- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Input for 2-wire SMART transmitters and current sources
- Signal splitter (1 input and 2 outputs)
- Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V
- Up to SIL 2 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Input for 2-wire SMART transmitters and current sources
- Signal splitter (1 input and 2 outputs)
- Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V
- Up to SIL 3 acc. to IEC 61508
- 1-channel isolated barrier
- 24 V DC supply (bus powered)
- Dry contact or NAMUR input
- Usable as signal splitter (1 input and 2 outputs)
- 2 passive transistor outputs
- 1-channel isolated barrier
- 24 V DC supply (bus or loop powered)
- Output 45 mA at 12 V DC
- Line fault transparency (LFT)
- Test pulse immunity
- Up to SIL 3 acc. to IEC/EN 61508
- System board for HIMA, HIMax
- For 16-channel card X-AO 1601 (AO, single mode)
- 16-channel card X-AO 1601 (AO, redundant mode on request)
- For 16 modules
- Recommended module: HiC2031 (AO)
- 24 V DC supply
- Hazardous area: spring terminals, blue
- Safe area: HIMA system connector, 96-pin
- System board for Triconex (approval TAN48)
- For 32-channel AI cards 3700A, and 3721
- For 16 modules
- Recommended module: HiC2025 (AI)
- 24 V DC supply
- Hazardous area: pluggable screw terminals, blue
- Safe area: ELCO socket, 56-pin
- System board for Yokogawa CENTUM VP
- For 16-channel AI cards AAI143, AAB141-H
- For 16 modules
- Recommended modules: HiC2025(A) (AI), HiC2081 (TI)
- 24 V DC supply
- Hazardous area: spring terminals, blue
- Non-hazardous area: Yokogawa system connector, 40-pin
- System board for Yokogawa CENTUM VP
- For 16-channel AI/AO card AAB841
- For 16 modules
- Recommended modules: HiC2025 (AI), HiC2031 (AO)
- 24 V DC supply
- Hazardous area: spring terminals, blue
- Safe area: Yokogawa system connector, 40-pin
- System board for HIMA, HIMax
- For 32-channel cards X-AI 32 01 or X-AI 32 02 (AI)
- For 32 modules
- Recommended modules: HiC2025 (AI), HiC2081 (TI)
- 24 V DC supply
- Hazardous area: spring terminals, blue
- Safe area: HIMA system connector, 96-pin
This item is out of production!
- 4-channel isolated barrier
- 24 V DC supply (bus powered)
- Analog in or analog out signals
- Sink and source mode outputs
- SMART pass-through
- Up to SIL 2 acc. to IEC 61508
This item is out of production!
2-channel isolated barrier
This item is out of production!
This Item is out of Production!
2-channel, 24 V DC supply, Current output up to 750 Omega- load
- 32-channel
- 24 V DC supply
- HART field device input (revision 5 to 7)
- RS-485 interface
- Up to SIL 3 acc. to IEC 61508
- 32-channel
- 24 V DC supply
- Interface for serial or parallel wiring options
- Dual RS 485 connections
- Slot for HART Multiplexer
- Ideal for retrofitting existing installations
- Interface for serial or parallel wiring options
- 37-pin Sub-D connectors
- Redundant power supply connections
- HART filter options
- Fuse options
- 32-channel
- 24 V DC supply
- For analog output cards
- HART output filters
- Interface for serial or parallel wiring options
- 37-pin Sub-D connectors
- Slot for HART Multiplexer
- TDC 3000 replacement FTA
- Short-circuit protected
- Redundant PCS wirings
- Redundant power supply connections
- Field terminal blocks that are Honeywell FTA compatible
- Honeywell ""B"" size footprint
- Triconex 3700A and 3721 replacement FTA
- 2- or 3-wire or self powered transmitters
- Outputs: 2 x 16 channels, 0 V ... 10 V differential, DC coupled (makes 32 channels)
- Short-circuit protected
- Plug-n-play wiring capabilities
- Triconex 3700A and 3721 replacement FTA
- 2- or 3-wire or self powered transmitters
- Outputs: 2 x 16 channels, 0 V ... 10 V differential, DC coupled (makes 32 channels)
- Short-circuit protected
- Plug-n-play wiring capabilities
- Optimized for use in floating power configurations
- Triconex 3704E and 3720 replacement FTA
- 2- or 3-wire or self powered transmitters
- Outputs: 1 x 32 channels, 0 V ... 5 V differential, DC coupled
- Short-circuit protected
- Plug-n-play wiring capabilities
- Triconex 3805E replacement FTA
- 32 channels of I/O
- Outputs: 4 x 8 channels, 4 mA ... 20 mA current loop, DC coupled
- Short-circuit protected
- HART analog output filters
hm 20 2x 400 c k35
- Supply voltage: 18...30 V DC
- Current consumption: ≤ 12 mA
- Input resistance: ≥ 2 kΩ
- Output resistance: ≤ 100 Ohm
- Response time: ≤ 2 ms
- Protection: IP67
- Interface for wireless communication between PC host and any HART field device
- Registered with HART Communication Foundation
- ATEX and IECEx approval
- UL listed for North America
- Powerful, high-speed Bluetooth with 100 m open-air range
- Adaptive frequency hopping to reduce radio-frequency interference
- HARTCommDTM software supports use with FDT Frame applications
- Compatible with 32- and 64-bit Windows?® 7, 8, XP, 10, or Vista
- HART compliant for communication with any HART field device and error-free slave testing
- Draws power from USB port, needs no external supply to power modem
- Compact, rugged polycarbonate housing for industrial-grade reliability
- Quickly power and communicate with HART field devices
- Powers all 2-wire HART devices, independent of supplier
- Draws power from USB port, needs no external supply to power modem
- Compact, rugged polycarbonate housing for industrial-grade reliability
- Integrated connector cable terminates in 2 test clips and 1 USB connector cable
- Selectable powered-modem or modem-only mode
- Compatible with 32- and 64-bit Windows?® 7, 8, XP, 10, or Vista
hm20 rexroth
- Nominal supply voltage: 12...35 V DC
- Current consumption: max. 20 mA
- Input resistance: max. 220 ohms
- Response time: < 2 ms
Omron Memory Card
art. HMC 1039C
Omron hmc ef183 - Old-Series
HMC16 is a bearingless incremental encoder
- Protection: IP 68 (encoder), IP 65 (signal processing)
- Material: aluminum alloy sensor head housing, stainless steel wheel (1.4104)
- Operating temperature: encoder -20 to +85 °C, signal processing 0 to +50 °C
- Vibration and shock resistance: vibration 25 g, 10-2000 Hz; shock 300 g, 12 ms12.
HMG 11
- Multiturn / SSI / Profibus / CANopen® / DeviceNet / PROFINET
- Optical sensing method
- Singleturn 13 bit, multiturn 12 bit / 16 bit
- Blind or through hollow shaft or cone shaft ø16...20 mm