Pepperl+Fuchs NJ40+U1+E2-Y281474 Inductive sensor


Item Number: NJ40+U1+E2-Y281474
- Comfort series
- Overview
- Datasheet
- Alternative numbers
- Comments
Output type | PNP |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
Reverse polarity protection | reverse polarity protected |
Off-state current | 0 ... 0.5 mA typ. 0.01 mA |
Reduction factor rCu | 0.45 |
Short-circuit protection | pulsing |
Diagnostic Coverage (DC) | 0 % |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % |
Housing material | PBT with Viton seals and PVDF screwed connection |
Degree of protection | IP68 |
UL approval | cULus Listed, General Purpose |
Rated operating distance | 40 mm |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Switching function | Normally open (NO) |
Installation | non-flush |
Actual operating distance | 36 ... 44 mm typ. 40 mm |
Reduction factor r304 | 0.8 |
Operating voltage | 10 ... 30 V |
Output polarity | DC |
Sensing face | PBT |
CSA approval | cCSAus Listed, General Purpose |
Operating voltage indicator | LED, green |
Assured operating distance | 0 ... 32.4 mm |
Core cross-section | up to 2.5 mm2 |
MTTFd | 684 a |
Switching frequency | 0 ... 100 Hz |
Operating current | 0 ... 200 mA |
Mission Time (TM) | 20 a |
Hysteresis | 1 ... 10 typ. 5 % |
No-load supply current | ≤ 10 mA |
Switching state indicator | LED, yellow |
Connection type | terminal compartment |
Reduction factor rAl | 0.5 |
Voltage drop | ≤ 2.8 V |
People also buy
Comments
No comments yet