Fieldbus Power Hub, Power Supply Module

  • Output: 21 ... 23 V/500 mA
  • Voltage limitation for Entity ic and Ex nL
  • With galvanic isolation
  • Installation in Zone 2/Class I, Div. 2
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • High efficiency, low heat dissipation for high packing density
  • Hot swappable in redundant configuration
  • Module exchange without tools during operation

Price on Request
One click request

Fieldbus Power Hub, Power Supply Module

  • Output: 25 ... 28 V/360 mA
  • Universal power supply for most applications
  • With galvanic isolation
  • Installation in Zone 2/Class I, Div. 2
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • High efficiency, low heat dissipation for high packing density
  • Hot swappable in redundant configuration
  • Module exchange without tools during operation

Price on Request
One click request

Fieldbus Power Hub, Power Supply Module

  • Output: 28 ... 30 V/500 mA
  • High-power trunk for high device count and long cable lengths
  • With galvanic isolation
  • Installation in Zone 2/Class I, Div. 2
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • High efficiency, low heat dissipation for high packing density
  • Hot swappable in redundant configuration
  • Module exchange without tools during operation

Price on Request
One click request

PROFIBUS Power Hub, Gateway Module

  • PROFIBUS DP V1 / For 4 segments PA
  • Couples PROFIBUS PA devices transparently to PROFIBUS DP
  • Optional redundant configuration
  • Installation in Zone 2/Class I, Div. 2
  • Up to 12 Mbit/s, auto adapting
  • For redundant and non-redundant masters
  • Supports Flying Redundancy (FR)
  • Cyclic/acyclic data exchange

Price on Request
One click request

PROFINET Power Hub, Gateway Module

  • Gateway PROFINET RT to 4 x PROFIBUS PA segments
  • Up to 32 devices per PROFIBUS PA segment
  • Installation in Zone 2/Class I, Div. 2
  • Ring and system redundancy
  • Integrated webserver for diagnostics

Price on Request
One click request

Basic Segment Coupler

  • Output: 24 ... 26 V/400 mA
  • Couples PROFIBUS PA devices transparently to PROFIBUS DP
  • High-power trunk for high device count and long cable lengths
  • Installation in Zone 2/Class I, Div. 2
  • Up to 1.5 MBit auto-adapting
  • PROFIBUS DP terminator selectable
  • Power Rail support

Price on Request
One click request

Segment Coupler 1

  • Output: 12.6 ... 13.4 V/100 mA
  • Couples PROFIBUS PA devices transparently to PROFIBUS DP
  • Intrinsically safe, Ex ia (FISCO or Entity)
  • Installation in Zone 2/Class I, Div. 2
  • Fixed, high-availability terminator
  • For all non-redundant masters
  • Cyclic/acyclic data exchange

Price on Request
One click request

Voltage adjustment module

  • Series voltage reducing module
  • Removable terminals
  • Polarity reversal protected
  • Installation in cabinet on DIN mounting rail
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA

Price on Request
One click request

Fieldbus Power Supply

  • Output: 12 ... 13 V/220 mA
  • For battery or solar-powered applications
  • For demanding environmental conditions
  • Installation in Zone 2/Class I, Div. 2
  • For FOUNDATION Fieldbus H1
  • Fixed, high-availability terminator
  • Low heat dissipation

Price on Request
One click request

Fieldbus Power Supply

  • Output: 25 ... 27 V/360 mA
  • For most fieldbus applications
  • High-power trunk for high device count and long cable lengths
  • Installation in Zone 2/Class I, Div. 2
  • For FOUNDATION Fieldbus H1
  • Fixed, high-availability terminator
  • No spacing required between modules

Price on Request
One click request

Fieldbus Power Conditioner

  • Output: 14.7 ... 30.7 V/1 A
  • For very high segment load
  • High-power trunk for high device count and long cable lengths
  • Installation only in safe areas
  • For FOUNDATION Fieldbus H1
  • Selectable, high-availability terminator
  • Low heat dissipation
  • Supply via Power Rail

Price on Request
One click request

Fieldbus Power Repeater

  • Output: 24 ... 26 V/400 mA
  • For extension of fieldbus segments
  • High-power trunk for high device count and long cable lengths
  • Installation in Zone 2/Class I, Div. 2
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Fixed, high-availability terminator
  • High efficiency, low heat dissipation
  • Supply via Power Rail

Price on Request
One click request

Fieldbus Power Repeater

  • Power supply of fieldbus segments according to IEC 61158-2
  • Signal repeater for fieldbus topologies in accordance to Entity
  • 70 mA supply of the field side
  • Improves the fieldbus signal
  • Extension of the transmission distance by means of opening a new fieldbus segment
  • Integrated bus terminations
  • Removable terminals and Power Rail connection for simple installation
  • Supply via Power Rail

