Pepperl+Fuchs Intrinsic Safety Barriers

Choose a subcategory:
Show all categories
  • 1-channel isolated barrier
  • 24 V DC supply (loop powered)
  • Current limit 65 mA at 9.8 V DC
  • Up to SIL 3 acc. to IEC 61508
  • 2-channel isolated barrier
  • 24 V DC supply (loop powered)
  • Current limit 45 mA at 10 V DC
  • Up to SIL 3 acc. to IEC 61508
  • 2-channel isolated barrier
  • 24 V DC supply (loop powered)
  • Current limit 45 mA at 12 V DC
  • Up to SIL 3 acc. to IEC 61508
  • 1-channel signal conditioner
  • 24 V DC supply (loop powered)
  • 2- or 3-wire Pt100 RTD input
  • Output 4 mA ... 20 mA, temperature linearization selectable
  • DIP switch selectable ranges
  • Sensor breakage detection
  • 1-channel isolated barrier
  • 24 V DC supply (loop powered)
  • 2- or 3-wire Pt100 RTD input
  • Output 4 mA ... 20 mA, temperature linearization selectable
  • DIP switch selectable ranges
  • Sensor breakage detection
  • 1-channel signal conditioner
  • 24 V DC supply (loop powered)
  • Thermocouple input
  • Output 4 mA ... 20 mA
  • Internal cold junction compensation
  • Sensor breakage detection
  • DIP switch selectable ranges
  • 1-channel isolated barrier
  • 24 V DC supply (loop powered)
  • Thermocouple input
  • Output 4 mA ... 20 mA
  • Internal cold junction compensation
  • Sensor breakage detection
  • DIP switch selectable ranges

p&f kfd2

  • Installation: KFD2 barriers can be mounted on a DIN rail or on a wall.
  • Operating temperature range: -20 °C to +60 °C
  • Humidity: 95% at 40 °C
  • Vibration resistance: 0.3 g RMS
  • Noise: <60 dBA

pepperl fuchs kfd2 sr2

  • Mechanical protection: IP67
  • Thermal protection: overheating protection
  • Electromagnetic compatibility: meets EMC requirements
  • Signal transmission rate: up to 10 Hz.
  • Resource: up to 10 billion switching operations.
  • 1-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Current input 0 mA ... 20 mA
  • Current output 0 mA ... 20 mA
  • Accuracy 0.1 %
  • Up to SIL 2 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Current input 0 mA ... 20 mA
  • Current output 0 mA ... 20 mA
  • Accuracy 0.1 %
  • Up to SIL 2 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Current input 4 mA ... 20 mA
  • Voltage output 0 V ... 10 V
  • Accuracy 0.1 %
  • Up to SIL 2 acc. to IEC 61508
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Voltage input 0 V ... 10 V
  • Current output 4 mA ... 20 mA
  • Accuracy 0.1 %
  • 1-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Input 2-wire and 3-wire transmitters and 2-wire current sources
  • Output 0/4 mA ... 20 mA
  • Accuracy 0.1 %
  • Up to SIL 2 acc. to IEC 61508
  • 1-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Input 2-wire and 3-wire transmitters and 2-wire current sources
  • Signal splitter (1 input and 2 outputs)
  • Dual output 0/4 mA ... 20 mA
  • Accuracy 0.1 %
  • Up to SIL3 acc. to IEC 61508
  • 1-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Input 2-wire and 3-wire transmitters and 2-wire current sources
  • Output 0/4 mA ... 20 mA
  • 2 relay contact outputs
  • Adjustable energized/de-energized delay
  • Programmable high/low alarm
  • Linearization function (max 20 points)
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Relay contact and transistor output
  • Adjustable output timer functions from 10 ms ... 60 min
  • Input frequency up to 80 Hz- pulse divider up to 1 kHz
  • Reset function
  • Configurable by keypad
  • Line fault detection (LFD)
  • 1-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Input frequency 1 mHz ... 12 kHz
  • 2 relay contact outputs
  • Start-up override
  • Configurable by keypad
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Input frequency 1 mHz ... 5 kHz
  • 2 relay contact outputs
  • Start-up override
  • Configurable by keypad
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • Interface for Power Rail
  • Used for redundant configuration
  • Supply current le- 4 A
  • Replaceable fuse
  • Relay contact output, reversible
  • LED status indication
  • Connection via spring terminals
  • Interface for Power Rail
  • Supply current le- 4 A
  • Replaceable fuse
  • Relay contact output, reversible
  • LED status indication
  • Connection via spring terminals
  • 1-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Level sensing input
  • Adjustable range 1 k&Omega- ... 30 k&Omega-
  • Relay contact output
  • Minimum/maximum control
  • 2-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Level sensing input
  • Adjustable range 1 k Omega- ... 150 k Omega-
  • Relay contact output
  • Adjustable time delay up to 10 s
  • Minimum/maximum control
  • Line fault detection (LFD)

The Product is no longer available!

  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • RS 232 input/output
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Thermocouple, RTD, potentiometer or voltage input
  • Redundant TC input
  • Current output 0/4 mA ... 20 mA
  • 2 relay contact outputs
  • Configurable by PACTware or keypad
  • Line fault (LFD) and sensor burnout detection
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • HART field device input with transmitter power supply
  • Usable as signal splitter (1 input and several outputs)
  • 2 relay contact outputs (change-over contacts)
  • 3 analog outputs 4 mA ... 20 mA
  • Sink and source mode output
  • Configurable by keypad
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • HART field device input with transmitter power supply
  • Usable as signal splitter (1 input and several outputs)
  • 4 relay contact outputs (NO contact)
  • 3 analog outputs 4 mA ... 20 mA
  • Sink and source mode output
  • Configurable by keypad