Endress+Hauser

Choose a subcategory:
Show all categories
Liquid PH and ORP analysis sensor
Liquid PH and ORP analysis sensor

Resistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration

Max. process pressure (static)

at 20 В°C: 75 bar (1088 psi)

Operating temperature range

PT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

Resistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration

Max. process pressure (static)

at 20 В°C: 75 bar (1088 psi)

Operating temperature range

PT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

Resistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration

Max. process pressure (static)

at 20 В°C: 40 bar (580 psi)

Operating temperature range

PT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

Resistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration

Max. process pressure (static)

at 20 В°C: 50 bar (725 psi)

Operating temperature range

PT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

Tesistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration

Max. process pressure (static)

at 20 В°C: 400 bar (5.802 psi)

Operating temperature range

PT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)

Max. immersion length on request

up to 30.000,00 mm (1.181,10'')

Resistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration
t50 = 2 s
t90 = 5 s

Max. process pressure (static)

at 20 В°C: 40 bar (580 psi)

Operating temperature range

PT 100:
-200 В°C ...500 В°C
(-328 В°F ...932 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

Resistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration
t50 = 2 s
t90 = 5 s

Max. process pressure (static)

at 20 В°C: 40 bar (580 psi)

Operating temperature range

PT 100:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

Tesistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration
t50 = 8 s
t90 = 21 s

Max. process pressure (static)

at 20 В°C: 100 bar (1.450 psi)

Operating temperature range

PT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

Tesistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration
t50 = 4 s
t90 = 8 s

Max. process pressure (static)

at 20 В°C: 500 bar (7.252 psi)

Operating temperature range

PT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)

Max. immersion length on request

up to 30.000,00 mm (1.181,10'')

Tesistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration
t50 = 4 s
t90 = 8 s

Max. process pressure (static)

at 20 В°C: 100 bar (1.450 psi)

Operating temperature range

PT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)

Max. immersion length on request

up to 10.000,00 mm (393,70'')

Tesistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

t50 = 2 s
t90 = 5 s

Max. process pressure (static)

at 20 В°C: 80 bar (1.160 psi)

Operating temperature range

PT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)

Max. immersion length on request

up to 30.000,00 mm (1.181,10'')

Tesistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration

Max. process pressure (static)

at 20 В°C: 500 bar (7.252 psi)

Operating temperature range

PT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)

Max. immersion length on request

up to 5.000,00 mm (196,85'')

Tesistance thermometer

Accuracy

class A acc. to IEC 60751
class AA acc. to IEC 60751

Response time

depending on configuration

Max. process pressure (static)

depending on Thermowell

Operating temperature range

PT100 TF StrongSens:
-50 В°C ...500 В°C
(-58 В°F ...932 В°F)
PT100 WW:
-200 В°C ...600 В°C
(-328 В°F ...1.112 В°F)
PT100 TF:
-50 В°C ...400 В°C
(-58 В°F ...752 В°F)

Max. immersion length on request

up to 30.000,00 mm (1.181,10'')

Process temperature

-40 В°C ... 150 В°C
(-40 В°F ... 302 В°F)

Process pressure absolute / max. overpressure limit

Vacuum ... 30 bar
(Vacuum ... 435 psi)

Min. conductivity of medium

20 ВµS/cm

Compact thermocouple

Accuracy

class 2 acc. to IEC 60584

Response time

t50 = 1 s
t90 = 2 s

Max. process pressure (static)

at 20 В°C: 25 bar (363 psi)

Operating temperature range

Type K:
-40 В°C ...1.100 В°C
(-40 В°F ...2.012 В°F)
Type J:
-40 В°C ...750 В°C
(-40 В°F ...1.382 В°F)

Max. immersion length on request

up to 100.000,00 mm (3.937,01'')

Temperature measuring device, compact. 3-A standard, surface finish: Ra min. 32 micro inch (150 grit). Transmitter: loop powered 4-20mA. Pt100, class A sensor.

Easytemp TSM470G,RTD-Transm.U.S Style Temperature measuring device, compact. Transmitter: loop powered 4-20mA. Pt100, class A sensor. M12 quick connector.


Easytemp TSM470P,RTD-Transm.U.S.Style Temperature measuring device, compact. 3-A standard, surface finish: Ra min. 20 micro inch (240 grit).

Response time: t50 = 3 s; t90 = 6 s

Max. process pressure (static): at 20 В°C: 25 bar (363 psi)

Max. immersion length on request: up to 10.000,00 mm (393,70'')

Accuracy

class A acc. to IEC 60751
class B acc. to IEC 60751

Max. process pressure (static)

at 20 В°C: 1 bar (15 psi)

Operating temperature range

PT 100:
-30 В°C ...100 В°C
(-22 В°F ...212 В°F)