation in Zone 2, Div. 2 or safe area
  • HART communication via service bus
  • For FOUNDATION Fieldbus H1
  • Configured via the process control system
  • Non-volatile memory for configuration and parameter settings
  • Quick communication set-up
  • Permanently self-monitoring
  • Outputs drive to safe state in case of failures
  • Module can be exchanged under voltage
  • 16-channel
  • Connection board for K-System HART Multiplexer
  • Interface for parallel connections
  • Connection via spring terminals
  • System board for Triconex
  • HART Termination Board (ETP) for Tricon v10 AI module
  • For 16-channel AI cards 3700, 3700A, 3703E and 3721
  • 16-channel
  • Field side: screw terminals, green
  • Control side: ELCO socket, 56-pin
  • System board for Triconex
  • HART Termination Board (ETP) for Tricon AO module
  • For 8-channel AO card 3805E
  • 8-channel
  • Field side: screw terminals, green
  • Control side: ELCO socket, 56-pin
  • 1-channel
  • Field mount module
  • frac12- NPT thread
  • Stainless steel housing
  • Max. surge current (8/20 micro-s) 20 kA
  • 500 V isolation from earth
  • Suitable for hazardous area
  • For any PROFIBUS interface, e.g. Remote I/O, valves, drives, inverters, motors, controllers etc.
  • Full galvanic isolation between field and control room
  • No sparks capable of ignition or hot surfaces due to low light energies
  • Automatic baud rate detection
  • Star, ring, or line topology selectable
  • Bridging of great distances while maintaining high transmission rates
  • 1-channel
  • Field mount module
  • M20 x 1.5 thread
  • Stainless steel housing
  • Max. surge current (8/20 micro-s) 20 kA
  • 500 V isolation from earth
  • Suitable for hazardous area