Pepperl+Fuchs NCN12-18GM50-Z4 Inductive sensor

Pepperl+Fuchs NCN12-18GM50-Z4
Item Number: NCN12-18GM50-Z4

Series: Cylindrical type, Housing diameter: 18 mm, Housing material: brass, nickel-plated, Rated operating distance: 12 mm, Connection type: cable PVC , 2 m, Output type: 2-wire, Installation: non-flush, Type of voltage: DC

Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments

Pepperl+Fuchs NCN12-18GM50-Z4 Video ▶▶▶


General specifications
Switching element functionDC NO
Rated operating distance12 mm
Installationnon-flush
Output polarityDC
Assured operating distance0 ... 9.1 mm
Reduction factor rAl0.5
Reduction factor rCu0.45
Reduction factor r3040.75
Reduction factor rBrass0.55
Nominal ratings
Operating voltage3.5 ... 30 V
Switching frequency0 ... 1000 Hz
Hysteresistyp. 3 %
Reverse polarity protectionreverse polarity-conductive
Short-circuit protectionpulsing
Voltage dropless than or equal to 3.5 V
Temperature drift± 15%
Operating current2 ... 100 mA
Off-state currenttyp. 0.8 mA
Switching state indicatorLED, yellow
Pre-fault indicatorLED, red
Stability control-switch point0,8 sr ... 0,9 sr
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated less than or equal to 36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross-section0.34 mm2
Housing materialbrass, nickel-plated
Sensing facePBT
Housing diameter18 mm
Degree of protectionIP67

Comments

No comments yet

Write a comment

in international format without spaces
All fields are required