Pepperl+Fuchs Intrinsic Safety Barriers
Choose a subcategory:
Show all categories
- 1-channel isolated barrier
- 24 V DC supply (bus or loop powered)
- Output 40 mA at 12 V DC, 55 mA current limit
- Contact or logic control input
- Entity parameter Io/Isc = 110 mA
- Line fault detection (LFD)
- Test pulse immunity
- Up to SIL 2 acc. to IEC 61508 (bus powered)
- Up to SIL 3 acc. to IEC 61508 (loop powered)
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Output 40 mA at 12 V DC, 55 mA current limit
- Contact or logic control input
- Entity parameter Io/Isc = 110 mA
- Line fault detection (LFD)
- Test pulse immunity
- Up to SIL 2 acc. to IEC 61508 (bus powered)
- System board for Schneider, Foxboro FBM series
- For 8 modules
- For 8-channel cards FBM201/214(b)/216(b) (AI), FBM215/218/237 (AO), FBM204/205 (AO/AI), FBM244 (AI/AO), FBM247/248 (UIO)
- 24 V DC supply
- Recommended modules: HiC2025 (AI), HiC2031 (AO), HiC2081 (TI), HiC2883 (DO), HiC2441 (UIO)
- Hazardous area: screw terminals, blue
- Non-hazardous area: Sub-D connector (male), 25-pin
Termination Board
Termination Board
- For 8 modules
- 24 V DC supply
- Supported signal types: DI/DO/AI/TI/AO
- Hazardous area: screw terminals, blue
- Non-hazardous area: screw terminals, black
Termination Board
- For 8 modules
- 24 V DC supply
- Supported signal types: DI/DO/AI/TI/AO
- Hazardous area: screw terminals, blue
- Safe area: Sub-D connector (male), 37-pin
Termination Board
- System board for Schneider, Foxboro FBM series
- For 16 modules
- For 32-channel DI card FBM217
- 24 V DC supply
- Recommended module: HiC2842 (DI)
- Hazardous area: screw terminals, blue
- Non-hazardous area: Sub-D connector (male), 37-pin
Termination Board
Termination Board
- For 16 modules
- 24 V DC supply
- Supported signal types: DI/DO/AI/TI/AO
- Hazardous area: screw terminals, blue
- Non-hazardous area: screw terminals, black
Termination Board
- System board for Yokogawa CENTUM VP
- For 32-channel DI card ADV151
- For 16 modules
- Recommended modules: HiC2822 (DI), HiC2842 (DI)
- 24 V DC supply
- Hazardous area: spring terminals, blue
- Safe area: Yokogawa system connector, 50-pin
Termination board
- System board for Yokogawa CENTUM VP
- For 16-channel AI card AAI141
- For 16 modules
- Recommended module: HiC2025 (AI)
- 24 V DC supply
- Hazardous area: spring terminals, blue
- Safe area: Yokogawa system connector, 40-pin
Termination Board
- System board for Yokogawa ProSafe-RS
- For 16-channel DI card SDV144
- For 16 modules
- Recommended modules: HiC2831R1 (DI), HiC2853R1 (DI)
- 24 V DC supply
- Hazardous area: spring terminals, blue
- Safe area: Yokogawa system connector, 50-pin
- System board for Yokogawa ProSafe-RS
- For 16-channel AI card SAI143
- For 16 modules
- Recommended module: HiC2025 (AI)
- 24 V DC supply
- Hazardous area: spring terminals, blue
- Safe area: Yokogawa system connector, 40-pin
- System board for Yokogawa ProSafe-RS
- For 16-channel AI card SAV144
- For 16 modules
- Recommended module: HiC2025 (AI)
- 24 V DC supply
- Hazardous area: spring terminals, blue
- Safe area: Yokogawa system connector, 40-pin
- System board for Yokogawa CENTUM VP
- For 32-channel DO card ADV551
- For 32 modules
- Recommended module: HiC2871 (DO)
- 24 V DC supply
- Hazardous area: spring terminals, blue
- Safe area: Yokogawa system connector, 50-pin
This item is out of production!
- 2-channel isolated barrier
- 24 V DC supply (bus powered)
- Current and voltage input
- Analog current and voltage output
- Sink and source mode outputs
- SMART pass-through
This item is out of production!
- 2-channel isolated barrier
- 24 V DC supply (bus powered)
- Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources
- Output 0/4 mA ... 20 mA current source
- Up to SIL 2 acc. to IEC 61508
This item is out of production!
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- 2-wire SMART transmitter
- Output for 4 mA ... 20 mA or 1 V ... 5 V
- Low power dissipation
- Up to SIL 2 acc. to IEC 61508
This item is out of production!
- 2-channel isolated barrier
- 24 V DC supply (bus powered)
- 2-wire SMART transmitter
- Output for 4 mA ... 20 mA or 1 V ... 5 V
- Low power dissipation
- Up to SIL 2 acc. to IEC 61508
This item is out of production!
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- 2-wire SMART transmitters or current sources
- Output for 4 mA ... 20 mA or 1 V ... 5 V
- Line fault detection (LFD)
- Up to SIL 2 acc. to IEC 61508
This item is out of production!
- 2-channel isolated barrier
- 24 V DC supply (bus powered)
- 2-wire SMART transmitters or current sources
- Usable as signal splitter (1 input and 2 outputs)
- Dual output 4 mA ... 20 mA, current sink
- Line fault detection (LFD)
- Up to SIL 2 acc. to IEC 61508
This item is out of production!
- 2-channel isolated barrier
- 24 V DC supply (bus powered)
- Current output up to 750 Omega- load
- Low power dissipation
This item is out of production!
- 2-channel isolated barrier
- 24 V DC supply (loop powered)
- Current input/output 1.5 mA ... 50 mA
- Fire detector or I/P supply
- Accuracy 0.1 %
- Conformal coating