Price on Request
One click request

Fieldbus Power Repeater

  • Power supply of fieldbus segments according to IEC 61158-2
  • Signal repeater for fieldbus topologies in accordance to FISCO
  • 100 mA supply of the field side
  • Improves the fieldbus signal
  • Extension of the transmission distance by means of opening a new fieldbus segment
  • Integrated bus terminations
  • Removable terminals and Power Rail connection for simple installation
  • Supply via Power Rail

Price on Request
One click request

Advanced Diagnostic Module, Kit for Stand-Alone Operation

  • Comprehensive diagnostics for the fieldbus physical layer
  • Module and motherboard for retrofit of any installation
  • Precise measurements through passive circuits
  • For commissioning, online monitoring and troubleshooting
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Installation in Zone 2/Class I, Div. 2
  • System state and fault indication via LEDs
  • Display of data in the safety of the control room
  • Full software integration into PCS and PAM possible

Price on Request
One click request

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface

  • System integration kit for Advanced Diagnostics
  • PCS integration via Diagnostic Manager or device DTM
  • Simple automatic setup of Advanced Diagnostics
  • Common alarm handling
  • For FOUNDATION Fieldbus and PROFIBUS PA
  • Installation in Zone 2

Price on Request
One click request

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O

  • System integration kit for Advanced Diagnostics
  • PCS integration via Diagnostic Manager or device DTM
  • Simple automatic setup of Advanced Diagnostics
  • Alarm handling and integrated I/O for cabinet monitoring/control
  • For FOUNDATION Fieldbus and PROFIBUS PA
  • Installation in Zone 2

Price on Request
One click request

Starter Kit for FOUNDATION Fieldbus H1 Infrastructure

Complete hardware for connection of FOUNDATION Fieldbus H1 field devices to the host system of your choice

Price on Request
One click request

Starter Kit for PROFIBUS PA Infrastructure

Complete hardware for connection of PROFIBUS PA field devices to a DP-Master

Price on Request
One click request

High-Density Fieldbus Power Hub, Motherboard for Honeywell C-Series

  • 4 segments, redundant, individual modules per segment
  • Customized for Honeywell, C-Series
  • High-power trunk: Live work on devices in any hazardous area
  • Optimized for size and quality, low heat dissipation
  • For FOUNDATION Fieldbus H1
  • Optional advanced diagnostics
  • Passive impedance and CREST technology for high reliability
  • Installation in Zone 2/Div. 2

Price on Request
One click request

Fieldbus Power Hub, Gateway Motherboard

  • For 2 gateway modules
  • For PROFIBUS PA
  • Redundant configuration
  • Installation in Zone 2/Class I, Div. 2
  • Spring terminals or screw terminals selectable

Price on Request
One click request

Compact Fieldbus Power Hub, Motherboard, Common Interface

  • 4 segments, individual modules per segment
  • Supports all PLC and PCS hosts
  • High-power trunk: Live work on devices in any hazardous area
  • Best quality, smallest size and lowest heat dissipation
  • For FOUNDATION Fieldbus H1
  • Optional advanced diagnostics
  • Passive impedance for high reliability
  • Supports Ex ic voltage limitation
  • Installation in Zone 2/Div. 2
  • Spring terminals or screw terminals selectable

Price on Request
One click request

Fieldbus Power Hub, Motherboard for Gateway and Power Supply Modules

  • 4 segments, simplex, individual modules per segment
  • For PROFIBUS PA
  • For gateway and power supply modules
  • High-power trunk: Live work on devices in any hazardous area
  • Optional advanced diagnostics
  • Installation in Zone 2/Class I, Div. 2
  • Spring terminals or screw terminals selectable

Price on Request
One click request

Compact Fieldbus Power Hub, Motherboard, Host System Connector

  • 4 segments, individual modules per segment
  • Customizable cable connections to any PLC and PCS hosts
  • High-power trunk: Live work on devices in any hazardous area
  • Best quality, smallest size and lowest heat dissipation
  • For FOUNDATION Fieldbus and PROFIBUS PA
  • Optional advanced diagnostics
  • Passive impedance for high reliability
  • Supports Ex ic voltage limitation
  • Installation in Zone 2/Div. 2
  • Spring terminals or screw terminals selectable

Price on Request
One click request

Compact Fieldbus Power Hub, Motherboard for Yokogawa ALF111

  • 4 segments, individual modules per segment
  • Customized for Yokogawa, ALF 111
  • High-power trunk: Live work on devices in any hazardous area
  • Best quality, smallest size and lowest heat dissipation
  • For FOUNDATION Fieldbus H1
  • Optional advanced diagnostics
  • Passive impedance for high reliability
  • Supports Ex ic voltage limitation
  • Installation in Zone 2/Div. 2
  • Spring terminals or screw terminals selectable

in international format without spaces