Pepperl+Fuchs Intrinsic Safety Barriers
Choose a subcategory:
Show all categories
HART Interface Solutions
HART Interface Solutions
- 2-channel
- NAMUR sensor input
- Reduces field wiring by 50%
- Supports 2:1 technology
- 2-channel
- Dry contact input
- Reduces field wiring by 50%
- Supports 2:1 technology
- 1-channel
- Dry contact input
- For line fault detection (LFD)
- System board for Honeywell Universal Safety IO
- System board for Honeywell Universal Process IO
- For 16-channel cards USIO and UPIO
- For 16 modules
- Recommended modules: HiC2831R2 (DI), HiC2853R2 (DI), HiC2871 (DO), HiC2025 (AI), HiC2031 (AO)
- Recommended system cable: CAB-HON-**-S37C32-MX-01000
- 24 V DC supply
- Hazardous area: pluggable screw terminals, blue
- Non-hazardous area: Sub-D connector (male), 37-pin
For Cold Junction Compensation of HiC2081
For Cold Junction Compensation of HiD2081, HiD2082
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Input for 2-wire SMART transmitters and current sources
- Output for 4 mA ... 20 mA or 1 V ... 5 V
- Low power dissipation
- Up to SIL 2 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Input for 2-wire SMART transmitters and current sources
- Output for 4 mA ... 20 mA or 1 V ... 5 V
- Low power dissipation
- Reduced intrinsically safe parameters
- Up to SIL 2 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Input for 2-wire SMART transmitters and current sources
- Output for 4 mA ... 20 mA or 1 V ... 5 V
- Low power dissipation
- Line fault detection (LFD)
- Up to SIL 3 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Input for 2-wire SMART transmitters and current sources
- Output for 4 mA ... 20 mA or 1 V ... 5 V
- Low power dissipation
- Suitable for long field cables (> 1000 m)
- Up to SIL 2 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Current output up to 650 Omega- load
- Low power dissipation
- Up to SIL 2 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Current output up to 625 Omega- load
- HART I/P and valve positioner
- Low power dissipation
- Suitable for long field cables (> 1000 m)
- Up to SIL 2 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply
- Resistance and RTD input (Pt100, Pt500, Pt1000)
- Resistance output
- Accuracy 0.1 %
- Line fault detection (LFD) for Pt100
- Up to SIL 2 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Thermocouple, RTD, potentiometer or voltage input
- Linearized output 4 mA ... 20 mA, sink/source
- Sensor breakage detection
- Configurable by PACTware
- Line fault detection (LFD)
- Up to SIL 2 acc. to IEC 61508/IEC 61511
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Analog input, digital input,
analog output, digital output - No configuration required, device is self-adapting
- HART transparency
- Low power dissipation
- 3-way isolation
- Up to SIL 2 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Dry contact or NAMUR inputs
- Usable as signal splitter (1 input and 2 outputs)
- Relay contact output
- Fault relay contact output
- Line fault detection (LFD)
- Up to SIL 2 acc. to IEC 61508
- 2-channel isolated barrier
- 24 V DC supply (bus powered)
- Dry contact or NAMUR inputs
- 2 relay contact outputs
- Line fault detection (LFD)
- Up to SIL 2 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Dry contact or NAMUR input
- Usable as signal splitter (1 input and 2 outputs)
- 2 passive transistor outputs (resistive acc. to EN 60947-5-6)
- Line fault transparency (LFT)
- Up to SIL 2 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Dry contact or NAMUR inputs
- Application-specific outputs
- Usable as signal splitter (1 input and 2 outputs)
- 2 passive transistor outputs (resistive)
- Line fault transparency (LFT)
- Up to SIL 2 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Dry contact or NAMUR inputs
- Application-specific outputs
- Usable as signal splitter (1 input and 2 outputs)
- 2 passive transistor outputs (resistive)
- Line fault transparency (LFT)
- Up to SIL 2 acc. to IEC 61508
- 2-channel isolated barrier
- 24 V DC supply (bus powered)
- Dry contact or NAMUR inputs
- Application-specific outputs
- 2 passive transistor outputs (resistive)
- Line fault transparency (LFT)
- Up to SIL 2 acc. to IEC 61508
- 2-channel isolated barrier
- 24 V DC supply (bus powered)
- Dry contact or NAMUR inputs
- 2 passive transistor outputs
- Line fault detection (LFD)
- Reversible mode of operation
- Up to SIL 2 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Input for approved dry contacts or SN/S1N sensors
- Active voltage output
- Passive transistor output (resistive acc. to EN 60947-5-6)
- Line fault transparency (LFT)
- Up to SIL 3 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Input for approved dry contacts or SN/S1N sensors
- Active voltage output
- Passive transistor output (resistive)
- Line fault transparency (LFT)
- Up to SIL 3 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (loop powered)
- Output 45 mA at 12 V DC
- Up to SIL 3 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (bus or loop powered)
- Output 40 mA at 12 V DC, 55 mA current limit
- Contact or logic control input
- Entity parameter Io/Isc = 110 mA
- Line fault detection (LFD)
- Test pulse immunity
- Up to SIL 2 acc. to IEC 61508 (bus powered)
- Up to SIL 3 acc. to IEC 61508 (loop powered)
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Output 40 mA at 12 V DC, 55 mA current limit
- Contact or logic control input
- Entity parameter Io/Isc = 110 mA
- Line fault detection (LFD)
- Test pulse immunity
- Up to SIL 2 acc. to IEC 61508 (bus powered)
- System board for Schneider, Foxboro FBM series
- For 8 modules
- For 8-channel cards FBM201/214(b)/216(b) (AI), FBM215/218/237 (AO), FBM204/205 (AO/AI), FBM244 (AI/AO), FBM247/248 (UIO)
- 24 V DC supply
- Recommended modules: HiC2025 (AI), HiC2031 (AO), HiC2081 (TI), HiC2883 (DO), HiC2441 (UIO)
- Hazardous area: screw terminals, blue
- Non-hazardous area: Sub-D connector (male), 25-pin