Pepperl+Fuchs SJ3,5-N-Y08944 Inductive slot sensor


Item Number: SJ3,5-N-Y08944
- Special version
- Calibration to B+R segment disc
- 1. actual frequency
- Overview
- Datasheet
- Alternative numbers
- Comments
MTTFd | 13520 a |
Output type | 2-wire |
Effective internal inductance | max. 250 µH ; a cable length of 10 m is considered. |
Effective internal capacitance | max. 50 µF A cable length of 10 m is considered. |
Effective internal capacitance | max. 50 nF ; a cable length of 10 m is considered. |
Depth of immersion (lateral) | 5 ... 7 typ. 6 mm |
Mission Time (TM) | 20 a |
ATEX marking | The Ex-related marking can also be printed on the enclosed label. |
Housing material | PBT/PPS |
Appropriate type | SJ3,5-...-N... |
Nominal voltage | 8 V |
Effective internal inductance | max. 250 µH A cable length of 10 m is considered. |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
ATEX marking | The Ex-related marking can also be printed on the enclosed label. |
Slot width | 3.5 mm |
UL approval | cULus Listed, General Purpose |
Operating voltage | 5 ... 25 V |
Use in the hazardous area | see instruction manuals |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. |
CE marking | [*PD-Z02585A*] |
Hysteresis | 0.41 ... 0.8 |
Core cross-section | 0.14 mm2 |
Output type | NAMUR |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
Switching frequency | 0 ... 500 Hz |
CE marking | [*PD-Z02585A*] |
Switching function | Normally closed (NC) |
CSA approval | cCSAus Listed, General Purpose |
Degree of protection | IP67 |
Appropriate type | SJ3,5-...-N... |
Connection type | flexible leads LiY , 220 mm with connector sleeves , 7 mm |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection ""Intrinsic safety"" Use is restricted to the following stated conditions |
Ambient temperature | -25 ... 100 В°C (-13 ... 212 В°F) |
Diagnostic Coverage (DC) | 0 % |
People also buy
Comments
No comments yet