Pepperl+Fuchs Intrinsic Safety Barriers

Choose a subcategory:
Show all categories
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Input for NAMUR sensors or dry contacts
  • 2-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Input frequency 1 mHz ... 1 kHz
  • Current output 0/4 mA ... 20 mA
  • Relay contact and transistor output
  • Start-up override
  • Configurable by PACTware or keypad
  • Line fault detection (LFD)
  • 1-channel signal conditioner

  • 24 V DC supply (Power Rail)

  • Scaleable current or voltage input

  • 2-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Thermocouple, RTD, potentiometer or voltage input
  • Usable as signal splitter (1 input and 2 outputs)
  • Voltage output 0/1 V ... 5 V
  • Configurable by PACTware
  • Line fault (LFD) and sensor burnout detection
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • 1-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • Thermocouple, RTD, potentiometer or voltage input

  • 1-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • 1-channel isolated barrier

  • 24 V DC supply (Power Rail)

  • Voltage input 0 V ... -20 V

  • 1-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Strain gauge input (full or half bridge)
  • Output 0 mA ... ?± 20 mA or 0 V ... ?± 10 V
  • 2 relay contact outputs
  • Programmable high/low alarm
  • Configurable by PACTware or keypad
  • RS-485 interface
  • Line fault detection (LFD)
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Strain gauge input (full or half bridge)
  • Output 0 mA ... В± 20 mA or 0 V ... В± 10 V
  • 2 relay contact outputs
  • Programmable high/low alarm
  • Configurable by PACTware or keypad
  • RS-485 interface
  • Low response time
  • Line fault detection (LFD)
  • 1-channel signal conditioner
  • Universal usage at different power supplies
  • Thermocouple, RTD, potentiometer or voltage input
  • Redundant TC input
  • Current output 0/4 mA ... 20 mA
  • 2 relay contact outputs
  • Configurable by PACTware or keypad
  • Line fault (LFD) and sensor burnout detection
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • 1-channel signal conditioner
  • Universal usage at different power supplies
  • Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts
  • Input frequency 1 mHz ... 10 kHz
  • Current output 0/4 mA ... 20 mA
  • Relay contact and transistor output
  • Start-up override
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508/IEC 61511
  • 1-channel signal conditioner
  • Universal usage at different power supplies
  • Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts
  • Input frequency 1 mHz ... 10 kHz
  • Current output 0/4 mA ... 20 mA
  • Relay contact and transistor output
  • Start-up override
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508/IEC 61511

KFU8-UFC-EX1.D art. 231197

Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3

  • 2-channel signal conditioner
  • Universal usage at different power supplies
  • Dry contact or NAMUR inputs
  • Input frequency 1 mHz ... 1 kHz
  • Current output 0/4 mA ... 20 mA
  • Relay contact and transistor output
  • Start-up override
  • Configurable by PACTware or keypad
  • Line fault detection (LFD)
  • 2-channel
  • AC version
  • Working voltage 10 V at 10 &micro-A
  • Series resistance max. 1033 &Omega-
  • Fuse rating 50 mA
  • DIN rail mounting

This item is out of production!

  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • 2-wire SMART transmitter
  • Output for 4 mA ... 20 mA or 1 V ... 5 V
  • Sink or source mode
  • Line fault detection (LFD)
  • Up to SIL 3 acc. to IEC 61508

KFD2 CD2 EX1

  • Marking: space for marking on the front panel
  • Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1:2013 (industrial premises)
  • Degree of protection: IEC 60529:2001
  • Protection against electric shock: UL 61010-1:2004
  • Ambient temperature: -20...60 °C (-4...140 °F)
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Level sensing input
  • Adjustable range 1 k Omega- ... 150 k Omega-
  • Relay contact output
  • Fault relay contact output
  • Adjustable time delay up to 10 s
  • Minimum/maximum control
  • Line fault detection (LFD)
  • 2-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Current output up to 700 Omega- load
  • HART I/P and valve positioner
  • Line fault detection (LFD)
  • Accuracy 0.05 %
  • Terminal blocks with test sockets
  • Up to SIL 2 acc. to IEC 61508
  • 2-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Usable as signal splitter (1 input and 2 outputs)
  • 2 x 2 relay contact outputs with AND logic
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 acc. to IEC 61508
  • 2-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Input 2-wire SMART transmitters
  • Output 0/4 mA ... 20 mA current sink
  • Terminal blocks with test sockets
  • Up to SIL 2 acc. to IEC 61508

This item is out of production!

  • Product is phased out and cannot be ordered!!!

    1-channel isolated barrier
  • 24 V DC supply (bus or loop powered)
  • Output 60 mA at 13 V DC, 65 mA current limit
  • Gas group IIB
  • Contact or logic control input
  • Line fault detection (LFD) with separate output
  • Up to SIL 2 acc. to IEC 61508 (bus powered)
  • Up to SIL 3 acc. to IEC 61508 (loop powered)
Zener barrier
HART Interface Solutions
  • Honeywell specific system cable for Honeywell Experion Series C GI/IO to Pepperl+Fuchs H-System termination boards
  • Connects terminal plug on Honeywell Series C GI/IO TA to a single 37-pin Sub-D connector on H-System termination boards
  • 20 m cable length
HART Interface Solutions
HART Interface Solutions
HART Interface Solutions