Baumer Absolute encoders
HDmag MHAP 200
- Sensor head: FPGA signal processing
- Type: Absolute encoder
- Resolution: 8...17 bits (single rotary)
- Maximum diameter of the hollow shaft: 180 mm
MHAP 400 - HDmag
- Absolute encoder with magnetic sensing and without bearings
- Sensor head with integrated FPGA signal processing
- Absolute resolution max. 17 bit singleturn
- Additional incremental output
- Electronics is fully encapsulated
- Large tolerances: axial ±1 mm, radial max. 0.5 mm
- Simple mounting, easy adaptation
Sensor head with magnetic tape for shaft 300...3183 mm
- Position resolution (Singleturn): up to 20 bits.
- Speed resolution: up to 18 bits.
- Output signals: SSI.
- Input for setting the zero position and selecting the direction of rotation.
- Status indication: via System OK output and LED.
- Large mounting tolerances.
Baumer X 700 - CANopen®
- Encoder multiturn / CANopen® / ATEX
- Optical sensing method
- Resolution: singleturn 18 bit, multiturn 14 bit
- Clamping flange with solid shaft ø10 mm
- Explosion protection per Ex II 2D/2G (ATEX)
- Device class 2 / zone 1 (gas), zone 21 (dust)
Baumer X 700 - Profibus
- Encoder multiturn / Profibus / ATEX
- Optical sensing method
- Resolution: singleturn 13 bit, multiturn 16 bit
- Clamping flange with solid shaft ø10 mm
- Explosion protection per Ex II 2D/2G (ATEX)
- Device class 2 / zone 1 (gas), zone 21 (dust)
Baumer X 700 - SSI Multiturn
- Encoder multiturn / SSI / ATEX
- Optical sensing method
- Resolution: multiturn 13 + 12 bit
- Clamping flange with solid shaft ø10 mm
- Explosion protection per Ex II 2D/2G (ATEX)
- Device class 2 / zone 1 (gas), zone 21 (dust)
Voltage supply | +UB= 12...30 VDC (IS-/IE-/US-/UT-version) -UB= -12...-26 VDC / +UB 12...30 VDC (UE-/UR-version) |
Reverse polarity protection | Yes |
Consumption w/o load | ≤70 mA (24 VDC) |
Operating temperature | -20...+85 °C |
art. 11129466
art. 11223024
Size | 58 mm |
Voltage supply | 8 ... 30 VDC / 14 ... 30 VDC |
Operating temperature | –40 ... +85 °C |
art. 11125617
Baumer absolute encoder XMMS.W203EA2 with singleturn resolution 13 bit and multiturn 16 bit.
art. 11088324
PROFIBUS DPV2/CONNECTOR M12 MT
art. 11197171
Solid shaft encoder with EURO flange B10, PMG10 series. art. 11197171
Absolute encoders AMG 81
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption typ. | 120 mA (5 VDC, w/o load) 70 mA (24 VDC, w/o load) |
Initializing time typ. | 170 ms after power on |
Interface | 12 parallel outputs |
Operating temperature | -20...+85 °C |
Voltage supply | 10...30 VDC |
Consumption w/o load | ≤80 mA (24 VDC) |
Initializing time typ. | 500 ms after power on |
Operating temperature | -40...+85 °C (see general informations) |
Voltage supply | 10...30 VDC |
Consumption typ. | 100 mA (24 VDC, w/o load) |
Initializing time typ. | 170 ms after power on |
Operating temperature | -20...+85 °C |
Voltage supply | 10...30 VDC |
Consumption w/o load | ≤200 mA (24 VDC) |
Initializing time | ≤250 ms after power on |
Operating temperature | -40...+85 °C (see general informations) |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption w/o load | ≤150 mA (5 VDC) ≤60 mA (24 VDC) |
Initializing time typ. | 170 ms after power on |
Operating temperature | -40...+85 °C (see general informations) |
Inputs | SSI clock: Linereceiver RS422 Zero setting input |
Voltage supply | 10...30 VDC |
Consumption typ. | 50 mA (24 VDC, w/o load) |
Initializing time | ≤170 ms after power on |
Operating temperature | -40...+85 °C |
Inputs | SSI clock Zero setting input |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption typ. | 100 mA (5 VDC, w/o load) 50 mA (24 VDC, w/o load) |
Initializing time typ. | 70 ms after power on |
Operating temperature | -20...+85 °C |
Inputs | SSI clock Zero setting input |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption typ. | 100 mA (5 VDC, w/o load) 50 mA (24 VDC, w/o load) |
Initializing time typ. | 70 ms after power on |
Operating temperature | -40...+65 °C |
Inputs | SSI clock Zero setting input |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption typ. | 100 mA (5 VDC, w/o load) 50 mA (24 VDC, w/o load) |
Initializing time typ. | 170 ms after power on |
Operating temperature | -20...+85 °C |
Inputs | SSI clock Zero setting input |
Voltage supply | 8...30 VDC |
Reverse polarity protection | Yes |
Short-circuit proof | Yes |
Operating temperature | -40...+85 °C |
Voltage supply | 10...30 VDC |
Consumption w/o load | ≤80 mA (24 VDC) |
Initializing time typ. | 500 ms after power on |
Operating temperature | -40...+85 °C (see general informations) |
Voltage supply | 10...30 VDC |
Consumption typ. | 100 mA (24 VDC, w/o load) |
Initializing time typ. | 500 ms after power on |
Operating temperature | -20...+65 °C |
Voltage supply | 10...30 VDC |
Consumption w/o load | ≤200 mA (24 VDC) |
Initializing time | ≤250 ms after power on |
Operating temperature | -40...+85 °C (see general informations) |
Voltage supply | 10...30 VDC |
Consumption typ. | 100 mA (24 VDC, w/o load) |
Initializing time typ. | 170 ms after power on |
Operating temperature | -40...+85 °C |
Voltage supply | 10...30 VDC |
Consumption typ. | 100 mA (24 VDC, w/o load) |
Initializing time typ. | 170 ms after power on |
Operating temperature | -40...+85 °C |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption w/o load | ≤150 mA (5 VDC) ≤60 mA (24 VDC) |
Initializing time typ. | 170 ms after power on |
Operating temperature | -40...+85 °C (see general informations) |
Inputs | SSI clock: Linereceiver RS422 Zero setting input |
Voltage supply | 5 VDC ±10 % 10...30 VDC |
Consumption typ. | 100 mA (5 VDC, w/o load) 50 mA (24 VDC, w/o load) |
Initializing time typ. | 70 ms after power on |
Operating temperature | -20...+85 °C |
Inputs | SSI clock Zero setting input |