Pepperl+Fuchs Industrial Sensors
Choose a subcategory:
Show all categories
- Gateway compliant with AS-Interface specification 3.0
- Fault diagnosis via LEDs and grafic display
- Easy commissioning by graphic display
- AS-Interface monitor read via display
- Earth fault detection
- AS-Interface noise detection
- Gateway and safety monitor in one housing
- SafeLink
- Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
- Six safe electronic outputs
- Integrated data decoupling
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- Ethernet diagnostic interface
- Connection to CC-Link
- Gateway compliant with AS-Interface specification 3.0
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- Easy commissioning by graphic display
- Commissioning, locally on the gateway or via AS-i Control Tools software
- Fault diagnosis via LEDs and grafic display
- AS-Interface monitor or extended AS-Interface diagnostic read via display
- Ethernet diagnostic interface
- Gateway compliant with AS-Interface specification 3.0
- 2 AS-Interface networks
- Earth fault detection
- AS-Interface noise detection
- Easy commissioning by graphic display
- Commissioning, locally on the gateway or via AS-i Control Tools software
- Fault diagnosis via LEDs and grafic display
- AS-Interface monitor or extended AS-Interface diagnostic read via display
- Gateway and safety monitor in one housing
- Connection to EtherCAT
- SafeLink
- Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
- 2 AS-Interface networks
- Six safe electronic outputs
- Integrated data decoupling
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- Ethernet diagnostic interface
- Gateway compliant with AS-Interface specification 3.0
- Connection to Ethernet Modbus TCP/IP
- Dublicate addressing detection
- Integrated webserver
- Earth fault detection
- AS-Interface noise detection
- Ethernet diagnostic interface
- Integrated switch allows line topology
- DLR technology supports ring topology
- Connection to Ethernet Modbus TCP/IP
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- Ethernet diagnostic interface
- Integrated switch allows line topology
- DLR technology supports ring topology
- AS-Interface POWER24
- Connection to Ethernet Modbus TCP/IP
- 2 AS-Interface networks
- Easy commissioning and fault diagnosis via LEDs and graphic display
- Dublicate addressing detection
- Integrated data decoupling
- Integrated switch allows line topology
- Integrated webserver
- Earth fault detection
- AS-Interface noise detection
- Ethernet diagnostic interface
- DLR technology supports ring topology
- Gateway and safety monitor in one housing
- Gateway compliant with AS-Interface specification 3.0
- Connection to Ethernet Modbus TCP/IP
- AS-Interface safety monitor with extended range of functions
- Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
- Memory card for configuration data
- 2 AS-Interface networks
- 2 safe output relays and 2 safe electronic outputs
- Integrated switch allows line topology
- DLR technology supports ring topology
- Gateway compliant with AS-Interface specification 3.0
- One AS-Interface network
- Web-based configuration
- Commissioning via mobile devices possible
- IIoT-ready thanks to REST API
- Multiprotocol capability for PROFINET and EtherNet/IP
- Gateway compliant with AS-Interface specification 3.0
- 2 AS-Interface networks
- Web-based configuration
- Commissioning via mobile devices possible
- IIoT-ready thanks to REST API
- Multiprotocol capability for PROFINET and EtherNet/IP
- Connection to MODBUS RTU
- Easy commissioning and fault diagnosis via LEDs and graphic display
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- RS 232 diagnosis interface
- Connection to PROFIBUS DP
- Easy commissioning and fault diagnosis via LEDs and graphic display
- PROFIBUS DP V1 support
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- RS 232 diagnosis interface
- Connection to PROFIBUS DP
- PROFIBUS DP V1 support
- Easy commissioning and fault diagnosis via LEDs and graphic display
- Earth fault detection
- AS-Interface noise detection
- Connection to PROFIBUS DP
- PROFIBUS DP V1 support
- Easy commissioning and fault diagnosis via LEDs and graphic display
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- Ethernet diagnostic interface
- Connection to PROFIBUS DP
- Easy commissioning and fault diagnosis via LEDs and graphic display
- PROFIBUS DP V1 support
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- AS-Interface POWER24
The Product is no Longer Available!
- 2 AS-Interface networks
- PROFIBUS DP V1 support
- Connection to PROFIBUS DP
- 2 AS-Interface networks
- PROFIBUS DP V1 support
- Easy commissioning and fault diagnosis via LEDs and graphic display
- Earth fault detection
- AS-Interface noise detection
- Connection to PROFIBUS DP
- 2 AS-Interface networks
- Integrated data decoupling
- PROFIBUS DP V1 support
- Easy commissioning and fault diagnosis via LEDs and graphic display
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- Connection to PROFIBUS DP
- 2 AS-Interface networks
- PROFIBUS DP V1 support
- Easy commissioning and fault diagnosis via LEDs and graphic display
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- Ethernet diagnostic interface
- Connection to PROFIBUS DP
- 2 AS-Interface networks
- PROFIBUS DP V1 support
- Easy commissioning and fault diagnosis via LEDs and graphic display
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- Ethernet diagnostic interface
- Gateway compliant with AS-Interface specification 3.0
- Compact stainless steel housing
- 7-segment display of addresses and error messages
- Connection to PROFIBUS DP
- Commissioning, without PROFIBUS communication
- All AS-Interface functions possible via PROFIBUS
- Gateway and safety monitor in one housing
- Gateway compliant with AS-Interface specification 3.0
- Connection to PROFIBUS DP
- AS-Interface safety monitor with extended range of functions
- Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
- Memory card for configuration data
- 2 safe output relays and 2 safe electronic outputs
- Gateway and safety monitor in one housing
- Gateway compliant with AS-Interface specification 3.0
- Connection to PROFIBUS DP
- AS-Interface safety monitor with extended range of functions
- Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
- Memory card for configuration data
- 2 AS-Interface networks
- 2 safe output relays and 2 safe electronic outputs
- Gateway and safety monitor in one housing
- Connection to PROFIBUS DP
- SafeLink
- Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
- 2 AS-Interface networks
- 2 safe output relays and 2 safe electronic outputs
- Integrated data decoupling
- Diagnostics via RJ45 Ethernet port
- Gateway compliant with AS-Interface specification 3.0
- Connection to PROFINET IO
- Fault diagnosis via LEDs and grafic display
- Easy commissioning by graphic display
- AS-Interface monitor or extended AS-Interface diagnostic read via display
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- All AS-Interface functions possible via Ethernet
- Commissioning, locally on the gateway or via AS-i Control Tools software
- Ethernet diagnostic interface
- Gateway compliant with AS-Interface specification 3.0
- Connection to PROFINET IO
- Earth fault detection
- Fault diagnosis via LEDs and grafic display
- Compact stainless steel housing
- Connection to PROFINET IO
- Conformance Class B
- Easy commissioning by graphic display
- AS-Interface monitor or extended AS-Interface diagnostic read via display
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- All AS-Interface functions possible via Ethernet
- Ethernet diagnostic interface
- AS-Interface POWER24
- Connection to PROFINET IO
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- Ethernet diagnostic interface
- 2 AS-Interface networks
- Integrated data decoupling
- Integrated webserver
- Integrated switch allows line topology
- Connection to PROFINET IO
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- 2 AS-Interface networks
- Integrated web server with extended functionality