Schneider Electric
Choose a subcategory:
Show all categories
| Product destination | Asynchronous motors |
| Product specific application | Pumping and ventilation machine Severe and standard applications |
| Component name | ATS48 |
| Power supply voltage | 230...415 V (- 15...10 %) |
| Motor power kW | 45 kW at 230 V (connection in the motor supply line) for severe applications 160 kW at 400 V (connection to the motor delta terminals) for standard applications 132 kW at 400 V (connection to the motor delta terminals) for severe applications 110 kW at 400 V (connection in the motor supply line) for standard applications 110 kW at 230 V (connection to the motor delta terminals) for standard applications 90 kW at 400 V (connection in the motor supply line) for severe applications 90 kW at 230 V (connection to the motor delta terminals) for severe applications 55 kW at 230 V (connection in the motor supply line) for standard applications |
| Product destination | Asynchronous motors |
| Product specific application | Pumping and ventilation machine Severe and standard applications |
| Component name | ATS48 |
| Power supply voltage | 230...415 V (- 15...10 %) |
| Motor power kW | 220 kW at 400 V (connection to the motor delta terminals) for standard applications 160 kW at 400 V (connection to the motor delta terminals) for severe applications 132 kW at 400 V (connection in the motor supply line) for standard applications 132 kW at 230 V (connection to the motor delta terminals) for standard applications 110 kW at 400 V (connection in the motor supply line) for severe applications 110 kW at 230 V (connection to the motor delta terminals) for severe applications 75 kW at 230 V (connection in the motor supply line) for standard applications 55 kW at 230 V (connection in the motor supply line) for severe applications |
| Product destination | Asynchronous motors |
| Product specific application | Pumping and ventilation machine Severe and standard applications |
| Component name | ATS48 |
| Power supply voltage | 230...415 V (- 15...10 %) |
| Motor power kW | 30 kW at 400 V (connection to the motor delta terminals) for standard applications 22 kW at 400 V (connection to the motor delta terminals) for severe applications 18.5 kW at 400 V (connection in the motor supply line) for standard applications 18.5 kW at 230 V (connection to the motor delta terminals) for standard applications 15 kW at 400 V (connection in the motor supply line) for severe applications 15 kW at 230 V (connection to the motor delta terminals) for severe applications 9 kW at 230 V (connection in the motor supply line) for standard applications 7.5 kW at 230 V (connection in the motor supply line) for severe applications |
| Product destination | Asynchronous motors |
| Product specific application | Pumping and ventilation machine Severe and standard applications |
| Component name | ATS48 |
| Power supply voltage | 230...415 V (- 15...10 %) |
| Motor power kW | 45 kW at 400 V (connection to the motor delta terminals) for severe applications 30 kW at 400 V (connection in the motor supply line) for standard applications 30 kW at 230 V (connection to the motor delta terminals) for standard applications 22 kW at 400 V (connection in the motor supply line) for severe applications 22 kW at 230 V (connection to the motor delta terminals) for severe applications 15 kW at 230 V (connection in the motor supply line) for standard applications 11 kW at 230 V (connection in the motor supply line) for severe applications 55 kW at 400 V (connection to the motor delta terminals) for standard applications |
ATS48D62Y Schneider Altistart ATS48 Soft Start
| Product destination | Asynchronous motors |
| Product specific application | Pumping and ventilation machine Severe and standard applications |
| Component name | ATS48 |
| Power supply voltage | 230...415 V (- 15...10 %) |
| Motor power kW | 45 kW at 400 V (connection in the motor supply line) for standard applications 45 kW at 230 V (connection to the motor delta terminals) for standard applications 37 kW at 400 V (connection in the motor supply line) for severe applications 37 kW at 230 V (connection to the motor delta terminals) for severe applications 22 kW at 230 V (connection in the motor supply line) for standard applications 18.5 kW at 230 V (connection in the motor supply line) for severe applications 75 kW at 400 V (connection to the motor delta terminals) for standard applications 55 kW at 400 V (connection to the motor delta terminals) for severe applications |
Sizes cm (LxHxW): 17x5,4x15
SOFT-START STOP 6A 200 480V
Sizes cm (LxHxW): 16,5x6,5x18,5
SOFT-START STOP 9A 200 480V
Sizes cm (LxHxW): 15x5,5x17,5
SOFT-START STOP 12A 200 480V
Sizes cm (LxHxW): 17,2x5x15
SOFT-START STOP 22A 200 480V
Sizes cm (LxHxW): 17,5x5,5x15,2
SOFT-START STOP 32A 200 480V
Sizes cm (LxHxW): 19x11,5x18,5
ATV12 0.18KW 120V 1PH HEAT SINK TB