Turbidity Analysis Sensor

Compact system with sample condition adjustment for drinking and process water applications.

Turbidity Analysis Sensor

Compact system with sample condition adjustment for drinking and process water applications.

Turbidity Analysis Sensor
Turbidity Analysis Sensor

Turbidity Analysis Sensor

Handheld meter for on-site quality control in drinking and process water applications.

Turbidity Analysis Sensor

Handheld meter for on-site quality control in drinking and process water applications.

Turbidity Analysis Sensor

Measurement range

40 to 4 000 FAU
0 to 60 g/L suspended solids
0 to 10 OD

Process temperature

Process temperature -20 to 85 В°C (-4 to 185 В°F)
Ambient temperature -20 to 60 В°C (-4 to 140 В°F)

Process pressure

0.5 to 4.5 bar (7.3 to 65.3 psi) absolute

Turbidity Analysis Sensor

Measurement range

For formazin: 0 to 4000 FNU
Display range up to 9999 FNU
For sludge: 0 to 300 g/L
The achievable measuring range depends very much on the media

Process temperature

Process temperature:
-5 to 50 В°C (23 to 122 В°F)
Ambient temperature:
-20 to 60 В°C (-4 to 140 В°F)

Measurement range

0.000 to 4000 FNU

Process temperature

Stainless steel version: -20 to 85 В°C (0 to 185 В°F)
Plastic version: -20 to 60В°C (-4 to 140 В°F)

Process pressure

Stainles steel version: 0.5 to 10 bar abs
(7.3 to 145 psi abs)
Plastic version: 0.5 to 6 bar abs
(7.3 to 87 psi abs)

TURBIMAX-W CUS65 Suspended solid / turbidity sensor Four Beam Pulsed Light Method 880 nm. Sensor body ss 316 Ti, operating temperature 0 to 50 oC

Complete ultrasonic bed level measuring point

Integral and immersion sensor
Turbidity Analysis Sensor

Protective tube thermowell

Max. process pressure (static)

50 bar (725 psi)

Maximum standard immersion length

4.000 mm (157,48")

Max. immersion length on request

10.000 mm (393,7")

Protective tube thermowell

Max. process pressure (static)

50 bar (725 psi)

Maximum standard immersion length

4.000 mm (157,48")

Max. immersion length on request

10.000 mm (393,7")

Protective tube thermowell

Max. process pressure (static)

50 bar (725 psi)

Maximum standard immersion length

4.000 mm (157,48")

Max. immersion length on request

10.000 mm (393,7")

Protective tube thermowell

Max. process pressure (static)

50 bar (725 psi)

Maximum standard immersion length

4.000 mm (157,48")

Max. immersion length on request

10.000 mm (393,7")

Solid-machined thermowell

Max. process pressure (static)

400 bar (5802 psi)

Maximum standard immersion length

250 mm (9,84")

Max. immersion length on request

400 mm (15,75")

Protective tube thermowell

Max. process pressure (static)

50 bar (725 psi)

Maximum standard immersion length

4.000 mm (157,48")

Max. immersion length on request

10.000 mm (393,7")

Protective tube thermowell

Cast thermowell

Max. process pressure (static)

1 bar (15 psi)

Maximum standard immersion length

1.500 mm (59,06")

Max. immersion length on request

4.000 mm (157,48")

Max. process pressure (static)

1 bar (15 psi)

Maximum standard immersion length

2.200 mm (86,61")

Max. immersion length on request

4.525 mm (178,15")

Mortise fittings

Process temperature

max. 140В°C

Process pressure

max. 10bar

Process temperature

-15 to 140 В°C (5 to 280 В°F)

Process pressure

16 bar up to 140 В°C (232 psi up to 284 В°F)

Liquid nitrate analyzer

Measurement range

0.01 to 20 mg/l / 0.1 to 50 mg/l NO3-N
0.04 to 80 mg/l / 0.4 to 200 mg/l NO3
0.1 to 50 1/m / 0.5 to 250 1/m / 1.5 to 700 1/m SAC
0.15 to 75 mg/l / 0.75 to 370 mg/l / 2.5 to 1000 mg/l COD (254nm)
0.06 to 30 mg/l / 0.3 to 150 mg/l / 0.9 to 410 mg/l TOC (254nm)

Process temperature

5 to 50В°C (41 to 120 В°F)

Accuracy

pn ≥ 400mbar: 0.35 %
pn < 400mbar: 0.50 %

Process temperature

-10В°C...+70В°C
(+14В°F...+158В°F)

Pressure measuring range

200 mbar...2 bar
(3 psi...29 psi)

Process pressure absolute / max. overpressure limit

10 bar (145 psi)

Main wetted parts

316L

Max. measurement distance

200 m H2O
(656 ft H2O)

Material process membrane

Metal

Measuring cell

200 mbar...2 bar
(3 psi...29 psi)

Hydrostatic pressure sensor

Pressure and level transmitter

Accuracy

0.2%
0.1% (optional)

Process temperature

-10В°C...70В°C
(14В°F...158В°F)
Diameter 29 mm (1.14"): 0В°C...50В°C
(32В°F...122В°F)