Pepperl+Fuchs NJ1,5-F-N-Y195694 Inductive sensor

Pepperl+Fuchs NJ1,5-F-N-Y195694
Item Number: NJ1,5-F-N-Y195694
  • Comfort series
  • 1.5 mm non-flush
Price on Request
Quantity
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Datasheet
  • Alternative numbers
  • PDF
  • Comments
Appropriate typeNJ 1,5-F-N...
Reduction factor r304 0.85
Ambient temperaturecable in motion -5 ... 80 В°C (23 ... 176 В°F) , cable motionless -25 ... 80 В°C (-13 ... 176 В°F)
Switching functionNormally closed (NC)
CSA approvalcCSAus Listed, General Purpose
Sensing facePBT
Core cross-section0.09 mm2
Effective internal capacitancemax. 30 nF ; a cable length of 10 m is considered.
CE marking[*PD-Z02585A*]
UL approvalcULus Listed, General Purpose
Output type2-wire
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Reduction factor rAl 0.4
Use in the hazardous areasee instruction manuals
Rated operating distance1.5 mm
Effective internal inductancemax. 50 µH ; a cable length of 10 m is considered.
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012
Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions
Appropriate typeNJ 1,5-F-N...
Installationnon-flush
ATEX marking II 1D Ex ia IIIC T135В°C Da
The Ex-related marking can also be printed on the enclosed label.
Assured operating distance0 ... 1.22 mm
Degree of protectionIP68
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Effective internal inductancemax. 50 µH ; a cable length of 10 m is considered.
CE marking[*PD-Z02585A*]
Output typeNAMUR
ATEX marking II 2G Ex ia IIC T6...T1 Gb
The Ex-related marking can also be printed on the enclosed label.
Switching frequency0 ... 5000 Hz
Connection typecable PUR , 5 m
Reduction factor rCu 0.3
Hysteresistyp. %
Effective internal capacitancemax. 30 nF ; a cable length of 10 m is considered.
Nominal voltage8 V
Housing materialPBT

Comments

No comments yet

Write a comment