MTTFd13520 a
Output type2-wire
Effective internal inductancemax. 250 µH ; a cable length of 10 m is considered.
Effective internal capacitancemax. 50 µF
A cable length of 10 m is considered.
Effective internal capacitancemax. 50 nF ; a cable length of 10 m is considered.
Depth of immersion (lateral)5 ... 7 typ. 6 mm
Mission Time (TM)20 a
ATEX marking II 2G Ex ia IIC T6…T1 Gb
The Ex-related marking can also be printed on the enclosed label.
Housing materialPBT/PPS
Appropriate typeSJ3,5-...-N...
Nominal voltage8 V
Effective internal inductancemax. 250 µH
A cable length of 10 m is considered.
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
ATEX marking II 1D Ex ia IIIC T135В°C Da
The Ex-related marking can also be printed on the enclosed label.
Slot width3.5 mm
UL approvalcULus Listed, General Purpose
Operating voltage5 ... 25 V
Use in the hazardous areasee instruction manuals
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate.
CE marking[*PD-Z02585A*]
Hysteresis0.41 ... 0.8
Core cross-section0.14 mm2
Output typeNAMUR
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Switching frequency0 ... 500 Hz
CE marking[*PD-Z02585A*]
Switching functionNormally closed (NC)
CSA approvalcCSAus Listed, General Purpose
Degree of protectionIP67
Appropriate typeSJ3,5-...-N...
Connection typeflexible leads LiY , 220 mm
with connector sleeves , 7 mm
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012
Ignition protection ""Intrinsic safety""
Use is restricted to the following stated conditions
Ambient temperature-25 ... 100 В°C (-13 ... 212 В°F)
Diagnostic Coverage (DC)0 %

Comments