Pepperl+Fuchs NCN3-F31-N4-V18-Y223963 Inductive sensor

Pepperl+Fuchs NCN3-F31-N4-V18-Y223963
Item Number: NCN3-F31-N4-V18-Y223963
  • Direct mounting on standard actuators
  • Fixed setting
  • EC-Type Examination Certificate TГњV99 ATEX 1479X
  • Usable up to SIL 2 acc. to IEC 61508
163.10
Quantity
-
+
Total price: 163.10
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments
Effective internal capacitancemax. 100 nF
A cable length of 10 m is considered.
Effective internal capacitancemax. 100 nF
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Mission Time (TM)20 a
Switching frequency0 ... 3 kHz
Type of protectionintrinsic safety
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
Reverse polarity protectionreverse polarity protected
Type of protectionintrinsic safety
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Reduction factor rSt37 1.3
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at Ui = 20 V , Ii = 25 mA , Pi = 34 mW ,
T6 : 75 В°C (167 В°F)
T5 : 90 В°C (194 В°F)
T4 : 100 В°C (212 В°F)
T3 : 100 В°C (212 В°F)
T2 : 100 В°C (212 В°F)
T1 : 100 В°C (212 В°F)
at Ui = 20 V , Ii = 25 mA , Pi = 64 mW ,
T6 : 75 В°C (167 В°F)
T5 : 90 В°C (194 В°F)
T4 : 100 В°C (212 В°F)
T3 : 100 В°C (212 В°F)
T2 : 100 В°C (212 В°F)
T1 : 100 В°C (212 В°F)
at Ui = 20 V , Ii = 52 mA , Pi = 169 mW ,
T6 : 65 В°C (149 В°F)
T5 : 80 В°C (176 В°F)
T4 : 90 В°C (194 В°F)
T3 : 90 В°C (194 В°F)
T2 : 90 В°C (194 В°F)
T1 : 90 В°C (194 В°F)
Output typeNAMUR
Reduction factor rAl 0.5
Storage temperature-40 ... 100 В°C (-40 ... 212 В°F)
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at Ui = 15 V , Ii = 25 mA , Pi = 34 mW ,
T6 : 75 В°C (167 В°F)
T5 : 90 В°C (194 В°F)
T4 : 100 В°C (212 В°F)
T3 : 100 В°C (212 В°F)
T2 : 100 В°C (212 В°F)
T1 : 100 В°C (212 В°F)
at Ui = 15 V , Ii = 25 mA , Pi = 64 mW ,
T6 : 75 В°C (167 В°F)
T5 : 90 В°C (194 В°F)
T4 : 100 В°C (212 В°F)
T3 : 100 В°C (212 В°F)
T2 : 100 В°C (212 В°F)
T1 : 100 В°C (212 В°F)
at Ui = 15 V , Ii = 52 mA , Pi = 169 mW ,
T6 : 65 В°C (149 В°F)
T5 : 80 В°C (176 В°F)
T4 : 90 В°C (194 В°F)
T3 : 90 В°C (194 В°F)
T2 : 90 В°C (194 В°F)
T1 : 90 В°C (194 В°F)
Hysteresistyp. 5 %
Diagnostic Coverage (DC)0 %
Use in the hazardous areasee instruction manuals
Actual operating distance2.7 ... 3.3 mm typ.
Switching state indicatorLED, yellow
Rated operating distance3 mm
CE marking[*PD-Z02585A*]
Degree of protectionIP67
CE marking[*PD-Z02586A*]
Effective internal capacitancemax. 100 nF
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Safety Integrity Level (SIL)SIL 2
Time delay before availability≤ 1.1 ms
UL approvalcULus Listed, General Purpose
MTTFd1470 a
Actuating elementStainless steel 1.4305 / AISI 303
8.5 mm x 8.5 mm x 0.5 mm
Effective internal inductancemax. 100 µH
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Effective internal inductancemax. 100 µH
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Effective internal capacitancemax. 100 nF
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Type of protectionintrinsic safety
Effective internal capacitancemax. 100 nF
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
CE marking[*PD-Z02585A*]
CE marking[*PD-Z02585A*]
CSA approvalcCSAus Listed, General Purpose
CE marking[*PD-Z02585A*]
Installationflush mountable
CCC approvalCCC approval / marking not required for products rated ≤36 V
Reduction factor rBrass 0.6
Reduction factor rCu 0.4
Effective internal inductancemax. 100 µH
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Sensing facePBT
Type of protectionintrinsic safety
Assured operating distance0 ... 2.4 mm
Housing materialPBT
Output type2-wire
Nominal voltage8 V
Effective internal inductancemax. 100 µH
A cable length of 10 m is considered.
Connection (system side)V18 connector
Short-circuit protectionyes
Switching function2 x normally closed (NC)
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at Ui = 15 V , Ii = 25 mA , Pi = 34 mW : 100 В°C (212 В°F)
at Ui = 15 V , Ii = 25 mA , Pi = 64 mW : 100 В°C (212 В°F)
at Ui = 15 V , Ii = 52 mA , Pi = 169 mW : 90 В°C (194 В°F)
Type of protectionintrinsic safety
Reduction factor r304 1
Ambient temperature-25 ... 100 В°C (-13 ... 212 В°F)
Note:
Under the same product name but with a different part no., this product has a predecessor with a restricted temperature range (up to +70 В°C).
The temperature range specified here (up to +100В°C) only applies to sensors with part no. 2239**.
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at Ui = 15 V , Ii = 25 mA , Pi = 34 mW : 100 В°C (212 В°F)
at Ui = 15 V , Ii = 25 mA , Pi = 64 mW : 100 В°C (212 В°F)
at Ui = 15 V , Ii = 52 mA , Pi = 169 mW : 90 В°C (194 В°F)
Effective internal inductancemax. 100 µH
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Equipment protection levelGa , Gb , Gc (ic) , Da , Mb

Comments

No comments yet

Write a comment