Pepperl+Fuchs NCB10-30GM40-N0-15M Inductive sensor

Pepperl+Fuchs NCB10-30GM40-N0-15M
Item Number: NCB10-30GM40-N0-15M
  • Comfort series
  • 10 mm flush
  • Stainless steel housing
263.20
Quantity
-
+
Total price: 263.20
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments
Ambient temperature-25 ... 100 В°C (-13 ... 212 В°F)
Ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1.
Appropriate typeNCB10-30GM...-N0...
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
CE marking[*PD-Z02585A*]
ATEX marking II 1G Ex ia IIC T6…T1 Ga
The Ex-significant identification is on the enclosed adhesive label
ATEX marking II 1G Ex ia IIC T6…T1 Ga The Ex-related marking can also be printed on the enclosed label.
Rated operating distance10 mm
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure ""tc"" Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Switching frequency0 ... 200 Hz
EAC conformityTR CU 012/2011
CE marking[*PD-Z02585A*]
Effective internal capacitancemax. 105 nF ; a cable length of 10 m is considered.
Installationflush
Connection typecable PVC , 15 m
Degree of protectionIP67
Appropriate typeNCB10-30GM...-N0...
Output type2-wire
Output typeNAMUR
MTTFd1870 a
Housing materialStainless steel 1.4305 / AISI 303
Standard conformityEN 60079-15:2005 Ignition protection category ""n""
Use is restricted to the following stated conditions
Reduction factor rAl 0.35
CSA approvalcCSAus Listed, General Purpose
Effective internal capacitance Cimax. 105 nF ; a cable length of 10 m is considered.
Use in the hazardous areasee instruction manuals
CE marking[*PD-Z02585A*]
Reduction factor r304 0.75
Effective internal inductancemax. 100 µH ; A cable length of 10 m is considered.
Nominal voltage8 V
GeneralThe apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction!
The special conditions must be observed!
The ATEX Directive applies only to the use of apparatus under atmospheric conditions.
If you use the device outside atmospheric conditions, consider that the permissible safety parameters should be reduced.
Effective internal inductancemax. 100 µH ; a cable length of 10 m is considered.
Core cross-section0.75 mm2
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
CCC approvalCCC approval / marking not required for products rated ≤36 V
ATEX marking II 3G Ex ic IIC T6…T1 Gc
The Ex-significant identification is on the enclosed adhesive label
Switching functionNormally closed (NC)
Effective internal inductance Limax. 100 µH ; A cable length of 10 m is considered.
Short-circuit protectionyes
Effective internal capacitancemax. 105 nF ; a cable length of 10 m is considered.
Switching state indicatorall direction LED, yellow
Effective internal capacitancemax. 105 nF ; a cable length of 10 m is considered.
Reverse polarity protectionreverse polarity protected
Reduction factor rCu 0.3
CertificatePF 13 CERT 2895 X
Effective internal inductancemax. 100 µH ; a cable length of 10 m is considered.
Actual operating distance9 ... 11 mm typ.
Diagnostic Coverage (DC)0 %
ATEX marking II 1D Ex ia IIIC T135В°C Da The Ex-related marking can also be printed on the enclosed label.
Sensing facePBT
Effective internal inductancemax. 100 µH ; a cable length of 10 m is considered.
ATEX marking II 3D Ex tc IIIC T80В°C Dc
The Ex-related marking can also be printed on the enclosed label.
Assured operating distance0 ... 8.1 mm
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection category ""ic"" Use is restricted to the following stated conditions
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Storage temperature-40 ... 100 В°C (-40 ... 212 В°F)
Effective internal capacitancemax. 105 nF ; a cable length of 10 m is considered.
Maximum permissible ambient temperature
Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained.
CE marking[*PD-Z02586A*]
CE marking[*PD-Z02585A*]
Hysteresis1 ... 15 typ. 5 %
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Mission Time (TM)20 a
Appropriate typeNCB10-30GM...-N0...

Comments

No comments yet

Write a comment