Pepperl+Fuchs Intrinsic Safety Barriers

Choose a subcategory:

Show all categories
  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Input for 2-wire SMART transmitters and current sources
  • Signal splitter (1 input and 2 outputs)
  • Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V
  • Up to SIL 3 acc. to IEC 61508
  • System board for HIMA, HIMax
  • For 16-channel card X-AO 1601 (AO, single mode)
  • 16-channel card X-AO 1601 (AO, redundant mode on request)
  • For 16 modules
  • Recommended module: HiC2031 (AO)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Safe area: HIMA system connector, 96-pin
  • System board for Triconex (approval TAN48)
  • For 32-channel AI cards 3700A, and 3721
  • For 16 modules
  • Recommended module: HiC2025 (AI)
  • 24 V DC supply
  • Hazardous area: pluggable screw terminals, blue
  • Safe area: ELCO socket, 56-pin
  • System board for Yokogawa CENTUM VP
  • For 16-channel AI/AO card AAB841
  • For 16 modules
  • Recommended modules: HiC2025 (AI), HiC2031 (AO)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Safe area: Yokogawa system connector, 40-pin
  • System board for HIMA, HIMax
  • For 32-channel cards X-AI 32 01 or X-AI 32 02 (AI)
  • For 32 modules
  • Recommended modules: HiC2025 (AI), HiC2081 (TI)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Safe area: HIMA system connector, 96-pin
  • System board for HIMA, HIMax
  • For 32-channel cards X-DI 32 01 or X-DI 32 04 (DI)
  • For 32 modules
  • Recommended modules: HiC2821 (DI), HiC2841 (DI)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Safe area: HIMA system connector, 96-pin
  • System board for HIMA, HIMax
  • For 32-channel card X-DO 32 01 (DO)
  • For 32 modules
  • Recommended module: HiC2873 (DO)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Safe area: HIMA system connector, 96-pin
  • System board for HIMA, HIMax
  • For 32-channel cards X-AI 32 01 or X-AI 32 02 (AI)
  • For 32 modules
  • Recommended module: HiC2027 (AI)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Safe area: HIMA system connector, 96-pin
  • Safe area: spring terminals, black
  • System board for Triconex (approval TAN48)
  • For 64-channel (32+32) AI cards 3704E and 3720
  • For 32 modules
  • Recommended module: HiC2025 (AI)
  • 24 V DC supply
  • Hazardous area: pluggable screw terminals, blue
  • Safe area: ELCO socket, 56-pin
  • System board for Triconex (approval TAN48)
  • For 64-channel (32+32) DI card 3564
  • For 32 modules
  • Recommended module: HiC2821 (DI)
  • 24 V DC supply
  • Hazardous area: pluggable screw terminals, blue
  • Safe area: ELCO socket, 56-pin
  • 4-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Analog in or analog out signals
  • Sink and source mode outputs
  • SMART pass-through
  • Up to SIL 2 acc. to IEC 61508
  • 2-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Current output up to 750 Omega- load
  • SMART I/P and valve positioners
  • Suitable for Yokogawa PCS system
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508
  • System board for HIMA, HIMax
  • For 32-channel cards X-AI 32 01 or X-AI 32 02 (AI)
  • For 16 modules
  • Recommended module: HiD2030 (AI), HiD2082 (Temp.)
  • 24 V DC supply
  • Hazardous area: spring terminals, blue
  • Safe area: HIMA system connector, 96-pin
  • 32-channel
  • 24 V DC supply
  • Interface for serial or parallel wiring options
  • Dual RS 485 connections
  • Slot for HART Multiplexer
  • Ideal for retrofitting existing installations
  • Interface for serial or parallel wiring options
  • 37-pin Sub-D connectors
  • Redundant power supply connections
  • HART filter options
  • Fuse options
  • 32-channel
  • 24 V DC supply
  • For analog output cards
  • HART output filters
  • Interface for serial or parallel wiring options
  • 37-pin Sub-D connectors
  • Slot for HART Multiplexer
  • IA 200 replacement FTA
  • Designed for FBMs 201, 204, 215 and 237
  • 25-pin Sub-D connectors, PCS wiring
  • Redundant power supply connections
  • Easy to add line impedance
  • TDC 3000 replacement FTA
  • Short-circuit protected
  • Process control system wirings
  • Redundant power supply connections
  • Field terminal blocks that are Honeywell FTA compatible
  • Honeywell ""B"" size footprint
  • TDC 3000 replacement FTA
  • Short-circuit protected
  • Redundant PCS wirings
  • Redundant power supply connections
  • Field terminal blocks that are Honeywell FTA compatible
  • Honeywell ""B"" size footprint
  • TDC 3000 replacement FTA
  • Short-circuit protected
  • HART analog output filters
  • Redundant PCS wirings
  • Redundant power supply connections
  • Field terminal blocks that are Honeywell FTA compatible
  • Honeywell ""B"" size footprint
  • Triconex 3700A and 3721 replacement FTA
  • 2- or 3-wire or self powered transmitters
  • Outputs: 2 x 16 channels, 0 V ... 10 V differential, DC coupled (makes 32 channels)
  • Short-circuit protected
  • Plug-n-play wiring capabilities
  • Triconex 3700A and 3721 replacement FTA
  • 2- or 3-wire or self powered transmitters
  • Outputs: 2 x 16 channels, 0 V ... 10 V differential, DC coupled (makes 32 channels)
  • Short-circuit protected
  • Plug-n-play wiring capabilities
  • Optimized for use in floating power configurations
  • Triconex 3701 replacement FTA
  • 2- or 3-wire or self powered transmitters
  • Outputs: 2 x 16 channels, 0 V ... 10 V differential, DC coupled (makes 32 channels)
  • Short-circuit protected
  • Plug-n-play wiring capabilities
  • Triconex 3704E and 3720 replacement FTA
  • 2- or 3-wire or self powered transmitters
  • Outputs: 1 x 32 channels, 0 V ... 5 V differential, DC coupled
  • Short-circuit protected
  • Plug-n-play wiring capabilities
  • Triconex 3805E replacement FTA
  • 32 channels of I/O
  • Outputs: 4 x 8 channels, 4 mA ... 20 mA current loop, DC coupled
  • Short-circuit protected
  • HART analog output filters
  • Triconex 3604E replacement FTA
  • Outputs: 2 x 16 channels, 24 V DC, opto-isolated, non commoned
  • Short-circuit protected
  • Plug-n-play wiring capabilities
  • Output: 24 ... 26 V/400 mA
  • Couples PROFIBUS PA devices transparently to PROFIBUS DP
  • High-power trunk for high device count and long cable lengths
  • Installation in Zone 2/Class I, Div. 2
  • Up to 1.5 MBit auto-adapting
  • PROFIBUS DP terminator selectable
  • Power Rail support
  • Output: 12.6 ... 13.4 V/100 mA
  • Couples PROFIBUS PA devices transparently to PROFIBUS DP
  • Intrinsically safe, Ex ia (FISCO or Entity)
  • Installation in Zone 2/Class I, Div. 2
  • Fixed, high-availability terminator
  • For all non-redundant masters
  • Cyclic/acyclic data exchange
  • 16-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Analog or digtial field device inputs
  • Monitors leakage current
  • Fault relay contact output
  • LED status indication
  • Test circuit for validation
  • Parallel connection for easy integration
  • Conformal coating
  • 1-channel signal conditioner
  • 24 V DC supply (Power Rail)
  • Current and voltage input
  • 2 relay contact outputs
  • Programmable high/low alarm
  • Configurable via DIP switches and potentiometer
  • Terminal blocks with test sockets

in international format without spaces
All fields are required