Baumer Absolute encoders
Voltage supply | 10...30 VDC |
Consumption typ. | 100 mA (24 VDC, w/o load) |
Initializing time typ. | 170 ms after power on |
Operating temperature | -20...+85 °C |
Voltage supply | 10...30 VDC |
Consumption typ. | 100 mA (24 VDC, w/o load) |
Initializing time typ. | 170 ms after power on |
Operating temperature | -20...+85 °C |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption typ. | 100 mA (5 VDC, w/o load) 50 mA (24 VDC, w/o load) |
Initializing time typ. | 170 ms after power on |
Operating temperature | -20...+85 °C |
Inputs | SSI clock Zero setting input |
Voltage supply | 10...30 VDC |
Consumption typ. | 50 mA (24 VDC, w/o load) |
Initializing time typ. | 170 ms after power on |
Interface | 12 parallel outputs |
Operating temperature | -20...+85 °C |
Voltage supply | 10...30 VDC |
Consumption typ. | 100 mA (24 VDC, w/o load) |
Sensing method | Magnetic |
Operating temperature | -20...+85 °C |
Voltage supply | 5 VDC ±10 % |
Consumption typ. | 100 mA (5 VDC, w/o load) |
Sensing method | Magnetic |
Interface | 9 parallel outputs |
Operating temperature | -20...+85 °C |
Voltage supply | 10...30 VDC |
Consumption typ. | 50 mA (24 VDC, w/o load) |
Sensing method | Magnetic |
Interface | 12 parallel outputs |
Operating temperature | -20...+85 °C |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption typ. | 100 mA (5 VDC, w/o load) 50 mA (24 VDC, w/o load) |
Sensing method | Magnetic |
Operating temperature | -20...+85 °C |
Inputs | SSI clock Zero setting input |
Voltage supply | 10...30 VDC |
Consumption typ. | 100 mA (24 VDC, w/o load) |
Initializing time typ. | 500 ms after power on |
Operating temperature | -20...+65 °C |
Voltage supply | 10...30 VDC |
Consumption w/o load | ≤200 mA (24 VDC) |
Initializing time | ≤250 ms after power on |
Operating temperature | -40...+85 °C (see general informations) |
Voltage supply | 10...30 VDC |
Consumption typ. | 50 mA (24 VDC, w/o load) |
Initializing time typ. | 170 ms after power on |
Interface | 12 parallel outputs |
Operating temperature | -20...+85 °C |
Voltage supply | 10...30 VDC |
Consumption w/o load | ≤200 mA (24 VDC) |
Initializing time | ≤250 ms after power on |
Operating temperature | -40...+85 °C (see general informations) |
Voltage supply | 10...30 VDC |
Consumption typ. | 50 mA (24 VDC, w/o load) |
Initializing time typ. | 170 ms after power on |
Interface | 12 parallel outputs |
Operating temperature | -20...+85 °C |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption w/o load | ≤150 mA (5 VDC) ≤60 mA (24 VDC) |
Initializing time typ. | 170 ms after power on |
Operating temperature | -40...+85 °C (see general informations) |
Inputs | SSI clock: Linereceiver RS422 Zero setting input |
Voltage supply: 10...30 VDC
- Absolute encoder multiturn
- Optical sensing method
- Max. resolution: singleturn 18В bit, multiturn 16 bit
- Blind hollow shaft
- LED status display
- EtherCAT
- Maximum resistant against magnetic fields
- Absolute encoder multiturn
- Optical sensing method
- Max. resolution: singleturn 18В bit, multiturn 16 bit
- Blind hollow shaft
- LED status display
- EtherNet/IP
- Maximum resistant against magnetic fields
- Button for Preset/Reset
- Rotary coding switch for IP address
- Absolute encoder multiturn
- Optical sensing method
- Max. resolution: singleturn 18В bit, multiturn 16 bit
- Blind hollow shaft
- LED status display
- PROFINET IO
- Maximum resistant against magnetic fields
- Absolute encoder multiturn
- Optical sensing method
- Max. resolution: singleturn 18В bit, multiturn 16 bit
- Clamping flange
- LED status display
- PROFINET IO
- Maximum resistant against magnetic fields
- Absolute encoder multiturn
- Optical sensing method
- Max. resolution: singleturn 18В bit, multiturn 16 bit
- Synchro flange
- LED status display
- PROFINET IO
- Maximum resistant against magnetic fields
- Absolute encoder multiturn
- Optical sensing method
- Max. resolution: singleturn 18В bit, multiturn 16 bit
- Through hollow shaft
- LED status display
- EtherCAT
- Maximum resistant against magnetic fields
- Absolute encoder multiturn
- Optical sensing method
- Max. resolution: singleturn 18В bit, multiturn 16 bit
- Through hollow shaft
- LED status display
- EtherNet/IP
- Maximum resistant against magnetic fields
- Button for Preset/Reset
- Rotary coding switch for IP address
- Absolute encoder multiturn
- Optical sensing method
- Max. resolution: singleturn 18В bit, multiturn 16 bit
- Through hollow shaft
- LED status display
- PROFINET IO
- Maximum resistant against magnetic fields
- Encoder singleturn / Analog
- Contactless measuring method
- Robust magnetic sensing
- Simple mouting, long service life
- Designed for harsh environmental conditions
- Operating temperature -40...+85 В°C
- Resolution: 12 bit
- Redundant version available
- Protection IP 65 or IP 67
- Encoder singleturn / CANopenВ®
- Contactless measuring method
- Robust magnetic sensing
- Simple mouting, long service life
- Designed for harsh environmental conditions
- Operating temperature -40...+85 В°C
- Resolution 14 bit
- Redundant version available
- Protection IP 65 or IP 67
- Encoder single- or multiturn / CANopenВ®
- Precise magnetic sensing
- Angular accuracy up to В±0.15В°
- High protection up to IP 67
- High resistance to shock and vibrations
- Electronic gear function
- Radial or axial plug and cable connection
- Encoder single- or multiturn / SSI
- Precise magnetic sensing
- Angular accuracy up to В±0.15В°
- Resolution max. 32 bit (14 bit ST, 18 bit MT)
- High resistance to shock and vibrations
- High protection up to IP 67
- Radial or axial plug and cable connection
- Encoder single- or multiturn / SSI
- Precise magnetic sensing
- Angular accuracy up to В±0.15В°
- Resolution max. 32 bit (14 bit ST, 18 bit MT)
- High resistance to shock and vibrations
- High protection up to IP 67
- Radial or axial plug and cable connection
- Encoder single- or multiturn / CANopenВ®
- Precise magnetic sensing
- Angular accuracy up to В±0.15В°
- Additional incremental signals
- High protection up to IP 67
- High resistance to shock and vibrations
- Electronic gear function
- Encoder single- or multiturn / SSI
- Precise magnetic sensing
- Angular accuracy up to В±0.15В°
- Resolution max. 32 bit (14 bit ST, 18 bit MT)
- Additional incremental signals
- Clock frequency up to 2 MHz
- High resistance to shock and vibrations
- High protection up to IP 67