Endress+Hauser

Choose a subcategory:
Show all categories

Application manager

Input

2...6x RTD
2...8x I
2...8x PFM
2...8x Impulse (aktive)
2...8x Impulse (passive)

Output

3...9x transmitter power supply

Display

Dot-Matrix LCD, backlit, colour change in case of alarm event

Calculations

heat quantity
heat quantity difference

Input

0/4...20 mA / HART
feeding/not feeding

Output

0/4...20 mA / HART
active/passive

Power Supply

24 V DC

Input

0/4...20 mA / HART
feeding/not feeding

Output

0/4...20 mA / HART
active/passive

Power Supply

20...250 V AC/DC

Output

24 VDC, 1,5 A

Power Supply

100...240 V AC (wide range power supply)
45...65 Hz

Output

24...28 V DC

Power Supply

100...240 V AC/DC

Input

24 V DC

Output

Uin - 0,8 V

Power Supply

24 V DC

Input

0/4...20 mA / HART
passive

Output

0/4...20 mA / HART
active

Power Supply

24 V DC

Functions

Stationary samplesr

Suction height

6 m (19,69 ft) suction height
8 m (26,25 ft)

Cabinet

tainless steel

Input

1 x analog (U, I)

Output

1 x transmitter power supply

Output

1 x transmitter power supply

Display

LCD 6 mm (0.24")
4-digit
Bargraph

Power Supply

Not defined

Process temperature

0 - 50В°C

Process pressure

up to 6 bar

Capacitive level transmitter
Accuracy

+/- 2.5 cm (0.98")

Process temperature

-20В°C ... +150В°C
(-4В°F...302В°F)

Process pressure absolute / max. overpressure limit

0.8 ... 1.1 bar
(11.6psi...15.95psi)

Max. measurement distance

32m (105ft)

Main wetted parts

Aluminium, Steel, Stainless steel

Accuracy

+/- 5 cm

Process temperature

-20В°C ... +230В°C
(-4В°F ... 446В°F)

Process pressure absolute / max. overpressure limit

0.8 ... 3 bar
(11.6psi...43.5psi)

Max. measurement distance

70m (230ft)

Main wetted parts

Aluminium, Steel, Stainless steel

Measurement range

200 ВµS/cm to 1000 mS/cm
Cell constant k: 11.0 1/cm

Process temperature

-10 В°C to 110 В°C (14 В°F to 230 В°F)
Sterilization: max. 130 В°C at 6 bar abs up to 60 min
(Max. 266 В°F at 87 psi up to 60 min)

Process pressure

13 bar abs up to 50 В°C (188.5 psi up to 122 В°F)
7.75 bar abs at 110 В°C (112 psi at 230 В°F)
6.0 bar abs at 130 В°C for max. 60 minutes
(87 psi at 266 В°F for max. 60 minutes)

Capacitive level transmitter

Capacitive level transmitter

Process temperature

-50В°C ... 400В°C
(-58В°F ... 752В°F)

Process pressure absolute / max. overpressure limit

Vacuum ... 10 bar
(Vacuum ... 145 psi)

Process temperature

Non-contact installation: any
Within installation:
20 В°C ... +60 В°C (4 В°F ... +140 В°F)
With HT-Adapter:
up to +450 В°C (+842 В°F)

Process pressure absolute / max. overpressure limit

Non-contact installation: any
Within installation:
0.5 bar ... 6.8 bar (7.2 psi ... 99 psi) abs.
With HP-Adapter:
up to +21 bar (+305 psi) abs.

Min. density of medium

Solid weight: > 10 g/l

Process temperature

Standard
-40В°C ... +70В°C
(-40В°F ...158В°F)
With adapter for temperature reduction:
-40В°C to +450В°C
-40В°F ...+842В°F)

Process pressure absolute / max. overpressure limit

0.5 ... 6.8 bar abs standard
(7.2 ... 98.6 psi abs)
When using the adapter for temperature reduction:
0.8 to 5.1 bar abs
(11.6 ...74 psi abs)

Vibrating point level switch

Vibrating point level switch

Vibrating point level switch

Vibrating point level switch

Vibrating point level switch

Flag level limit switch