Baumer Absolute encoders

Voltage supply10...30 VDC
Reverse polarity protectionYes
Consumption w/o load≤60 mA (24 VDC)
Operating temperature-25...+85 °C
-40...+85 °C (optional)
Voltage supply10...30 VDC
Reverse polarity protectionYes
Consumption w/o load≤50 mA (24 VDC)
Operating temperature-25...+85 °C
-40...+85 °C (optional)
Voltage supply9...30 VDC
Consumption w/o load≤100 mA (per interface SSI)
≤250 mA (per interface bus)
Initializing time≤200 ms after power on
Operating temperature-20...+85 °C
Voltage supply9...30 VDC
Consumption w/o load≤100 mA (per interface SSI)
≤250 mA (per interface bus)
Initializing time≤200 ms after power on
Operating temperature-20...+85 °C
Blind hollow shaft or cone shaft (1:10)
  • Interface DeviceNet
  • Magnetic sensing method
  • Resolution: singleturn 13 bit, multiturn 16 bit
  • Function display via LEDs
  • Multiturn sensing with Energy Harvesting technology "MicroGen", without gear or battery
  • Two-sided bearing system with hybrid bearings
  • Special protection against corrosion CX (C5-M)
Blind hollow shaft or cone shaft (1:10)
  • Interface EtherCAT
  • Magnetic sensing method
  • Resolution: singleturn 13 bit, multiturn 16 bit
  • Function display via LEDs
  • Multiturn sensing with Energy Harvesting technology "MicroGen", without gear or battery
  • Two-sided bearing system with hybrid bearings
  • Special protection against corrosion CX (C5-M)
  • Magnetic sensing method
  • Function display via LEDs
  • Multiturn sensing with Energy Harvesting technology "MicroGen", without gear or battery
  • Two-sided bearing system with hybrid bearings
  • Special protection against corrosion CX (C5-M)
  • Interface CANopenВ®
  • Magnetic sensing method
  • Resolution: singleturn 13 bit, multiturn 16 bit
  • Function display via LEDs
  • Multiturn sensing with Energy Harvesting technology "MicroGen", without gear or battery
  • Two-sided bearing system with hybrid bearings
  • Special protection against corrosion CX (C5-M)
  • Magnetic sensing method
  • Function display via LEDs
  • Multiturn sensing with Energy Harvesting technology "MicroGen", without gear or battery
  • Two-sided bearing system with hybrid bearings
  • Special protection against corrosion CX (C5-M)
Voltage supply
(Signals)
4.75...30 VDC (5 VDC ±5 % = RS422, 10...30 VDC = HTL)
Consumption w/o load≤50 mA (24 VDC)
Pulses per revolution1024...8192
Operating temperature-40...+85 °C
InputsSSI clock
Zero setting input
Counting direction

Absolute encoder / Singleturn 8...17 Bit / Magnetic sensing / Through hollow shaft max. diam 80 mm

Absolute encoder / Singleturn 8...17 Bit / Magnetic sensing / Through hollow shaft max. 180 mm

Absolute encoder Bearingless / Singleturn 8...17 Bit / Magnetic sensing / Through hollow shaft max. 340 mm

Sensor head with magnetic tape for shaft 300...3183 mm

Voltage supply4.75...30 VDC
Consumption w/o load≤300 mA (24 VDC)
Output signalsSSI data (Linedriver RS485)
Operating temperature-40...+85 °C
  • Interface CANopenВ®
  • Magnetic sensing method
  • Resolution: singleturn 13 bit, multiturn 16 bit
  • Function display via LEDs
  • Multiturn sensing with Energy Harvesting technology "MicroGen", without gear or battery
  • Two-sided bearing system with hybrid bearings
  • Special protection against corrosion CX (C5-M)
  • Magnetic sensing method
  • Function display via LEDs
  • Multiturn sensing with Energy Harvesting technology "MicroGen", without gear or battery
  • Two-sided bearing system with hybrid bearings
  • Special protection against corrosion CX (C5-M)
  • Magnetic sensing method
  • Function display via LEDs
  • Multiturn sensing with Energy Harvesting technology "MicroGen", without gear or battery
  • Two-sided bearing system with hybrid bearings
  • Special protection against corrosion CX (C5-M)
Voltage supply10...30 VDC
Reverse polarity protectionYes
Consumption w/o load≤50 mA (24 VDC)
Operating temperature-25...+60 °C
Voltage supply10...30 VDC
Reverse polarity protectionYes
Consumption w/o load≤100 mA (24 VDC)
Operating temperature-25...+60 °C
Voltage supply10...30 VDC
5 VDC ±10 %
Reverse polarity protectionYes
Consumption w/o load≤50 mA (24 VDC)
Operating temperature-25...+60 °C
InputsSSI clock
Control signals UP/DOWN and zero