Endress+Hauser

Choose a subcategory:
Show all categories
Field display
Digital panel display
Input

2 x universal (U, I, R, RTD, TC)

Output

2 x analogue output (I, U) 1 x loop power supply

Output

2 x analogue output (I, U)
1 x loop power supply

Display

Multicolor backlight LCD
White/black/yellow
Bargraph
Unit
TAG
Alarm warning in plain text

Power Supply

20...250V AC/DC

Input

NAMUR
blocking: < 1,2 mA
conducting: > 2,1 mA

Output

relay contact

Power Supply

24 V DC

Secondary signal converter

Input

2 x universal (current, voltage, R, RTD, TC, resistance)

Output

2 x Analog (current, voltage)

Output

2 x Analog (current, voltage)

Display

LCD
7 segment
Multicolour
Bargraph
TAG unit
Colour change in case of failure

Power Supply

Not defined

Universal Energy manager and flow calculator

Calculations

mass/heat quantity
heat quantity difference
for gases: standard volume, heating value, mass

Application manager

Input

2...6x RTD
2...8x I
2...8x PFM
2...8x Impulse (aktive)
2...8x Impulse (passive)

Output

3...9x transmitter power supply

Display

Dot-Matrix LCD, backlit, colour change in case of alarm event

Calculations

heat quantity
heat quantity difference

Input

0/4...20 mA / HART
feeding/not feeding

Output

0/4...20 mA / HART
active/passive

Power Supply

24 V DC

Input

0/4...20 mA / HART
feeding/not feeding

Output

0/4...20 mA / HART
active/passive

Power Supply

20...250 V AC/DC

Output

24 VDC, 1,5 A

Power Supply

100...240 V AC (wide range power supply)
45...65 Hz

Output

24...28 V DC

Power Supply

100...240 V AC/DC

Input

24 V DC

Output

Uin - 0,8 V

Power Supply

24 V DC

Input

0/4...20 mA / HART
passive

Output

0/4...20 mA / HART
active

Power Supply

24 V DC

Functions

Stationary samplesr

Suction height

6 m (19,69 ft) suction height
8 m (26,25 ft)

Cabinet

tainless steel

Input

1 x analog (U, I)

Output

1 x transmitter power supply

Output

1 x transmitter power supply

Display

LCD 6 mm (0.24")
4-digit
Bargraph

Power Supply

Not defined

Process temperature

0 - 50В°C

Process pressure

up to 6 bar

Capacitive level transmitter
Accuracy

+/- 2.5 cm (0.98")

Process temperature

-20В°C ... +150В°C
(-4В°F...302В°F)

Process pressure absolute / max. overpressure limit

0.8 ... 1.1 bar
(11.6psi...15.95psi)

Max. measurement distance

32m (105ft)

Main wetted parts

Aluminium, Steel, Stainless steel

Accuracy

+/- 5 cm

Process temperature

-20В°C ... +230В°C
(-4В°F ... 446В°F)

Process pressure absolute / max. overpressure limit

0.8 ... 3 bar
(11.6psi...43.5psi)

Max. measurement distance

70m (230ft)

Main wetted parts

Aluminium, Steel, Stainless steel

Measurement range

200 ВµS/cm to 1000 mS/cm
Cell constant k: 11.0 1/cm

Process temperature

-10 В°C to 110 В°C (14 В°F to 230 В°F)
Sterilization: max. 130 В°C at 6 bar abs up to 60 min
(Max. 266 В°F at 87 psi up to 60 min)

Process pressure

13 bar abs up to 50 В°C (188.5 psi up to 122 В°F)
7.75 bar abs at 110 В°C (112 psi at 230 В°F)
6.0 bar abs at 130 В°C for max. 60 minutes
(87 psi at 266 В°F for max. 60 minutes)

Capacitive level transmitter

Capacitive level transmitter